voc detector Articles

  • Subminiature Photoionization VOC Sensor

    Untitled Document 1. Objective Monitoring of Volatile Organic Compounds (VOCs) is required for a number of gas analysis applications, such as: ...


    By MOCON, Inc. - Baseline

  • Stack gas VOC monitoring

    POLLUTION S.r.l. manufactures POLARIS FID analyzer, a cutting-edge technology for the measurement of total hydrocarbons in ambient air and stack emission monitoring in accordance with EN 13526 and EN 12619. This analyser is based on Flame Ionization Detection (FID), a reference method technique to measure total hydrocarbons (THC, VOC, TOC). Polaris FID is a very handy instrument because it allows ...


    By Pollution Srl

  • airmoTWA: New Expert System for GC-FID/MS

    Chromatotec has developed the first TRAP-GC-FID/MS designed for continuous monitoring of Volatile Organic Compounds (VOCs), inorganic molecules and permanent gases. In addition to the mass spectrometer (MS), this system encompasses the same trap, thermo desorption and separation technologies as airmoVOC analyzers (current mCERTS approved GCs analyzers). For VOCs analysis, the Flame Ionization ...


    By Chromatotec Group

  • Building on a legacy of PID development

    Summary From the 1970s to the present day, photo-ionisation detectors (PIDs) have been at the front line of efforts to detect volatile organic compounds. As industrial hygiene has become ever more important and exposure limits for VOCs have reduced, PID technology has continued to develop, providing reliable detection under challenging environmental conditions at concentrations right down to ...


    By Ion Science

  • Air emissions from the automobile manufacturing industry a bio-oxidation pilot study of paint emissions control

    Bio•Reaction Industries (BRI) was contacted by Toyota to assess the abatement potential of an engineered bio-oxidation system (biofilter). The proposed intent of the pilot was to evaluate the effectiveness of biofiltration as available alternative to traditional VOC removal technology on an existing 3 stage wheel paint booth. A pilot unit consisting of a biotrickling filter and a separate ...


  • Air Emissions from the automobile manufacturing industry: a bio-oxidation pilot study of paint emissions control

    Bio•Reaction Industries (BRI) was contacted by Toyota to assess the abatement potential of an engineered bio-oxidation system (biofilter). The proposed intent of the pilot was to evaluate the effectiveness of biofiltration as available alternative to traditional VOC removal technology on an existing 3 stage wheel paint booth. A pilot unit consisting of a biotrickling filter and a separate ...


  • Are your field soil screening procedures providing you with practical and accurate information?

    Untitled Document Environmental consulting activities frequently require that on-the-spot decisions be made in the field concerning the ...


    By Enviro-Equipment, Inc.

  • Natural Gas: Complete Analytical Solution

    Chromatotec® has developed in its Research & Development laboratories, a new instrument for hydrocarbon (C1-C6+) measurements and calorific values as well as WOBBE index computation. This analyzer is based on chromatography principle using a Thermal Conductivity Detector (TCD). The sample will be separated into the column and quantified by the detector. A difference of thermal ...


    By Chromatotec Group

  • Determination of TOC in stack through the innovative FID analyser easy to carry - Case Study

    PROBLEM: The industrial chimney's emissions of Volatile Organic Compounds (VOCs) are becoming issues of global importance and to have an accurate knowledge about how to test VOC turns into a strategic issue. VOC emissions are quantified and monitored according to standard EN 12619, using FID analyzer which uses hydrogen and other reference gases in ...


    By Pollution Srl

  • The Portable FID for Stack Emissions: lightweight, compact, ergonomic, safe

    POLLUTION S.r.l. manufactures POLARIS FID analyser, a cutting-edge technology for the measurement of total hydrocarbons in ambient air and stack emission monitoring in accordance with EN 13526 and EN 12619. This analyser is based on Flame Ionization Detection (FID), a reference method technique to measure total hydrocarbons (THC, VOC, TOC). Polaris FID is a very handy instrument because it allows ...


