volatil hydrocarbons analyzer Articles

  • System Description for Monitoring Volatile Hydrocarbons

    To help build a comprehensive Industrial Hygiene program, Buck Scientific introduces the IH910 vapor monitoring system utilizing our model 910 gas chromatograph and IH300 air sampling train. Designed to analyze hydrocarbons in air, such as degreasing solvents and paint vapors emitted during plant operations, the IH910 penetrates the 1mg/m3 detection barrier erected by other field portable gas ...


    By Buck Scientific Inc

  • Two Detector Solution to Analyzing Sulfur

    Sulfur compounds are reactive, corrosive to pipes, and destructive to catalysts in petroleum refineries. Sulfur emission are strictly regulated globally. When released into the atmosphere sulfur dioxide converts to sulfuric acid resulting in adverse effects on human health and the environment. Sulfur detection is found useful in many other industries; therefore, detection of sulfur compounds in ...


    By Restek Corporation

  • Volatile organic compounds emitted from hardwood drying as a function of processing parameters

    During the drying of wood, volatile organic compounds are emitted. These emissions contribute, in the presence of nitrogen oxides and sunlight, to the formation of ground level ozone and other harmful photo-oxidants. Emissions of volatile organic compounds from the drying of birch sawdust in a spouted bed were analyzed with a flame ionization detector and with a gas chromatograph-mass ...

  • Detection of semi-volatile organic compounds (SVOCs) in surface water, soil, and groundwater in a chemical industrial park in Eastern China

    China is suffering from serious water and soil pollution, especially in the North China Plain. This work investigated semi-volatile organic compounds (SVOCs) in surface water, groundwater and soil within a chemical industrial park in Eastern China, for which the volatile organic compound (VOC) results have been previously reported. A total of 20 samples were collected from the field, and ...


    By IWA Publishing

  • Analysis of trace hydrocarbon impurities in 1,3-Butadiene using optimized RT-Alumina BOND/MAPD plot columns

    Abstract Identifying and quantifying trace impurities in 1,3-butadiene is critical in producing high quality synthetic rubber products. Standard analytical methods employ alumina PLOT columns which yield good resolution for low molecular weight hydrocarbons, but suffer from irreproducibility and poor sensitivity for polar hydrocarbons. In this study, Rt-Alumina BOND/MAPD PLOT columns were ...


    By Restek Corporation

  • Analyzing sulfur in soil and sediment with handheld XRF

    Background Sulfur creates more than nasty odors. Exposure to low levels (0-10ppm) of hydrogen sulfide (H2S) causes irritation of eyes, nose, and throat; higher levels can cause headaches, dizziness, nausea and vomiting, coughing, and breathing difficulty. H2S and numerous other odor-causing compounds are generated as a result of organic material decomposition. In the case of the Muddy River in ...

  • Texas refinery identifes the source of boiler contamination and restores production using on-line steam condensate analyzer

    Background A major refinery in Texas, USA, recently experienced steam condensate contamination and major fouling of a boiler resulting in damage that led to an unplanned shutdown. The financial impact of the damaged boiler, unscheduled maintenance and loss of production drove a review of current condensate monitoring techniques. The review panel concluded that current methods of ...


    By GE Analytical Instruments

  • Case study - GRO in soil at gasoline UST site

    These case studies show the performance using Sitelab’s UVF-3100 analyzer testing gasoline range organic hydrocarbons.  This includes benzene, xylene, BTEX and other volatile petroleum compounds in the GRO or VPH C6 to C10 hydrocarbon range. When calibrated using Sitelab's GRO calibration kit (CAL-025), the UVF analyzer produces test results that correlate well to laboratory ...


    By Sitelab Corporation

  • Solvent choices for infrared testing of oil and grease in water

    Water is a very strong absorber in the mi d infrared (I R) regio n where o il is measured. We see the effect of infrared absorbance when a cold bucket of water left in the sun is quite warm by afternoon due to the absorption of infrared energy as heat. When measuring part per million (ppm) oil levels with mid IR, the water absorbs so much of the infrared energy that the signal becomes saturated ...


    By Spectro Scientific

  • Will your oil in water analysis method match the regulatory method?

    Anyone involved in field analysis of oil in water will continually get the question “Does your equipment match the regulatory method?” While the amount of oil in water is highly regulated -- it can also be a challenging measurement. It is complicated by the fact that oil comes in many forms and the measurement is defined by the particular regulatory method. When EPA 1664 is the ...


