waste incineration filter Articles

  • Minicipal Waste Incinerator Case History

    Low temperature plant operation had resulted in severe baghouse corrosion and constant dust blockages throughout the system. It was decided to raise the operational temperature of the incinerator and change the acid gas scrubbing agent from lime to sodium bicarbonate. However, the existing felt filter media could not cope with the change in acid gas scrubbing agent and “blinded” very rapidly ...


    By W. L. Gore & Associates

  • Case study - Nuclear Waste Incineration (France)

    Nuclear waste incineration trials 1996 Glosfume successfully provided a pilot filter to carry out various trials on nuclear waste incineration. The filter was designed to operate under vacuum and passed all of the stringent requirements of French Nuclear Fuels. Similar filters have subsequently been used on several sites throughout France, contributing to reduced waste disposal costs and ...


    By Glosfume

  • Case study - HMS Ocean Waste Incinerator

    Ship's Waste Incinerator This installation is Glosfume's first filter to be used at sea. Stringent laws prevent ships from dumping waste at sea, all waste has to be returned to its point of origin. The Royal Navy is one of the first to install an incinerator and filter onboard a ship. Extensive testing was carried out before fitting the unit to HMS Ocean; installation involved cutting a ...


    By Glosfume

  • Optimizing Baghouse Performance in Waste-to- Energy Incinerator

    An end user with many years experience, operating3 different Municipal Waste Incineration plants, decided to build a new “state of the art” plant. After fully investigating the performance of different types of filter media, he decided upon GORE-TEX® membrane on GORE-TEX® felt, as he was convinced that is was the “best available ...


    By W. L. Gore & Associates

  • What is Incineration?

    What is incineration? “Everything you ever wanted to know, but never dared to ask!” In its most basic form, it is the destruction of something, especially waste material, by burning. Incineration is a thermo-decomposition process where the components present in the waste stream are ionized into harmless elements at a higher temperature in the presence of oxygen. ...


    By Inciner8 Limited

  • Case study - Municipal Incinerator (Slovenia)

    WID and BREF-compliant EU showcase municipal incinerator in Slovenia During 2008 Glosfume was asked to supply a ceramic filter which could achieve emission levels below WID. Representing the state-of-the-art in high temperature filtration design rated at 70,589 Am3/hr @ 250 °C. The installation complies both Waste Incineration Directive (WID) and BAT Reference note ...


    By Glosfume

  • A STIEFEL project Waste Incineration Plant (KVA) Trimmis case study

    The waste incineration plant (KVA) Trimmis is situated in the eastern part of Switzerland and is connected to the railway network. As it is the only incineration plant in this province, it serves a large area with approximately 131’000 inhabitants. The local authorities waste disposal association named GEVAG is a public body serving 43 convention communities and 97 associated municipalities ...


    By Jakob Stiefel GmbH

  • Rotary Kiln Incineration Plant - Case Study

    The R1200 plant was installed in the early 00’s in Macau. The fully integrated system boasts a burn rate if 1200kg per hour and accepts a variety of different waste streams that include, clinical waste, pharmaceutical waste, liquid waste that includes solvents, waste oil, shredded tyres and well as some livestock as large as horses. The rotary kilns incineration principle is defined by one ...

  • Foundry by products and casting waste

    There are lots of waste elements generated by the casting process, creating a waste stream that requires specific handling in order to minimise the risk of land contamination, both through the handling process and the storage and disposal of raw materials ...


    By Inciner8 Limited

  • Case study - WID-compliant Wessex Incineration (UK)

    This installation was Glosfume's first use of a new process designed to incorporate an innovative 'radiant heating tube' which allows fumes to cool prior to filter without the need for dilution air and/or a heat exchanger. This design has subsequently been successfully utilised on several similar rotary incinerator installations. The plant was the first to comply with strict Waste Incineration ...


