venturi scrubber Articles

  • Pharmaceutical: HCI Fumes Eliminated at Two Plants Case Study

    Little Maintenance Needed On Jet-Venturi Scrubbers; New Solutions Of Plant Problems: Two plants -Tenneco Chemicals, Reading, Pennsylvania and Hoffmann-La Roche, Nutley, New Jersey – are preventing the escape of HCl fumes from their plants by the use of jetventuri wet scrubbers and separators. Fiberglass-reinforced polyester construction of scrubber units is major factor that ...


    By CR Clean Air Group, LLC

  • Case History - Sale of By-product HCl Covers Cost of Emission-Control System

    Problem: Some of the specialty chemical processes at a major chemical manufacturer's plant result in considerable HCl loading in the off-gas. The HCl must be removed before the off-gas can be discharged to the atmosphere. Production of saleable by-product HCl solution was an important goal when looking for a high-efficiency HCl removal system. The company wanted to achieve a very low ...


  • Sale of by-Product HCl Covers Cost of Emission Control System

    Problem: Some of the specialty chemical processes at a major chemical manufacturer's plant result in considerable HCl loading in the off-gas. The HCl must be removed before the off-gas can be discharged to the atmosphere. Production of saleable by-product HCl solution was an important goal when looking for a high-efficiency HCl removal system. The company wanted to achieve a very low ...


  • Chemical Industry: Wet Scrubbing HCL & SiCl4 Fumes Case Study

    This two-stage scrubbing system utilizes a jet venturi scrubber in conjunction with a counter current packed tower including entrainment mist eliminator. It was designed to eliminate the HCl (hydrochloric acid) fumes generated when SiC14 (silicon tetrachloride) comes in contact with moisture during processing operations at a zirconium processing tank farm, and also the remaining small amount of ...


    By CR Clean Air Group, LLC

  • Monroe Scrubbing System provides halide recovery at a major glass products plant

    Challenge A glass manufacturing plant was having trouble cleaning the emitted gases, particulate, and odors that resulted from its manufacturing process. Metallic Halides such as SnCl4 and TiCl4 were being applied to hot glass to impart special properties. The halide and oxide emissions were hazardous, extremely pungent, irritating in odor, and very difficult to scrub. ...

  • A breath of fresh air - Wet scrubbing eliminates odors associated with processing discarded liquid from cheese manufacturing

    When International Ingredient Corp.’s drying plant in Monroe, WI, opened in 1994, it was the first plant designed specifically for large-scale drum drying of dairy products for the feed industry. At that time, its only neighbor was a cheese producer. International Ingredient used a land spread technique to process the discarded liquids resulting from its neighbor’s cheese ...


    By Bionomic Industries Inc.

  • Chemical Industry: Sale of by-Product HCl Covers Cost of Emission Control System Problem Case Study

    Some of the specialty chemical processes at a major chemical manufacturer’s plant result in considerable HCl loading in the off-gas. The HCl must be removed before the off-gas can be discharged to the atmosphere. Production of saleable by-product HCl solution was an important goal when looking for a high-efficiency HCl removal system. The company wanted to achieve a very low level of ...


    By CR Clean Air Group, LLC

  • Particulate removal - Case Study

    Application QAFCO (the Qatar Fertiliser Company) operates the world's largest ammonia and urea production site at Mesaieed City, Qatar. The QAFCO 5 expansion project is a $3.2 billion investment to expand capacity to help meet the increased demand from agriculture. It is scheduled to come on stream in 2011. Each of the QAFCO plants uses highly explosive high-pressure natural gas from ...

  • A breath of fresh air - Wet scrubbing eliminates odors associated with processing discarded liquid from cheese manufacturing.

    When International Ingredient Corp.’s drying plant in Monroe,WI, opened in 1994, it was the first plant designed specifically for large-scale drum drying of dairy products for the feed industry.At that time, its only neighbor was a cheese producer. International Ingredient used a land spread technique to process the discarded liquids resulting from its neighbor’s cheese manufacturing process. ...


    By Bionomic Industries Inc.

  • To MACT and Beyond case study

    In the 1970s, FMC Corp., a chemical manufacturer headquartered in Philadelphia, began operating a high-efficiency thermal destruction facility to dispose of hazardous liquid wastes at its Baltimore pesticide manufacturing plant. The facility used a thermal oxidizer with a rapid quencher and packed tower scrubber to remove air pollution emissions. The system was upgraded in the early ’80s ...