    By Spectro Scientific

  • Expert insight: test method basics for oxidizer permit requirements

    Whenever a new oxidizer is installed to control Volatile Organic Compound (VOC) emissions, the question often comes up: What test method should I use to demonstrate that the device meets permit requirements?   Most states allow you the choice of three EPA Test Methods: 18, 25 and 25A. Of these, use of Method 25A is usually the most desirable, for a few reasons. One, Method 25A provides real ...

  • Priority substances in combined sewer overflows: case study of the Paris sewer network

    This study was undertaken to supply data on both priority pollutant (PP) occurrence and concentrations in combined sewer overflows (CSOs). A single rain event was studied on 13 sites within the Paris sewer network. For each sample, a total of 66 substances, including metals, polycyclic aromatic hydrocarbons (PAHs), pesticides, organotins, volatile organic compounds, chlorobenzenes, phthalates and ...


    By IWA Publishing

  • Field trial of a new commercially available diffusive ground-water sampler

    Field trials of a new commercially available diffusive ground-water sampling device were conducted at two industrial properties in the Blue Ridge Province of North Carolina. The test sites have extensive monitoring well networks and more than five years of historical water quality data. Volatile organic compounds (VOCs) including purgeable aromatics (petroleum hydrocarbons) and halogens ...


    By EON Products Inc.

  • A Dynamic Site Investigation: Adaptive Sampling and Analysis Program for Operable Unit 1 at Hanscom Air Force Base, Bedford, Massachusetts

     Abstract In this study, field analytical instrumentation and methods were used to support a risk assessment study at the airfield at Hanscom Air Force Base (HAFB, Bedford, Massachusetts). The site investigation is part of an ongoing effort to determine contaminant risk to ground water from soil. The field tools supported a dynamic workplan/adaptive sampling and analysis demonstration. Over ...

  • Air Monitoring for the Gulf Oil Spill

    Ambient air monitoring is a priority in the ongoing efforts to contain and manage the oil spill from the Deepwater Horizon in the Gulf of Mexico. The following provides information about the kinds of airborne contaminants that are currently being monitored in the Gulf, how they are collected and how they are analyzed. For a given project, a suitable sampling plan – developed by ...


  • Tacoma, Washington - Well 12A superfund site - Case Study

    Combined Remedies for DNAPL Remediation Project Summary TRS Group, Inc. (TRS) teamed with KEMRON and AMEC, under KEMRON's U.S. Army Corps of Engineers (USAGE) Environmental Remediation Services Multiple Award Task Order Contract (MATOC), to perform electrical resistance heating (ERH) for the remediation of volatile organic compounds (VOCs) in the vadose zone ...


    By TRS Group, Inc.

  • Testing the Waters

    Last summer’s wave of tropical storms left the East Coast scrambling to ensure drinking water quality. Water Quality Products editorial intern Raissa Rocha spoke with Marc Hamel of testing equipment manufacturer Horizon Technology Inc. to discuss the impact weather events may have on water quality. Raissa Rocha: What is your experience with ...


    By Horizon Technology, Inc.

  • Advances in flashpoint testing: economic impact

    Flashpoint testing is one of the oldest methods of the ASTM D02 Committee on Petroleum Products and Lubricants, which was formed in 1904. The most prevalent standards are ASTM D56 (Tag Method), D92 (Cleveland Method), and D93 (Pensky-Martens Method). These classical techniques, commonly referred to as open-cup and closedcup methods, share a common principle: A test flame is lowered into the ...

  • Validation of a New Method for Screening Soil and Water for TCE Contamination

    INTRODUCTION ASTM Method D 7203-06, Standard Test Method for Screening Trichloroethylene (TCE)-Contaminated Media Using a Heated Diode Sensor, (ASTM 2006) can be used to screen a sample of soil or water known to contain the halogenated volatile organic compound (HVOC) TCE. The method calls for measuring the TCE concentration in the headspace above the sample using a heated diode sensor ...

  • Case study - Flexographic printer: efficient emissions

    Problem Control of air emissions has become an important issue that flexible packaging converters must consider when changing or upgrading equipment. Robbie Manufacturing of Lenexa, KS, a producer of printed shrink films, bags and pouches for a diverse range of applications, addressed its emissions in 1991 and 1996 by investing in two catalytic oxidizers to control the EPA-regulated air ...