    By Glosfume

  • Mayo finds technical fix to reduce incinerator emissions

    While the medical waste incinerator at Mayo Clinic in Rochester, Minn., consistently met state and federal emission requirements, facility leaders wanted to find a way to go beyond these standards. Mayo Clinic’s medical waste incinerator serves Mayo Clinic, Saint Marys Hospital and Rochester Methodist Hospital, which form the largest group medical practice in the world, and processes 2,000 ...


    By Bionomic Industries Inc.

  • Filter technology to meet evolving regulations

    Maguin has developed the Cercat filter for high temperature air pollution control. In this article, David Gambier and Hélène Real outline the technology, as well as installations planned for 2009. Maguin has been present in the waste thermal treatment field since the 1970s. The company’s knowledge has been built through the turnkey supply of thermal treatment units for different kinds of products ...

  • Talking Trash: The world`s waste management problem

    Trash is a pervasive but unnoticed part of our lives. The great irony of waste management is that even the most efficient and well-run waste collection programs remain out of sight, ignored by the public that they serve. Only with failure does the omnipresence of trash really come to light. Today, many nations face a looming waste management crisis, as their landfills reach capacity and continue ...

  • OTM 17: Determination of Metal Concentrations Using Filters and Solid Sorbents in XRF Analyisis case study

    Eli Lilly and Company (Lilly) operates a waste incineration system located at the Tippecanoe Laboratories in Lafayette, Indiana. This incinerator system includes an Xact multi-metals continuous emissions monitoring system (Xact-CEMS, manufactured by Cooper Environmental Services, LLC) for demonstrating attainment with the Hazardous Waste Combustor MACT for semi-volatile metals, low-volatile ...

  • Quit wasting time in wastewater filtration

    Susan takes pride in the work she does each day. After all, without her expertise in the lab, the plants and animals that live in and around her community’s waterways could suffer. ...


    By GE Healthcare Life Sciences

  • National Environment Management Authority (NEMA) compliant medical waste incinerators in Kenya - Case Study

    Providing advanced solutions to treating Medical Waste whilst complying with all government environmental regulations. The correct solution for treating Kenyas' medical waste Ensuring all international emissions guidelines are adhered to is essential for safe destruction of Medical waste. We recently completed the commissioning of two of our Medical Incinerators ...

  • Medical Waste Management Facility Isle of Man – Addfield C1000 - Case Study

    Offsetting environmental and biosecurity issues whilst providing cost benefits by managing waste on the island. In 2006, Addfield-Techtrol installed a 1000kg per hour medical waste treatment plant on the Isle of Man, UK. The plant was integrated into the existing municipal waste site and conceived to manage a wide variety of hazardous waste streams that included clinical waste, ...

  • Separation and recovery of oil from oily waste materials using anaerobic thermal desrotpion unit technology

    RLC Technologies, Inc.’s Anaerobic Thermal Desorption Unit (ATDU) is an exsitu, non-incineration technology designed to separate hydrocarbons from various matrices including oilfield waste, soil, sludge, sand, filter-cake, tank and tanker bottoms, organic-based hazardous waste and contaminated soil in a non-oxidizing atmosphere without destroying the hydrocarbons. This paper briefly ...


    By RLC Technologies, Inc.

  • Waste Management Overview

    Introduction Our Nation has entered an era in which, as a result of changing world conditions, nuclear weapons production is receiving less attention while the public is expressing increasing concern about protecting human health and preserving the quality of our environment. In response to this national concern, the Department of Energy (DOE) has made waste cleanup and environmental restoration ...

  • Dust monitoring with AirSafe - Case Study

    Application A waste incineration plant burns waste. A fi nal product of this incineration process is fi lter dust, which is stored in silos before being evacuated. For the ambient air monitoring of the silos, convey lines and connected rooms, the plant manager looked for a maintenance-free way to detect dust leaks and malfunctions. Optical techniques were not ...


    By ENVEA

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you