water pump monitoring Articles

  • Monitoring of typical pumps and aerator in a water treatment plant

    The wireless vibration network of Wi-care system consists of the communication between three components; the transmitter, the range extender and the receiver. The transmitter is fixed on the machine and transmits the vibration and the temperature data at the measurement point. The second element of the Wi-care wireless network is the range extender, its function is to transmit vibration and ...


    By Wi-Care

  • Monitoring of typical pumps and aerator in a water treatment plant - Case Study

    Equipment, Context: Surface aerator:Vertical equipment, gearbox associated very high cost for wired solution, aggressive environment, very few visual and periodical inspections. Centrifugal pump: Located underground in concrete basement, busy area, pipes and metal structure all around. Effluent pump: Vertical equipment, ...


    By Wi-Care

  • Effective Groundwater Monitoring Using Dedicated Pumping Tubes

    This article describes a groundwater monitoring procedure that does not require decontamination of pumping equipment, eliminates the chance of cross contamination between wells, and uses a surface pump.  Two surface pumps are described, one for water level depths less than 25 feet and one for water level depths greater than 25 feet. Install Dedicated Pumping Tubes ...


    By RotaPump, Inc

  • Case study - Well monitoring for a water supplier

    The municipality company, in city of Luebek, Germany, provides potable water for approximately 120,000 households, all pumped from more than 30 wells.  These wells have water levels as deep as 160 meters.  The water levels of these groundwater wells must be measured with the highest possible accuracy.  Previously, the pressure probe's analogue output signals (4…20mA) that ...


    By OTT HydroMet

  • Raw water intake monitoring - Case Study

    The Situation Hydrocarbons in municipal water supplies, including fresh water and desalination systems, are commonly limited to less than 1 part per million. Surface water from rivers, lakes, or the sea with marine traffic, nearby pipelines, or regular flooding can be contaminated by hydrocarbons. Freshwater treatment systems can be damaged by hydrocarbons or allow them to pass through ...

  • Water Flow Monitoring Helps Avoid Costly Fines

    Water Distribution Company Refines Pumping System Many water distribution companies use a similar process for Water Flow Monitoring:  Collect water from a well with the help of water pumps, utilize a pond or reservoir to temporarily store the water and maintain a loading center to fill water trucks for transport. The problem is how to pump the maximum allowable volume of water on a ...


    By CAS DataLoggers

  • Water quality monitoring following Hurricanes Katrina and Rita

    Following the passage of Hurricane Katrina, New Orleans was left with 80% of its land area flooded. In some locations, the flood waters were over 30 feet deep. In the heat and stagnation, the waters quickly became heavily polluted. Pump out operations began in early September 2005 to get the city dried out quickly. Lake Pontchartrain was the primary receiving water body. A variety of approaches ...


    By Inderscience Publishers

  • Selecting a pump for sea water reverse osmosis

    Reverse osmosis (RO) desalination has become a significant process used in the purification of water. Selecting the correct pump is a significant step in a well designed and properly operating pumping system. Although the pump is a relatively small part of the overall cost of an RO system, expenses resulting from downtime and inefficiency can quickly diminish the productivity of the RO system and ...


    By Cat Pumps

  • Hand-pumps as reservoirs for microbial contamination of well water

    The retention and release of total coliforms and Escherichia coli was investigated in hand-pumps removed from tubewells tapping a faecally contaminated aquifer in Matlab, Bangladesh, and from a new hand-pump deliberately spiked with E. coli. All hand-pumps were connected to reservoirs of sterile water and flushed. Faecal coliforms were observed in the discharge from all three of ...


    By IWA Publishing

  • Unique Chinese wetland park monitors water 24/7

    Project background The Deyang area in southwest China was struck hard by an earthquake in 2008. Since then, reconstruction has taken place with a tremendous speed and the urban population grew exponentially. Due to this urbanisation, the city’s water supply system can not meet its rapidly growing water demand. Currently, two-thirds of ...


    By Eijkelkamp Soil & Water

  • Water Level Monitoring and Control Solutions for the UK Internal Drainage Boards

    Pulsar Process Measurement have been involved in design, manufacture and supply of non-contacting Ultrasonic Level and Pump Control systems for the Internal Drainage Board industry for many years. Three typical examples of the application of this equipment are installed at North Level IDB Cross Guns Pumping Station. The original Cross Guns Pumping Station was built in 1938 to house three 760mm ...

  • Watson-Marlow OEM pumps help meet rising demand for chlorine monitors

    A specialist manufacturer of water quality measurement and monitoring systems is using peristaltic pump technology from Watson-Marlow Fluid Technology Group for use in chlorine monitoring equipment after similar pumps were found less reliable. With customers that include water, industrial and pharmaceutical companies, Analytical Technology Inc (ATI) designs and manufactures its products in ...

  • Water Corporation

    Introduction the Water Corporation was established under statute as a corporatized entity. The mission of the Water Corporation is to conduct a successful business providing quality water and wastewater services to customers to enhance their lifestyle and to support the future development of the State. Asset Monitoring Services was established within the Corporation to undertake data ...


    By KISTERS AG

  • Algorithmic network monitoring for a modern water utility: a case study in Jerusalem

    We report on the design, deployment, and use of TaKaDu, a real-time algorithmic Water Infrastructure Monitoring solution, with a strong focus on water loss reduction and control. TaKaDu is provided as a commercial service to several customers worldwide. It has been in use at HaGihon, the Jerusalem utility, since mid 2009. Water utilities collect considerable real-time data from their networks, ...


    By IWA Publishing

  • Case study - Superfund site, water pump & treat system

    Anguil Aqua Systems LLC was contracted as part of a team of companies to implement a ground water pump and treat system intended to remove trichloroethylene (TCE) from a local aquifer designated as a Superfund Site by the Environmental Protection Agency (EPA). Though the site is nestled between the buildings and roadways of an existing and operating industrial facility, the overall extent of the ...

  • Pulsar`s Quantum 3 Brings Integrated Flow Monitoring to Pumping Station Management

    Northumbrian Water has installed Pulsar Process Measurement's Quantum 3 Pumping Station Controller which features, apart from a suite of advanced pump control functions based on Pulsar's non-contacting ultrasonic level measurement, the ability to link in up to four Flow Pulse non-invasive flow monitors. Northumbrian Water has used the system to increase station efficiency by identifying ...

  • The Alternative to Pump and Treat

    Sometimes, an important technological advance begins with a small step – back! Such is the case with remediation of hydrocarbons from groundwater utilizing existing recovery and monitoring wells. For the past few years, state government has based decisions on the amount of clean up that they require by the risk posed to the environment. Risk Based Corrective Action, commonly called 'Rebecca' ...


    By Abanaki Corporation

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you