    By Bionomic Industries Inc.

  • Integrated maximum efficiency air pollution control system

    A major uranium refiner required an air pollution control system to control emissions from their hazardous incinerator. The presence of radioactive material demanded that outlet emissions approach non-detectable levels. Macrotek was contracted to design and supply the system. Advanced, cutting edge technology was used to design a system with the lowest possible emissions, which has been ...


    By Macrotek Inc.

  • Wet Scrubbing HCL & SiCl4 Fumes

    This two-stage scrubbing system utilizes a jet venturi scrubber in conjunction with a counter current packed tower including entrainment mist eliminator. It was designed to eliminate the HC1 (hydrochloric acid) fumes generated when S1C14 (silicon tetrachioride) comes in contact with moisture cluring processing operations at a zirconium processing tank farrn, and also the remaining smail amount of ...


  • Chemical Industry: HCL System Exceeds Current Regulations Emission control meets requirements while recovering by-product for sale Case Study

    Chemron manufactures high-quality specialty chemicals and surfactants for personal care products, industrial, institutional, oil field, mining, coatings, lubricants and water treatment. Some of the operations result in the creation of hydrochloric acid with high variable rates. As expressed by Bill Frost, of Chemron: “Chemron maintains a strong environmental commitment, which views ...


    By CR Clean Air Group, LLC

  • Multiple stage scrubbing and adsorption system for Incinerator exhaust at an industrial waste processing plant

    Challenge Monroe Environmental was called upon to purify a 20,000 CFM exhaust stream that was being discharged from an industrial waste incinerator at 2000° F. The pollutants that needed to be removed were: Fine Ash Particulate HCL Gas Mercury Dioxins The combination of soluble and solid pollutants, coupled with the ...

  • HCL System Exceeds Current Regulations

    Chemron manufactures high-quality specialty chemicals and surfactants for personal care products, industrial, institutional, oil field, mining, coatings, lubricants and water treatment. Some of the operations result in the creation of hydrochloric acid with high variable rates. As expressed by Bill Frost, of Chemron: “Chemronmaintains a strong environmental commitment, which views regulations as ...


  • Air pollution control for the fertilizer industry in the Middle East - Case Study

    Through our subsidiary company, APC Process Engineering, ERG has an impressive track record in the Middle East Fertilizer Production Industry. All our systems come with a performance guarantee backed by more than 30 years of experience successfully treating industrial air pollution around the world. ERG’s systems are used for treating silica, phosphate rock and scale dust, ammonia, hydrogen ...

  • Thirty Years of Satisfactory Fluid Bed Sludge Incineration - The Northwest Bergen County Utilities Authority Experience

    ABSTRACT Fluid bed incineration has been used as a sludge disposal method at the Northwest Bergen County Utilities Authority since 1969 when the first incineration unit was installed. In 2000, the third generation plant became operational. Over this period, environmental regulations have changed, as have the State mandated air pollution control devices. Since the State mandated a wet ...

  • New fertilizer industry gas cleaning technology achieves lower required emission levels

    All fertilizer plants produce dust and gases, such as ammonia (NH3) and acid fumes, which must be removed at very high efficiencies before venting to atmosphere. Familiar examples are granulation and prilling of nitrogenous products such as Urea which is the most widely used fertilizer in the world(1). Phosphatic fertilizer production produces dust and Fluorine compounds. Typical air treatment ...


    By Kimre, Inc.

  • Chemical Industry: Silicon Tetrachloride Fume Problem Solved Ccase Study

    A two-stage Jet-Venturi scrubber/packed tower system solved a number of pollution problems for an Albany, Oregon, company. The Zirconium Extraction Div. of Teledyne Wah Chang produces highquality reactor-grade zirconium and hafnium ozide using a chemical separation process. The zirconium and the hafnium are chlorinated and then formed into pure metals for the nuclear and chemical process ...


    By CR Clean Air Group, LLC

  • A cure for Environmental Emissions case study

    Disposing of nearly 1 million pounds of medical waste a month is no easy task. The wet electrostatic precipitator, installed at Rochester, MN-based Mayo Clinic, seems to be just what the doctor ordered. While the medical waste incinerator at Mayo Clinic in Rochester, MN, consistently met state and federal emission requirements, facility leadership recognized that installing a wet electrostatic ...


    By Bionomic Industries Inc.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you