tph analyzer Articles

  • On-Site TPH in Soil Measurements

    On-site analysis of total petroleum hydrocarbon (TPH) concentration levels in soil are easily handled using the InfraCal TOG/TPH Analyzers manufactured by Wilks Enterprise, Inc.  The InfraCal TOG/TPH Analyzers are portable infrared (IR) analyzers that quickly determine TPH levels in less than 10-15 minutes, including the extraction.  Concentrations as low as 10 ppm to well over 10,000 - ...


    By Spectro Scientific

  • Bioremedation and TPH analysis at Lumwana Copper Mine in Zambia

    MINING SITE: Equinox Minerals operates the biggest copper mine in Africa located at Lumwana in Northwest province Zambia.  Open pit mining methods are used to access the ore which is hauled to the process plant where it is crushed and processed into final concentrate. The mine operates a large fleet of equipment, including 27 EH4500 dump trucks, 5 shovels, 4 excavators ...


    By Sitelab Corporation

  • Case study - TPH Oil & Grease applications

    These case studies illustrate the performance generated from customers who have used Sitelab’s UVF-3100 analyzer for testing total petroleum hydrocarbons in the C10 to C50 range. Sitelab’s TPH-Oil calibration kit is designed to correlate well to laboratory “Oil and Grease” test methods. This includes EPA Methods 1664 and 9071B by Gravimetric, EPA Method 418.1 by Infrared ...


    By Sitelab Corporation

  • On-Site TPH in Soil Measurements in less than 15 Minutes with Portable IR Analyzers

    On-site analysis of total petroleum hydrocarbon (TPH) concentration levels in soil are easily handled using the InfraCal TOG/TPH Analyzers manufactured by Wilks Enterprise, Inc.  The InfraCal TOG/TPH Analyzers are portable infrared (IR) analyzers that quickly determine TPH levels in less than 10-15 minutes, including the extraction.  Concentrations as low as 10 ppm to well over 10,000 - ...


    By Spectro Scientific

  • Comply with Highly Regulated Oil in Water Measurements Using Portable Infrared Analyzers

    The Petroleum Industry – both offshore and onshore -- has regulations that limit the amount of oil in discharged water.  Fixed filter infrared (IR) analyzers have been used to test oil levels in produced water on drilling platforms for over 45 years for a number of reasons. On oil rigs where real estate is at a premium, infrared analyzers such as the Wilks InfraCal TOG/TPH ...


    By Spectro Scientific

  • Comply with Permit Levels for Fats, Oil and Grease in Wastewater using Portable IR Analyzers

    Wilks InfraCal TOG/TPH Analyzers provide accurate, on-site analysis to help regulators and industry reduce the discharge of fats, oil and grease in wastewater.  On-site testing with the portable mid-IR InfraCal Analyzer gives results in 10 minutes and eliminates the wait for off-site lab results.  It is simple enough for an operator with minimal training to do the analysis. Stricter ...


    By Spectro Scientific

  • Portable Infrared Analyzers Provide On-Site Measurement of Oil and Grease Levels in Hydraulic Fracturing Water

    The amount of water used in and produced by hydraulic fracturing of shale gas wells is in the millions of gallons per well.  Whether the water is going to be taken off-site for disposal or reused for re-injection, the flowback or produced water needs pretreatment to remove any residual oil from the water.  Waiting for remote laboratory results to determine the oil level can take several ...


    By Spectro Scientific

  • Portable IR Analyzers Provide Petroleum & Wastewater Industries with Accurate Oil Content Measurements

    Fixed filter infrared (IR) analyzers have been used to test oil levels in produced water on off-shore and on-shore drilling platforms for well over 45 years. U.S. EPA methods 418.1 and 413.2 were used extensively on a worldwide basis until the Montreal Protocol called for Freon (the solvent used in the analysis) to be phased out. Infrared analysis using tetrachloroethylene (perchloroethylene) is ...


    By Spectro Scientific

  • Determination of Total Petroleum Hydrocarbons in Soil, Sediment, and Waste Samples using the SpeedExtractor E-916

    Total petroleum hydrocarbons (TPH) are a family of several hundred chemical compounds made from crude oil. TPH are found in soils and water. Exposure to TPH can affect human health and, therefore many laboratories around the world are analyzing TPH levels in the environment. This application note describes the extraction of TPH from soil, sediment, and waste samples using the SpeedExtractor ...


    By BÜCHI Labortechnik AG

  • Residential spill in VA

    Laboratory analysis of soil samples showed high values of TPH/DRO showing an initial value of 18,800 and 8,300 ppm and the samples of soil analyzed after treatment with VaporRemed showed a value of 290 ppm and 210 ppm. Both these values are below the stipulated 500 ppm of TPH/DRO. The TPH in the drain water after flushing with the product showed values below the detection levels. The project was ...


