water meter calibration Articles

  • TLC meter “how-to” video: two-point user calibration

    A Solinst TLC Meter measures water level, temperature, and conductivity. To ensure accuracy of readings, the user can easily calibrate the Meter for conductivity, as required. User calibration allows for adjustment of a TLC Meter if the probe has been altered slightly due to mechanical, biological or chemical affects. If a TLC Meter is tested in standard calibration solution, and the readings are ...


    By Solinst Canada Ltd.

  • Calibration and characterization of an improved low-cost water content sensor

    Inexpensive, accurate, and reliable soil moisture measurements are necessary in countless applications from research to hydroponics. Many have dreamed of these types of sensors being so inexpensive that they could be spread over a wide area to monitor water status at numerous locationsin a watershed, greenhouse, or golf course to name a few. However, measurements of this sort are only as valuable ...


    By METER Group, Inc.

  • The Function of an Ultrasonic Flow Meter

    Running a water management operation requires taking a wide range of measurements. In addition to measuring the flow in your system, many systems must measure the water level of their channel, and one of the best tools for accomplishing this goal is an ultrasonic flow meter. ...


    By TRACOM Inc.

  • Does traditional calibration hide errors in your demand analysis?

    Untitled Document A well-calibrated water distribution model can address numerous ...


    By Innovyze

  • What are the key steps in measuring pH? Why do I need to calibrate?

    pH is a useful parameter which is used across all industries for quality control, environmental monitoring, lab work and much more. There are 10 key steps which should be followed to ensure pH measurements using a meter are accurate. pH is a useful parameter which is used across all industries for quality control, environmental monitoring, lab work and much ...


    By Camlab Limited

  • Calibration using 5 flow sensors saves the effort of extensive reconstruction measures

    "Abwasserzweckverband Breisgauer Bucht", a municipal association for sewage treatment in the south of Germany, operates a central wastewater treatment plant for its members (29 communities and cities). The WWTP covers a catchment area of 650km² and its treatment capacity is 600.000 population equivalents. The plant is treating wastewater from 375.000 residents as well as from industry and ...


    By NIVUS GmbH

  • Mexico - HydroMet Calibration Vehicle with WS501 weather station on board - IGS Hydro - Case Study

    The Office of Meteorology and Hydrology in Mexico equipped a vehicle with measurement technology for verification of their Hydro-Met stations. We are proud that they decided to choose our smart WS501 compact weather station (All-in-one) for measurement of the meteorlogical parameters. With the integration of the smart weather sensor WS501-UMB the calibration vehicle can provide accurate data ...

  • InfoWorks aids the introduction of Cambridge’s district meter areas

    Cambridge Water in eastern England has used InfoWorks WS to develop an all-mains model of the city’s distribution system and applied it to the design of district meter areas to help control leakage. Close correlation between model predictions and field testing has given the engineers confidence in implementing the new system, which is being carried out during 2008.  The networkCambridge ...


    By Innovyze

  • VIDEO: Mass Flow Meters for Power Plant Applications

    Generating electricity in a natural gas power plant is a complex process due to the multiple steps involved with the different types of fluids being used and optimized. Dr. John Olin, Founder of Sierra Instruments, explains how thermal mass flow meters, vortex flow meters, and ultrasonic flow meters can improve the flow energy management in power plant ...


    By Sierra Instruments, Inc.

  • Decision support system for the optimal design of district metered areas

    The establishment of district metered areas (DMAs) is widely recognized as one of the most effective techniques for the optimal management of water distribution networks (WDNs). However, its implementation in real cases is a very challenging task that requires decision aiding. In this work, a comprehensive methodology for the optimal design of DMAs is presented and discussed. The proposed ...


    By IWA Publishing

  • Product of the Month – Handy Polaris 2 Portable Dissolved Oxygen Meter with Datalogger

    This month the focus is on the Handy Polaris 2 Portable Dissolved Oxygen Meter with Datalogger. Over the summer months we have seen increased interest in the instrument. Warmer temperatures can affect the chemistry, biological processes and dissolved oxygen levels in water, making the Handy Polaris 2 a popular ...


    By Partech (Electronics) Ltd.

  • Advances in Thermal Dispersion Mass Flow Meters - Part 1 Principle of Operation

    Abstract This paper describes an advanced microprocessor-based thermal dispersion mass flow meter that uses four temperature sensing elements in its flow sensor instead of the traditional two elements and has a dry velocity sensor that uses no potting materials instead of the traditional potted velocity sensor. This unique new mass flow meter automatically manages changes in gas selection, ...


    By Sierra Instruments, Inc.

  • Scottish Water case study

    Scottish Water, 2007 ongoing Improving reservoir yield assessments and compensation flow monitoring Scottish Water commissioned HL in 2007 to deliver two separate flow monitoring contracts to help improve the water companies understanding of the yield and low flow conditions at several water supply catchments across Scotland. One project involved the ...


    By Hydro-Logic Services

  • The First Vortex Flow Meter with Apps Wins Innovation Award!

    Thank you to the readers of industry publication, Flow Control Magazine, who voted for Sierra’s InnovaMass 240i/241i iSeries multivariable and volumetric vortex flow meters in Flow Control’s 2016 Innovation Awards. Sierra was awarded an honorable mention. Sierra’s tradition and spirit of innovation ...


    By Sierra Instruments, Inc.

  • Efficient Waste Water Treatment

    Clean drinking water is an essential need of mankind. Often surface water like rivers or lakes is used as drinking water source. To prevent these resources from pollution the effective treatment of waste water is a must. For example in China 75% of discharged waste water is coming from pulp and paper, textile and dyeing industries. To run a waste water treatment plant in the most efficient way ...


    By J.V. Niebergall

  • Renewing Belgrade’s Water Infrastructure

    After the trauma of the 1990s, new foreign and national investments in Belgrade’s water infrastructure is enabling the city to benefit from the latest advances in water supply technology… Introduction Situated on the banks of the rivers Sava and Danube, the citizens of Belgrade, the capital city of Serbia and Montenegro in the Balkans, have long benefited from ready access to water. ...


    By Innovyze

  • Now Measure All Flow Energy in Your Facility - One Solution - Three Metering Technologies

    Facilities managers at large facilities often have the challenging task of managing all the flow energy in their facility with the mandate from upper management to save money on energy costs. To accomplish this goal, it’s critical to get accurate flow measurement data of the flow energy in your facility such as: natural gas, compressed air, steam, chilled and hot water. ...


    By Sierra Instruments, Inc.

  • Scottish Water Flow Monitoring Contracts

    Scottish Water commissioned HL in 2007 to deliver two separate flow monitoring contracts to help improve the water companies understanding of the yield and low flow conditions at several water supply catchments across Scotland. One project involved the installation of reservoir level, inflow flow gauges and recording raingauge devices in nine reservoir catchments in South West Scotland. Although ...

  • Testing for Nitrates in Water, what are the Options?

    Nitrate is a naturally occurring substance in the environment and is commonly found in most water sources, it is usually only a cause for concern in areas where water supplies can be affected by farm runs offs and agriculture, its use as a fertiliser can cause increased levels in water supplies The ...


    By Camlab Limited

  • Wastewater Plant Relies on Thermal Flow Meter for Co-Gen Power Gas Blending Process

    The Rahway Valley Sewerage Authority (RVSA), which operates a large wastewater treatment plant in New Jersey, embarked on a green co-generation waste-to-energy project to power a portion of its operations. The plant performs primary, secondary, tertiary and sludge treatment processes in serving over 250,000 residential customers and 3000 industrial and commercial customers in a 40-plus square ...


    By Modern Pumping Today