water flow monitoring Articles

  • Determination of Flow Rates in part-filled Applications using the Radar Method

    Introduction The radar measurement method plays an increasingly important role in the water and wastewater field. This is particularly reflected by the "Metering outside of the medium" trend. Flow measurement using radar which enables contactless measurements thus becomes a major focal point. It features a wide range of applications and hence is useful as permanent measurement system for ...


    By NIVUS GmbH

  • Case Report: ESM30 in lake monitoring

    Background Wuhan is the capital city of Hubei province in central China and has 166 lakes that cover 2,217 square km (856 square miles) and approximately 25% of the city.  This surface water coverage is one of the world’s highest.   The Wuhan Environmental Protection Bureau (WHEPB website: http://www.whepb.gov.cn) is responsible for monitoring the surface water ...


    By Oceanalpha Co., Ltd.

  • Reverse Osmosis and Nanofiltration Membrane Filtration Systems: Common Problems and How to Fix Them

    Reverse osmosis (RO) and nanofiltration (NF) are membrane filtration technologies that are designed to remove solute ions and molecules from a pretreated liquid stream. Well-designed RO/NF units are compact and demand relatively little maintenance, making them an attractive alternative to conventional treatment trains. Even despite the merits of today’s efficient RO/NF technologies, it pays ...


    By SAMCO Technologies, Inc.

  • Scottish Water Flow Monitoring Contracts

    Scottish Water commissioned HL in 2007 to deliver two separate flow monitoring contracts to help improve the water companies understanding of the yield and low flow conditions at several water supply catchments across Scotland. One project involved the installation of reservoir level, inflow flow gauges and recording raingauge devices in nine reservoir catchments in South West Scotland. Although ...

  • Monitoring Flow Rate in a Channel to Minimize Water Pollution

    Recently a wastewater management district in Cleveland contacted CAS DataLoggers to supply an automated monitoring solution for their environmental project. In most cities, sanitary sewers and storm sewers were separate, so that storm water was diverted into a nearby lake. However, Cleveland had only one sewer available, so all of the flow went to the ...


    By CAS DATALOGGERS

  • Monitoring of three drinking water treatment plants using flow cytometry

    A 4-month sampling campaign has been conducted for the monitoring of three drinking water treatment plants using flow cytometry and culture-based methods to provide information related to changes in bacterial concentration according to treatments. Flow cytometry is a fast and user-friendly technique enabling bacteria quantification and viability assessment in less than 1 hour. Specific profiles ...


    By IWA Publishing

  • DFM 5.0 doppler flow meter for frac sand slurry flow monitoring

    CanFrac Sands Ltd. of Lloydmister Saskatchewan (Canada) needed a flowmeter that could accurately measure sand slurry flow without being damaged by this highly abrasive product. They selected the Greyline DFM 5.0 Doppler Flow Meter with a clamp-on ultrasonic sensor mounted on the outside of a pipe. CanFrac produce “fracturing sand” used by the oil and gas industry. This special type of ...


    By Greyline Instruments Inc.

  • Implications of observed and simulated ambient flow in monitoring wells

    The authors of this paper present compelling evidence that conventional monitoring wells act as vertical conduits whenever vertical hydraulic gradients are present (i.e., at most sites). Vertical flow within wells due to natural hydraulic gradients not only makes it impossible to accurately define the vertical distribution of dissolved contaminants within the aquifer, but it can transport ...


    By Solinst Canada Ltd.

  • Portable Monitoring Instruments Solve Flow Rate Mystery

    The Glen Walter Sewage Collection System was built to service 1080 customers in 1989. At the time the population was 850 but by 1995 the sewage treatment plant had already reached capacity. Shawn Killoran took over the Operations Manger position in 1999 and, along with the Mayor and Council, he immediately had concerns about the excess flow. The Township started by video taping all of the lines ...


    By Greyline Instruments Inc.

  • Monitor Dredging Slurry Flow from Outside the Pipe

    Dredging Equipment Manufacturers Choose Non-Contacting Greyline Flow Meters The Challenge Thousands of dredges are operated to maintain navigation channels in our rivers, lakes and harbours and to mine sand and gravel for the construction industry. Managing and optimizing production from a dredge requires continuous monitoring of pipeline pressure, vacuum ...


