venturi scrubber Articles

  • Particulate Venturi Scrubber System

    A precious metal refiner required the most advanced particulate scrubber to replace wet ESP for submicron particulate collection. Due to the very high gold prices, economic reasons were the driving force toward maximum removal efficiency. Macrotek was selected to design and install their ultra high efficiency flooded disc MVA scrubber. In addition to the high removal efficiency for submicron ...


    By Macrotek Inc.

  • Monroe Scrubbing System provides halide recovery at a major glass products plant

    Challenge A glass manufacturing plant was having trouble cleaning the emitted gases, particulate, and odors that resulted from its manufacturing process. Metallic Halides such as SnCl4 and TiCl4 were being applied to hot glass to impart special properties. The halide and oxide emissions were hazardous, extremely pungent, irritating in odor, and very difficult to scrub. Solution Monroe designed ...

  • Particulate removal - Case Study

    Application QAFCO (the Qatar Fertiliser Company) operates the world's largest ammonia and urea production site at Mesaieed City, Qatar. The QAFCO 5 expansion project is a $3.2 billion investment to expand capacity to help meet the increased demand from agriculture. It is scheduled to come on stream in 2011. Each of the QAFCO plants uses highly explosive high-pressure natural gas from offshore as ...

  • Food Processing: Venturi Scrubber and Separator Cuts Steam Costs Case Study

    New Solutions to Plant Problems:Soybean extraction at Land 0 ‘ Lakes, Inc., Sheldon, IA, is an energy- intensive operation. Beans must be cleaned, properly dried, tempered, cleaned a second time, fragmented, and heat-conditioned to increase smface area and distort cell walls. On the extraction side of the process, soybean flakes are extracted by repeated countercurrent percolation of hexane ...


    By CR Clean Air Group, LLC

  • Monroe scrubber solves pollution and odor problems from a glass resin reactor at a synthetic fiber manufacturing plant

    Monroe scrubber solves pollution and odor problems from a glass resin reactor at a synthetic fiber manufacturing plant Challenge The plant was emitting about 6.0 lbs/hr of toxic fumes from their resin reactor at a temperature of 200oF. The emitted gases to be cleaned were from hazardous, gaseous pollutants such as phenol and formaldehyde, as well as dust particulate. The collection efficiency ...

  • Medical Waste - Egypt & Middle East - Case Study

    Location: Various, Egypt Client: Egyptian Military Armament Waste Type: Pharmaceutical Waste Incinerator(s) Supplied: 26 x i8M-60 Venturi inc. Liquid Feeder Pharmaceutical Waste Programme The geographical size of the country and the remote locations of their field hospitals meant the Egyptian Armament Authority had to deploy a dedicated medical waste incinerator into each region to ...


    By Inciner8 Limited

  • Medical Waste Incinerators - Pakistan - Case Study

    Location: Bohan, Pakistan Clients: Pakistan Government Waste Type: Medical & hazardous waste Solution Supplied: i8M-120 with Venturi Scrubber Medical Waste is a growing challenge to countries around the world. Until recently there were few options available without spending millions of dollars to safely destroy medical waste. There is a better way, and over the last 12 months in Baluchistan ...


    By Inciner8 Limited

  • Pharmaceutical: HCI Fumes Eliminated at Two Plants Case Study

    Little Maintenance Needed On Jet-Venturi Scrubbers; New Solutions Of Plant Problems: Two plants -Tenneco Chemicals, Reading, Pennsylvania and Hoffmann-La Roche, Nutley, New Jersey – are preventing the escape of HCl fumes from their plants by the use of jetventuri wet scrubbers and separators. Fiberglass-reinforced polyester construction of scrubber units is major factor that has allowed the ...


    By CR Clean Air Group, LLC

  • A breath of fresh air - Wet scrubbing eliminates odors associated with processing discarded liquid from cheese manufacturing.

    When International Ingredient Corp.’s drying plant in Monroe,WI, opened in 1994, it was the first plant designed specifically for large-scale drum drying of dairy products for the feed industry.At that time, its only neighbor was a cheese producer. International Ingredient used a land spread technique to process the discarded liquids resulting from its neighbor’s cheese manufacturing process. ...


    By Bionomic Industries Inc.

  • Installation and Opening of Medical Waste Facility

    A delegation of provincial government ministers was present during the opening of a medical waste incinerator facility in Baluchistan Pakistan. It will be used to safely dispose of between 100-15okg per hour of medical grade waste produced by the regions’ hospitals. The model supplied was the i8M-120 medical inicinerator which has recently been re-designed and now features an ...


