water analysis kit Articles

  • United States Coast Guard (USCG) Implements Handheld Technology for Onboard Oil Testing in New Cutters - Case Study

    With a motto of “Always Ready,” the United States Coast Guard (USCG) has 11 missions specified by law including drug and migrant interdiction; ports, waterways and coastal security; fishery patrols; search and rescue; and national defense. The USCG’s newest ships include 22 Fast Response Cutters (FRCs) which recently entered service, and 36 more are currently on order. ...


    By Spectro Scientific

  • Analysis of PCB in water using the Dtech test system

    MATRIX: Water ANALYTE: PCB LIMIT OF DETECTION: Color Card: 100 ppb (as aroclor 1254), DTECHTOR meter: 50 ppb (as aroclor 1254) BACKGROUND: This application describes a field screening method for determining PCB concentrations in water. A 1:2 dilution of the sample in methanol is made to minimize adsorptive losses. A ...


  • Analysis of PCB in water using the envirogard test system

    MATRIX: Water ANALYTE: PCB LIMIT OF DETECTION: Aroclor 1248: 1 ppm Aroclor 1260: 2 ppm Aroclor 1242: 2 ppm Aroclor 1254: 1.1 ppm BACKGROUND: This application describes a field screening method for determining PCB concentrations in water. A chemical reaction is induced that causes a color change ...


  • Arsenic wood field testing kit

    Now available from Industrial Test Systems, Inc. is a quick, easy, field test kit that can confirm the presence of inorganic arsenic in wood. Arsenic Quick™ 481396-W kit is a modification of the US Patented, ETV Verified arsenic test for drinking water. This 10 minute test readily confirms the absence or presence of arsenic in any wood sample, including CCA treated lumber using safe ...

  • A sensitive presence/absence test kit for detection of coliforms in drinking water

    Coliforms are the most widely accepted bacterial indicator of fecal pollution in water. Several commercially available portable kits make it possible to carry out on-site water quality testing, but are usually costly and often require technical expertise to operate. In developing countries like India, presence/absence test kits like the H2S test kits are commonly used for routine ...


    By IWA Publishing

  • Lead in Soil: Comparison of the Cogent Environmental extraction kits and PDV6000plus analysis (ASV) with inductively coupled plasma optical emission spectrometer (ICPOES) Laboratory Extraction and Analysis

    This study contains data generated by Matrix Environmental when using the PDV6000plus to monitor soils for Lead and subsequent analysis of soil samples by an independent reference laboratory by ICPOES to provide comparison ...

  • Waste to Energy Analysis

    The manufacturing of SRF in a single pass is not a new concept. However, with the environmental efficacy of alternative fuel production under seemingly increasing scrutiny, a one-step process is of growing importance, believes Peter Streinik, Head of Business Unit Waste at UNTHA. There can be no disputing that alternative fuel production is being increasingly acknowledged as a valuable part of ...


    By UNTHA Shredding Technology

  • Estimation of atrazine and simazine concentrations with RaPID ASSAY kits

    MATRIX: Water ANALYTES: Simazine and atrazine LIMIT OF DETECTION:.1 ppb (ng/mL) RANGE OF DETECTION: 0.1 to 3 ppb simazine and 0.1 to 5 ppb atrazine MATERIALS: Simazine RaPID Assay Kit, Atrazine RaPID Assay Kit PROCEDURE and ANALYSIS: Evaluate each water sample with both the ...


  • Compost Data Tracking And Analysis

    From tip fee invoice tracking to process control to compost product sampling, information gathering, analysis and reporting are key to successful facility operations.   COMPOSTING is a highly regulated component ...


    By BioCycle Magazine

  • When Consumables Kits are Greater Than the Sum of their Parts

    ProteinWorks and GlycoWorks kits address more than sample prep challenges One of the most challenging parts of an LC-MS workflow happens before analytical chemists even turn to their instrument: Sample preparation. Get it right, and the analytical run performs as expected. Get it wrong, and the assay has any number of problems, from poor sensitivity to poor reproducibility. The ...