    By Greyline Instruments Inc.

  • Monitoring Hydrocarbons in Bilge Water

    The Situation Various processes onboard ships, such as machinery wash-down, maintenance, and leakage generate oily wastewater. This contaminated water flow collects in the bilge of the ship. Marine diesel, lubricating oils, grease, as well as garbage may be present in bilge water. The bilge water is discharged overboard, with oil and grease concentrations in the discharged water limited ...

  • Monitoring of water node in wroclaw

    Background Wroclaw's water node has complicated structure. The river Odra has 3 main riverbeds and a lot of channels which are located in the centre of town. There are almost 100 hydro buildings which control flow of the water through the city and protect it against theflood. The great flood in 1997 proved that no one has control over it. Communication systems failure caused ...


    By The OTT Hydromet Group

  • Water quality monitoring with hydrolab MS5

    Background The Škocjan caves are a unique natural phenomenon located in south western Slovenia and are preserved as the Škocjan Caves Park under UNESCO protection. One of the most famous network of underground caves in the world, they were formed by the flow of the Reka River as it bored tunnels through the region’s limestone geology. The river first disappears underground just outside the ...


    By The OTT Hydromet Group

  • Unique technology for monitoring piped water

    INTELLITECT WATER has launched a unique, highly innovative drinking water monitoring technology that will revolutionise the delivery of drinking water. The new technology monitors the quality of water in pipeline distribution networks and for the first time provides reliable data to protect the integrity of the water quality, to enhance customer satisfaction and to improve operational efficiency. ...


    By Intellitect Water Ltd

  • Low-Flow (Mininimal Drawndown) Ground-water Sampling

    The Regional Superfund Ground Water Forum is a group of ground-water scientists, representing EPA's Regional Superfund Offices, organized to exchange information related to ground-water remediation at Superfund sites. One of the major concerns of the Forum is the sampling of ground water to support site assessment and remedial performance monitoring objectives. This paper is intended to provide ...


    By GeoPump, Inc.

  • Case study - Water accountability portable monitoring instruments solve flow rate mystery

    The Glen Walter Sewage Collection System was built to service 1080 customers in 1989. At the time the population was 850 but by 1995 the sewage treatment plant had already reached capacity. Shawn Killoran took over the Operations Manger position in 1999 and, along with the Mayor and Council, he immediately had concerns about the excess flow. The Township started by video taping all of the lines ...


    By Greyline Instruments Inc.

  • Performance monitoring & troubleshooting with a new individual condenser tube circulating water flow and fouling (ClA/FF) meter - case study

    Introduction Midwest Generation Joliet Station in Illinois has two coal-fired units, Unit 7 and Unit 8. Roth 550 MW units are located on the Des Plaines River and have been in operation since 1963-1964. The circulating water system is a once-through system comprised of a bar rack, traveling screens, circulating water pumps and reversible condensers. The original condenser tubes on Unit ...


    By Intek, Inc.

  • Online Total Bacteria Monitor compared with ATP and flow cytometry - Case Study

    Alkaline Phosphatase Enzyme Activity Measurement as a Robust on-line Monitoring Assay for Water Quality Assessment. Micro organisms maintain their growth by producing enzymes in order to provide low molecular weight inorganic compounds. These compounds could be taken up into the cells from high molecular weight organic compounds which cannot be directly utilized by bacteria. Microbial ...


    By microLAN B.V.

  • Effective monitoring improves sewage flow management case study

    SmartScan 50 introduces an effective solution for flow measurement of sewage water in one of Poland's municipal waste water treatment plant. The city of Zblewo, Poland provides waste water treatment services to its inhabitants. The plant sought an ultrasonic measurement solution for monitoring the raw sewage flow during the treatment process. The problems When entering the ...

  • Hydraulic modeling and water quality monitoring

    Untitled Document The 2004 IMTech conference held in Baltimore, Maryland, April 18-20, attracted hundreds of water professionals interested in the application of IT solutions in water supply and distribution ...


    By Innovyze

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you