    By Inciner8 Limited

  • Installation and Opening of Medical Waste Facility

    A delegation of provincial government ministers was present during the opening of a medical waste incinerator facility in Baluchistan Pakistan. It will be used to safely dispose of between 100-15okg per hour of medical grade waste produced by the regions’ hospitals. The model supplied was the i8M-120 medical inicinerator which has recently been re-designed and now features an integrated ...


    By Inciner8 Limited

  • A breath of fresh air - Wet scrubbing eliminates odors associated with processing discarded liquid from cheese manufacturing

    When International Ingredient Corp.’s drying plant in Monroe, WI, opened in 1994, it was the first plant designed specifically for large-scale drum drying of dairy products for the feed industry. At that time, its only neighbor was a cheese producer. International Ingredient used a land spread technique to process the discarded liquids resulting from its neighbor’s cheese ...


    By Bionomic Industries Inc.

  • Chemical Industry: Wet Scrubbing HCL & SiCl4 Fumes Case Study

    This two-stage scrubbing system utilizes a jet venturi scrubber in conjunction with a counter current packed tower including entrainment mist eliminator. It was designed to eliminate the HCl (hydrochloric acid) fumes generated when SiC14 (silicon tetrachloride) comes in contact with moisture during processing operations at a zirconium processing tank farm, and also the remaining small amount of ...


    By CR Clean Air Group, LLC

  • Scrubber Removes Grease and Particulates from Air Exhaust

    Operating Issue A food-industry leader in Alabama operates several pork-sausage cookers that exhaust over 4,000 ACFM of moisture and pork grease. The operator installed Electrostatic Precipitators (ESPs) to treat the exhaust but these systems performed poorly and generated high maintenance and operating costs. Additionally, these systems were antiquated and required significant capital ...


    By Pollution Systems

  • Activated carbon regeneration furnance waste heat recovery system - Case study

    A UK-based edible oils processing plant use activated carbon in order to clean up various contaminants contained within the oils for product quality reasons. The spent carbon is regenerated on-site in a gas fired rotary hearth furnace and the hot exhaust gases (700°C) from the furnace are a valuable high grade source of waste heat. Waste heat recovery system installed for a UK based edible ...


    By ThermTech Limited

  • Integrated maximum efficiency air pollution control system

    A major uranium refiner required an air pollution control system to control emissions from their hazardous incinerator. The presence of radioactive material demanded that outlet emissions approach non-detectable levels. Macrotek was contracted to design and supply the system. Advanced, cutting edge technology was used to design a system with the lowest possible emissions, which has been ...


    By Macrotek Inc.

  • Thirty Years of Satisfactory Fluid Bed Sludge Incineration - The Northwest Bergen County Utilities Authority Experience

    ABSTRACT Fluid bed incineration has been used as a sludge disposal method at the Northwest Bergen County Utilities Authority since 1969 when the first incineration unit was installed. In 2000, the third generation plant became operational. Over this period, environmental regulations have changed, as have the State mandated air pollution control devices. Since the State mandated a wet ...

  • To MACT and Beyond case study

    In the 1970s, FMC Corp., a chemical manufacturer headquartered in Philadelphia, began operating a high-efficiency thermal destruction facility to dispose of hazardous liquid wastes at its Baltimore pesticide manufacturing plant. The facility used a thermal oxidizer with a rapid quencher and packed tower scrubber to remove air pollution emissions. The system was upgraded in the early ’80s ...


    By Bionomic Industries Inc.

  • RA2205 (UNS S31803/32205) Venturi Scrubber Unit for a Direct Reduced Iron (DRI) Facility fabricated by Douglas Brothers case study

    Kvaerner Metals recently specified 2205 duplex stainless steel for several pieces of equipment to be used in a direct reduced iron (DRI) production facility. RA 2205 was used for two venturi scrubber units as well as two separation units. The design of the equipment was performed by Bionomic Industries of Mahwah, NJ. Douglas Brothers Inc. of Portland, ME was selected to fabricate the units. The ...


    By Bionomic Industries Inc.

  • New fertilizer industry gas cleaning technology achieves lower required emission levels

    All fertilizer plants produce dust and gases, such as ammonia (NH3) and acid fumes, which must be removed at very high efficiencies before venting to atmosphere. Familiar examples are granulation and prilling of nitrogenous products such as Urea which is the most widely used fertilizer in the world(1). Phosphatic fertilizer production produces dust and Fluorine compounds. Typical air treatment ...


    By Kimre Inc.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you