UV254 TOC Articles

  • Control of disinfection by products formation potential by enhanced coagulation

    Abstract Jar-test experiments were conducted to study enhanced coagulation effectiveness in removal of disinfection by products (DBPs) from Zayandehrud River at Isfahan Province-the center part of Iran- in 2004. In this study, the removal of suspended and colloidal particles and natural organic matter (NOM) at various coagulant doses and coagulation pHs was assessed through raw and treated ...

  • Evaluation of fluorescence excitation–emission and LC-OCD as methods of detecting removal of NOM and DBP precursors by enhanced coagulation

    Bench-scale tests were conducted to evaluate enhanced coagulation as a method for removing natural organic matter (NOM) from a surface water to reduce the formation of disinfection by-products (DBPs). Aluminium sulphate (alum) and two polyaluminium chloride (PACl) coagulants were used, as well as alum with pH depression. Using a PACl coagulant alone or alum with pH depression was shown to attain ...


    By IWA Publishing

  • Surface Water Monitoring - Case Study

    Safe operation of a Water Treatment Plant (WTP) requires careful monitoring of the water supply influent to the plant, as a guard for any substances entering the treatment works that could negatively impact treated water quality in the distribution system. One aspect of water quality that has recently garnered more attention from authorities and utilities is Natural Organic Matter (NOM), which ...


    By MANTECH Inc.

  • Water Treatment Optimization - Case Study

    Drinking water treatment in North America has stringent requirements for effluent water quality, with a great amount of attention being drawn to the presence of hazardous disinfection by-products (DBPs) persisting through water distribution systems. The operation of water treatment plants involves addition of various mixing agents to help with coagulation and settling of organics in the raw water ...


    By MANTECH Inc.

  • A comparative treatment of bleaching wastewater by physicochemical processes

    The bleaching effluent discharged from a pulp and paper mill contains chlorinated organic compounds which are toxic to living matter. Physicochemical treatments such as coagulation and different advanced oxidation processes (AOPs) were employed for combined bleaching effluent generated from the first two stages (i.e. chlorination and alkali extraction) (pH = 3.5, chemical oxygen demand (COD) = ...


    By IWA Publishing

  • Real Tech Inc Brochure

    For over a decade, Real Tech has been providing innovative water quality monitoring solutions. We have combined our advanced sensors with our Liquid Ai data analytics services to offer unmatched accuracy, reliability and detection capabilities for a wide array of parameters and compounds including BOD, COD, TOC, DOC, UV254, UVT, TSS, Nitrate, Nitrite, Algae, Permanganate, Chromium, Colour, ...


    By Real Tech Inc.

  • Demonstrating ultra-filtration and reverse osmosis performance using size exclusion chromatography

    Advanced water treatment plants employing ultrafiltration (UF) and reverse osmosis (RO) membrane processes are frequently implemented for the production of high-quality recycled water. It is important that process performance is able to be quantified and assessed to ensure it is fit for purpose. This research utilizes size exclusion chromatography with organic carbon, organic nitrogen and UV254 ...


    By IWA Publishing

  • Effect of enhanced coagulation by KMnO4 on the fouling of ultrafiltration membranes

    Pre-coagulation enhanced by KMnO4 before ultrafiltration (KCUF) was compared with normal pre-coagulation by alum (CUF) in the ultrafiltration of water from the Songhua River, China. The trans-membrane pressure (TMP) with KCUF was much lower than that when alum alone was used. With KCUF a slower increment of TMP occurred, even under conditions of high river water turbidity. The results also showed ...


    By IWA Publishing

  • Guaynabo WTP in Puerto Rico saves thousands with UV254 Monitoring Package - Case Study

    Summary Dealing with fluctuating water sources is not an easy task for plant operators. Seasonal variation, heavy rain fall or accidental contamination events change the raw water quality, requiring immediate attention. This is a familiar scenario for Facility Manager, Nancy Ma. Cáceres Acosta at the Los Filtros Water Treatment Plant in Puerto Rico. She has been producing highquality ...


    By Real Tech Inc.

  • Faster, more accurate test results for water analysis

    The future is bright for a Guelph company whose innovative water-quality monitoring technology is helping industries and municipalities save millions of dollars while better protecting the environment. MANTECH manufactures water analysis systems that provide faster, more accurate test results while using environmentally-friendly methods. Incorporated in 2010, MANTECH has worked with Innovation ...


    By MANTECH Inc.

  • peCOD is the New NOM Monitoring Tool for Measuring Organic Reactivity - Case Study

    Natural organic matter (NOM) is a critical parameter for measuring drinking water quality.  Levels of NOM are associated with taste, odour, colour, chemical treatment dosage, and disinfectant by-product (DBP) formation.  There are several tools accepted by drinking water quality experts which are used to evaluate NOM: total organic carbon (TOC), dissolved organic carbon (DOC), UV254, ...


    By MANTECH Inc.

  • Nanotechnology Provides Alternative Method to Dichromate Based COD Analysis

    Nanotechnologies hold a lot of promise for improving the world and offering revolutionary advancements over traditional technologies that have not changed for decades, including for water quality analysis. Laboratory staff have known for a long time about the potential negative health impacts associated with Chemical Oxygen Demand (COD) testing using the traditional dichromate method, ...


    By Camlab Limited

  • Controlling Treatment Disinfection Byproduct Creation from Natural Organic Materials

    Safe operation of a water treatment plant requires careful monitoring of the water supply for any substances entering the treatment works that could negatively impact treated water quality. One aspect of water quality that has recently garnered more attention from authorities and utilities is natural organic matter (NOM). This is a group of carbon-based compounds found in natural water systems ...


    By MANTECH Inc.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you