    By Waters Corporation

  • Analysis of Trace Elements in Water by EPA Method 200.8 using ICP Mass Spectrometry

    This application note describes the methodology and use of the Shimadzu ICPMS-2030 ICP mass spectrometer for the analysis of trace elements in drinking and fresh waters following the EPA 200.8 method. This method is also used for analysis of wastewater. In-line addition of internal standards to calibration and unknown samples was accomplished using the Shimadzu Internal Standard Addition ...

  • Fast, Sensitive, and Cost-effective ICPE Spectrometry Analysis of Trace Metals in Water by EPA Method 200.7

    Introduction The Shimadzu ICPE-9820 multi-type ICP atomic emission spectrometer is the ideal instrument for running EPA Method 200.7. The ICPE-9820 permits simultaneous analysis of all elements, at all wavelengths, allowing high-throughput analysis with little need for dilution. The large 1-inch CCD detector with over 1 million pixels measures 110,000 wavelengths. Overflow channels ...

  • Analysis of TNT AND RDX on gauze wipes using the ensys test system

    MATRIX: Gauze Wipe ANALYTE: TNT and RDX LIMIT OF DETECTION: TNT: 7 ug/100 cm2, RDX: 8 ug/100 cm2 BACKGROUND: This application describes a field screening method for determining TNT or RDX concentrations on gauze wipes. Acetone is used to extract the TNT or RDX from the gauze wipe and a chemical reaction is induced ...


  • Progenitor Cell & Neural Stem Products Market 2017 Forecast and Analysis

    ReportsnReports.com adds report Strategic Development of Neural Stem & Progenitor Cell Products to its store.Neurogenesis is the process by which neurons are created. This process is most active during pre-natal development when neurogenesis is responsible for populating the growing brain. Neural stem cells (NSCs) are the self-renewing, multipotent cells that differentiate into the main ...


  • Testing for Nitrates in Water, what are the Options?

    Nitrate is a naturally occurring substance in the environment and is commonly found in most water sources, it is usually only a cause for concern in areas where water supplies can be affected by farm runs offs and agriculture, its use as a fertiliser can cause increased levels in water supplies The ...


    By Camlab Limited

  • The DNA Revolution for Water Professionals

    Imagine trying to solve a problem when you are provided just 1% of the total data. This is essentially the case in analyzing water and wastewater microbiomes. Conventional microbiological testing methods such as culture and microscopy can identify only about 1% of microorganisms that are contained in a ...


    By LuminUltra Technologies Ltd.

  • Detection of PAH IN WATER using the ensys test system

    MATRIX: Water ANALYTES: PAH LIMIT OF DETECTION: 15 ppb MATERIALS: Ensys PAH Risc Soil Test Kit. Methanol (ACS Reagent Grade). Deionized water. Equipment: Ensys Field Accessory System. SAMPLE PREPARATION/ANALYSIS: Follow procedures are outlined in the Ensys PAH Risc Test Kit User’s ...


  • Heavy Metals Water Testing Powered by DNA

    Water pollution is a worldwide problem affecting developing and developed countries alike. Heavy metal contaminants are one prevalent type of water pollutant. They are persistent in the environment once d is charged and removal from source waters is necessary to ensure a clean drinking water supply. The problem of heavy metal pollution arises from several sources. Heavy metals such as uranium can ...


    By ANDalyze

  • Detection of PPT levels of atrazine in drinking water

    MATRIX: Drinking Water ANALYTES: Atrazine LIMIT OF DETECTION: 5 ppt RANGE OF DETECTION: 5 to 500 ppt MATERIALS: Atrazine RaPID AssayÒ Kit and Sample Diluent Reagents: atrazine control (preparation described below), methanol and ethylacetate (pesticide grade) and distilled or deionized ...


  • Evaluation of DNA extraction methods and dilution treatment for detection and quantification of Acanthamoeba in water and biofilm by real-time PCR

    Acanthamoeba, human pathogens and natural hosts of pathogenic bacteria, may be accurately detected and quantified by real-time PCR if Acanthamoeba DNA are properly extracted and PCR inhibitors are effectively eliminated. However, the optimization of DNA extraction methods has not been reported for Acanthamoeba. This study compared the effectiveness of two DNA extraction/purification methods ...


    By IWA Publishing