    By Sarva Bio Remed, LLC

  • Oil in frac water testing

    The amount of water used in and produced by hydraulic fracturing of shale gas wells is in the millions of gallons per well. Whether the water is going to be taken off site for disposal or reused for re-injection, the flowback or produced water needs pretreatment to remove any residual oil from the wa-ter. Waiting for remote laboratory results can take several days to a week. The InfraCal TOG/TPH ...


    By Spectro Scientific

  • Case study: EPA region 9

    ISTR Overview Neighborhood: Industrial Heating Tubes: 14 Target Temp: 325 ˚C Heating Period: 130 Days Target: 0.9 mg/kg for Benzene Contaminant: TPH-d TPH-mo Benzene Naphthalene BaP Geology: ...

  • Case study - EPH in soil evaluation study at tank farm site

    Ambient Engineering, Inc. (Concord, MA) used Sitelab to investigate and remediate a former tank farm along Boston Harbor contaminated by a large, subsurface plume of commingled diesel fuel and No. 6 fuel oil. Ambient’s Licensed Site Professional (LSP) had the opportunity – and budget – to evaluate Sitelab against three certified laboratories. Soil samples were collected from ...


    By Sitelab Corporation

  • Monitoring of petroleum hydrocarbon degradative potential of indigenous microorganisms in ozonated soil

    This study was performed to investigate the petroleum hydrocarbon (PH) degradative potential of indigenous microorganisms in ozonated soil to better develop combined pre-ozonation/bioremediation technology. Diesel-contaminated soils were ozonated for 0–900min. PH and microbial concentrations in the soils decreased with increased ozonation time. The greatest reduction of total PH (TPH, 47.6%) and ...


    By Springer

  • Accurately Measure Hydrocarbon (Oil/Grease) Levels in Produced Water in Under 15 Minutes

    Determining total hydrocarbon or oil/grease levels to ensure compliance with regulatory permit requirements for discharging produced water is a worldwide problem facing the oil and gas industry.   Ensuring compliance with these regulations and avoiding fines for non-compliant discharges requires more frequent wastewater measurements to determine the total hydrocarbon ...


    By Spectro Scientific

  • Infrared Analysis Reduces Regulatory Fats, Oil and Grease (FOG) Testing Costs and Provides Fast Results

    Wastewater professionals who are enforcing industrial effluent standards for fats, oil and grease (FOG) either must perform numerous gravimetric tests or spend a considerable amount of money with a contracted testing laboratory.  Infrared analysis. using portable instruments such as the InfraCal TOG/TPH Analylzers -provides an alternative which will significantly reduce costs and ...


    By Spectro Scientific

  • Enhanced Aerobic Bioremediation of Petroleum UST Releases in Puerto Rico.

    Abstract: Releases of petroleum compounds from underground storage tanks (USTs) containing diesel fuel and gasoline are a serious and increasingly prevalent problem in Puerto Rico. Remediation of groundwater impacted by these releases utilizing common methodologies can be quite costly and require long periods of time to implement. Oxygen is often the limiting factor retarding optimal ...


    By REGENESIS

  • Case study - GRO in soil at gasoline UST site

    These case studies show the performance using Sitelab’s UVF-3100 analyzer testing gasoline range organic hydrocarbons.  This includes benzene, xylene, BTEX and other volatile petroleum compounds in the GRO or VPH C6 to C10 hydrocarbon range. When calibrated using Sitelab's GRO calibration kit (CAL-025), the UVF analyzer produces test results that correlate well to laboratory ...


    By Sitelab Corporation

  • Case study - Texas crude oil in soil sites

    Sunset Well Service, Inc. is an environmental contractor located in the Midland/Odessa area of Texas. They use their UVF-3100D analyzer to help excavate and remediate soils contaminated by produced water and crude oil. Laboratories in Texas test TPH using the TX 1005 GC-FID Method. This method is similar to U.S. EPA Method 8015M, but reports the GRO, DRO and ORO fractions separately. Soils from ...


    By Sitelab Corporation

  • Fuel Oil Spill during maintenance in Ohio

    During replacement of oil furnace by an HVAC contractor in Ohio, there was an accidental release of almost 250 gallons of No. 2 heating oil in the basement. The oil seeped below the concrete surface and the smell of heating oil fumes was so strong that the home owner was advised to relocate in a hotel to prevent chemical burn of throat tissues. Environment company in charge of the cleanup removed ...


    By Sarva Bio Remed, LLC

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you