waste incinerator Articles

  • Incineration

    Introduction: High temperatures, 870 to 1,200 °C (1,400 to 2,200 °F), are used to volatilize and combust (in the presence of oxygen) halogenated and other refractory organics in hazardous wastes. Often auxiliary fuels are employed to initiate and sustain combustion. The destruction and removal efficiency (DRE) for properly operated incinerators exceeds the 99.99% requirement for hazardous waste ...

  • Turning waste into wattage

    How we are helping to meet the growing demand for waste energy recovery It’s a sign of the times that more and more companies and organisations are now looking at ways to capitalise on the waste material their production process produces rather than having to pay a third part to take it away for them.  One reason of course is the high cost of scrappage.  Another is the ...


    By Todaysure Limited

  • Municipal Incinerator Waste

    The monitoring of metal concentrations in the waste water from municipal incinerators to ensure compliance with the EU Waste Incineration ...

  • Waste Incinerator Project

      Medical Waste Incinerator YD Model is our classic product for market. All series included burning capacity 10kgs per hour, 30kgs per hour,50kgs per hour,100kgs per hour,150kgs per hour,300kgs per hour,500kgs per hour. Up to now, all models sale to all over the world and have good feedback from end-customer. The YD Model medical incinerator have multi-combustion chamber and basic dry ...


  • Atmospheric impact of a municipal wastes incinerator

    This paper presents a case study of an air pollution dispersion model for the atmospheric impact assessment of a new municipal wastes incinerator (MWI). The capacity of the present MWI will increase more than ten times, and a new high-efficiency flue gas treatment system is projected. The environmental impact study has been focused on the long-term aspect of the air pollution (chronic pollution) ...


    By Inderscience Publishers

  • Minicipal Waste Incinerator Case History

    Low temperature plant operation had resulted in severe baghouse corrosion and constant dust blockages throughout the system. It was decided to raise the operational temperature of the incinerator and change the acid gas scrubbing agent from lime to sodium bicarbonate. However, the existing felt filter media could not cope with the change in acid gas scrubbing agent and “blinded” very rapidly ...


    By W. L. Gore & Associates

  • How big is the distributed energy opportunity for water and wastewater utilities?

    Energy costs for water utilities are large, and growing Energy is a significant cost for many water utilities, and costs are growing as more energy-intensive forms of water supply, including desalination, are being used. Energy is typically the second-largest utility budget item in developed countries, after labour. In many developing countries, energy can account for 70% or even more, of ...

  • Waste Incineration Upgrades at the Eastman Chemical Company

    INTRODUCTION Eastman Chemical Company, headquartered n Kingsport, TN, is an international supplier of organc chemicals, fibers anci plastics with annual sales of approximately $46 biNion and approximately 5300 customers worldwide. Tennessee Eastman Division, also located in Kingsport, is the company’s largest manufacturing fadllity The nine hundred acre site contains manutacturing facilities as ...


  • On-Site Incineration Tames Arsenal Waste Mixture

    Toxic wastes from various chemical processing activities at Rocky Mountain Arsenal (RMA) had accumulated in on-site evaporation basins over many years. The highly corrosive wastes, which posed environmental and potential health hazards, were by-products of the U.S. government’s chemical weapons program during World War 11 and its later weapons disposal program, as weIl as sorne pesticide ...


  • Incineration of hazardous wastes from the petroleum industry in Nigeria

    Persistent hazardous wastes are produced in the recovery, processing and upgrading of crude petroleum in Nigeria. However, recent developments in environmental pollution control are drawing increasing attention to the problems of hazardous wastes. The ever-increasing need to control these wastes from the petroleum industry often compels the chemical engineer to specify methods of treatment and ...


    By Inderscience Publishers

  • Optimizing Baghouse Performance in Waste-to- Energy Incinerator

    An end user with many years experience, operating3 different Municipal Waste Incineration plants, decided to build a new “state of the art” plant. After fully investigating the performance of different types of filter media, he decided upon GORE-TEX® membrane on GORE-TEX® felt, as he was convinced that is was the “best available ...


    By W. L. Gore & Associates

  • Hazardous Waste Incineration Slag Optimisation by Additives

     Abstract Rotary kiln incineration combined with the disposal of residual slag on landfills defined by German landfill regulations is the most acceptable treatment for hazardous waste with respect to the environment. The objective of research is to optimize the elution behavior of HWI-slag. Quality-improved slags may be disposed off on cheaper landfill sites still applying to the landfill ...


  • Waste co-incineration in the European Community, is the sky the limit?

    The co-combustion of waste in industrial furnaces -co-incineration- attracts considerable interest in the European Community, because of the combination of perceived business incentives, regulatory developments, and the slate of available technological options. It was found, however, that EU-regulation developed to ensure safe and environmentally acceptable processing of waste represents a clear ...

  • Particulate Control Strategies for Incineration

    Abstract This paper discusses various particulate emission control strategies that can be employed for Municipal Solid Waste (MSW), Municipal Sewage Sludge, and Industrial Waste Incineration facilities. An example will be given of a particulate control installation that successfully cleans off-gases from an incinerator at a large photographic products plant. Data supporting a theoretical ...


  • Case study - Allburn Incinerators

    PROJECT 19 off containerised Allburn 3 Incinerators World Health Organisation—Ethiopia PROJECT DESCRIPTION Top loaded, diesel fired, low capacity incinera-tors, factory -installed within 20’ ISO shipping containers, for the disposal of bagged general/clinical waste from hospital and clinics, animal and industrial waste. To be ...


    By Todaysure Limited

  • Increase in capacity of an incinerator

    In addition to its own and external products, system providers involved in the project business also provide process knowledge and complete projects refined to the last detail. The standard is high. Their own knowledge combined with the supplier’s knowledge leads to a complete solution. From the delivery of the components to their installation, trial operation and commissioning, all the ...


    By sera GmbH

  • Incinerator Plant, Lidköping - Case Study

    SWEDEN: Baling of MSW In Lidköping the incineration plant is connected to the central heating systems of the city. However, incineration plants has a high demand for fuel in the winter season and limited demand in the summertime. Inflow of material, however, comes evenly all year around and this gives a need to store waste during the summer. The solution to this is the ...


    By Flexus Balasystem AB

  • The municipal solid waste incineration sector in Europe: a study of harmonisation and its impact

    This article discusses how Sustainable Development and Quality Management meet a common target. Companies that excel in Best Available Technology (BAT) respond to expanding sets of expectation of the client and of the legislator. The paper analyses the link between governance, lobbying, and the emergence of economic and environmental feasibility of current quality management factors. In ...


    By Inderscience Publishers

  • Optimizing The Operation And Material Selection For Fluorinated Waste Gas Incineration

    A thermal oxidizer system is used by Honeywell Specialty Chemicals to reduce organic and acid gas emissions from their fluoro-products plant. The thermal oxidizer system consists of a multi-gas fired vortex burner mounted on a vertical residence chamber. ...

  • The Operation And Optimization of R.C.R.A. Permitted Liquid Injection Hazardous Waste Incinerators

    BASF Corporation in Hannibal, MO has operated multiple liquid incinerators for more than 20 years, burning various liquid wastes on a campaign basis. The composition of these wastes range from high organic content liquids to aqueous wastes. ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you