syringe filter Articles

  • The productive environmental laboratory: BSK Labs boosts efficiency with Metrohm IC

    BSK Labs runs a number of environmental laboratories and service centers along the west coast of the US. A total of 70 employees – including microbiologists, chemists, lab technicians, and support staff – make sure that the 200 to 350 samples that come in every week are analyzed. BSK Labs specializes in potable water chemistry, ground water monitoring, storm water runoff, solid waste ...


    By Metrohm AG

  • Detection of atrazine and 2,4-d in raw milk

    MATRIX: Raw Milk ANALYTES: Atrazine, 2,4-D RANGE OF DETECTION: Atrazine: 5 to 250 ppb, 2,4-D: 0.05 to 2.5 ppm MATERIALS: RaPID Assay, Kit and Sample Diluent for Atrazine and 2,4-D Reagents: methanol (pesticide grade), glacial acetic acid, distilled or deionized water, diatomacoeus earth (Celite 545). Equipment: ...


  • Chromatography Tips

    No.1 Gas Chromatography Tips  Our Founders and engineers of the company had accumulated more than 60 years experience in the research and development of HPLC instrumentation; HPLC column technology; mass spectrometer installation, training and services; chemical and biochemical separation, detection and quantification, Proteomics and cancer biomarker research and ...


    By AcuTech Scientific Inc.

  • Asbestos in cigarettes

    The original version of the Kent Micronite cigarette filter used crocidolite, a form of asbestos, from 1952 until at least mid-1956. Cigarettes from intact, unopened packs of the brand from this period were examined. One filter contained approximately 10 mg of crocidolite. Crocidolite structures were found in the mainstream smoke from the first two puffs of each cigarette smoked. At the observed ...


    By Queensland Laboratory

  • Detection of carbaryl in soil

    MATRIX: Soil ANALYTE: Carbaryl RANGE OF DETECTION: 40 to 500 ppb MATERIALS: SDI Carbaryl RaPID AssayÒ kit and Sample Diluent. SDI RaPID PrepÔ Soil Collection Kit (optional). SDI RaPID PrepÔ Extraction Kit: Type II (extraction solution, optional) Reagents: Methanol (pesticide grade), distilled or ...


  • Detection of captan in soil

    MATRIX: Soil ANALYTE: Captan RANGE OF DETECTION: 8 to 300 ppm MATERIALS: Captan RaPID Assay, Kit and Sample Diluent. Reagents: acetone (pesticide grade) Equipment: reciprocating shaker, plastic bottles (polypropylene or high density polyethylene, 50 or 60 mL) with plastic lined screw caps, filtration apparatus (funnel and ...


  • Detection of 2,4-D in soil

    MATRIX: Soil ANALYTES: 2,4-D RANGE OF DETECTION: 150 ppb to 7.5 ppm MATERIALS: 2,4-D RaPID AssayÒ Kit and Sample Diluent Reagents: methanol (pesticide grade), distilled or deionized water, glacial acetic acid. Equipment: reciprocating shaker, plastic bottles (polypropylene or high density polyethylene, 50 or 60 mL) ...


  • Detection of carbendazim in soil

    MATRIX: Soil ANALYTE: Carbendazim, a metabolite of benomyl RANGE OF DETECTION: 37.5 to 750 ppb MATERIALS: Benomyl/Carbendazim RaPID Assay kit and Sample Diluent Reagents: methanol (pesticide grade), sodium hydroxide (ACS grade), distilled or deionized water. Equipment: reciprocating shaker, plastic bottles ...


  • Detection of pentachlorophenol in soil

    MATRIX: Soil ANALYTES: Pentachlorophenol (PCP) RANGE OF DETECTION: 100 ppb to 10 ppm MATERIALS: Pentachlorophenol RaPID AssayÒ kit and Sample Diluent Reagents: methanol (reagent grade), sodium hydroxide (ACS grade), distilled or deionized water. Equipment: reciprocating shaker, plastic bottles (polypropylene or ...


  • Detection of atrazine, alachlor, cyanazine and metolachlor in soil

    MATRIX: Soil ANALYTES: Atrazine, Alachlor, Cyanazine, and Metolachlor RANGE OF DETECTION: Atrazine: 15-750 ppb Alachlor: 15-750 ppb Cyanazine: 15-450 ppb Metolachlor: 15-750 ppb MATERIALS: RaPID Assay Kit and Sample Diluent Reagents: methanol (pesticide grade), distilled or deionized water. ...


  • Detection of carbofuran in soil

    MATRIX: Soil ANALYTE: Carbofuran RANGE OF DETECTION: 10 to 500 ppb MATERIALS: Carbofuran RaPID AssayÒ kit and Sample Diluent. Reagents: methanol (pesticide grade), distilled or deionized water. Equipment: reciprocating shaker, plastic bottles (polypropylene or high density polyethylene, 50 or 60 mL) with ...


  • Real-time TOC tightens effluent control at Greencore

    A food manufacturing facility in Selby has installed a new continuous TOC (Total Organic Carbon) monitor, ‘the BioTector’ which has dramatically improved the site’s capability to refine and improve the plant’s wastewater treatment process. As a result the plant is better able to quickly respond to changes in the influent. Greencore Foods is a leading player in the food ...


  • Detecting Mercury in Water

    Determination of Mercury (Hg) in Water by Hand-Held, Portable Cold Vapor Atomic Fluorescence SpectrometryWater is the most familiar and most abundant compound on Earth, making up 71% of its surface area.[1]It is a vital component for all known forms of life and is the aquatic habitat for thousands of species of microalgae, fish and shellfish. [2] With the presence of running water in our ...


    By Arizona Instrument LLC