    By Pollution Srl

  • Case study - Paint mixing

    Overview A company involved in the automotive aftermarket had a paint batch mixing and filling operation that used primers and fillers. They were faced with installing air pollution control equipment to handle the volatile organic compounds (VOCs) emitted by the solvents used in their processes. An independent consultant had determined that total exhaust volume from the facility was ...

  • Innovations in Bench Testing of Waste waters

    Wastewater management in developing countries throughout the world is in a state of crisis. It is estimated that 2.6 billion people worldwide live without adequate sanitation. Resources are scarce, previous management systems have failed, and traditional techniques and solutions are not immediate enough, too expensive, or simply inefficient. Discussion with regards to OI Analytics Instrumentation ...


  • Case study - Catalytic oxidizer catalyst replacement

    Overview A New Jersey pharmaceutical company purchased a thermal incinerator to treat the heptane and hexane exhaust from their capsule wash system. The thermal incinerator"s "tubular" design was modified with a catalyst bed in order to reduce the system"s operational costs. Unfortunately, when operating in the catalytic mode, the oxidizer failed to provide the required ...

  • Full-scale SVE system operates in tandem with groundwater treatment

    Since 1993, SVE has been implemented using two designs at the TP Industrial, Inc. (TPI) site in Gardena, CA, to treat soil contaminated with chlorinated solvents. The SVE system was modified in 1997 to improve emissions control efficiency by using carbon adsorption units that treat effluent from an air-stripping system for treating site ground water. By the end of 2007, SVE had removed a ...

  • The Pitfalls of Process TOC analysis and how to avoid them case study

    Since the introduction of Total Organic Carbon (TOC) Analyzers by Dow, Union Carbide and Automated Environmental Systems in thel960,s,l-5\ they have proven to be an invaluable tool in the environmental and process monitoring fields. While technologies have advanced since then, certain performance characteristics required for true process control have been notably absent. The purpose of this paper ...


    By TOC Systems, Inc.

  • TVOC measurement for LEED/green building evaluation

    Total Volatile Organic Compounds (TVOC) may be evaluated when building designers/managers are pursuing the Leadership in Energy and Environmental Design Green Building Rating System for New Construction (LEED-NC) EQ Credit 3.2. The latest LEED-NC guidance document specifies that the maximum allowed concentration of TVOC measured in a building (post construction, pre-occupancy) is 500 µg/m3; the ...


  • PID in industrial hygiene

    Industrial (or occupational) hygiene places the emphasis on prevention of ill health from work, through recognising, evaluating and controlling the risks. For anyone working with hazardous compounds, these chemicals represent a significant potential source of risk. Modern PID instruments provide reliable detection of over 200 of the most dangerous chemicals, helping to ensure effective industrial ...


    By Ion Science

  • Triad expedites brownfields redevelopment in Fairbanks

    The Fairbanks North Star Borough (FNSB) used Triad in 2006-2007 to assess environmental conditions at a municipal property along the Chena River in Fairbanks, AK. FNSB accelerated the site investigation as part of a brownfields assessment grant received from the U.S. EPA in 2005. Low-level contamination had been identified onsite in past investigations, but its extent and impact on future ...

  • Choosing the correct PID lamp

    The two most common lamps used in PhotoIonization Detectors (PIDs) are 10.6 eV and 11.7 eV lamps. The 11.7 eV lamp measures the broadest range of compounds while the 10.6 eV lamp is more selective. To allow higher energy light to pass through, 11.7 lamps are manufactured with a cylindrical window (the flat surface at the top of the lamp) that deteriorates quickly – even when not in use. ...

  • EPA and DPR Compliant Letter

    Department of Pesticide Regulation Mary-Ann Warmerdam Director Arnold Schwarzenegger Governor 1001 I Street · P.O. Box 4015 · Sacramento, California 95812-4015 · www.cdpr.ca.gov A Department of the California Environmental Protection Agency June 25, 2008 ENF 08-17 TO: County Agricultural Commissioners SUBJECT: ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you