water treatment chemical feed control Articles

  • Chemical feed control using coagulation computer models and a streaming current detector

    This paper describes the use of both the streaming current detector (SCD) and coagulation computer models to provide real-time data for required coagulant feed rates. The method for computer modeling of coagulation and other water treatment processes/operations was originally developed for Lake Michigan Filtration Plant in Grand Rapids, Michigan (MI). Since the initial implementation, a number ...


    By IWA Publishing

  • Integrated process control for recirculating cooling water treatment in the coal chemical industry

    This work focused on the integrated process of the recirculating cooling water (RCW) treatment to achieve approximate zero emission in the coal chemical industry. The benefits of fractional and comprehensive RCW treatment were quantified and qualified by using a water and mass balance approach. Limits of cycle of concentrations and some encountered bottlenecks were used to ascertain set target ...


    By IWA Publishing

  • Seven Ways Your Facility Isn’t Meeting Effluent Regulations and How to Solve Them

    Whether you own, operate, or help manage a municipal or industrial facility that deals with wastewater, it’s important to understand how wastewater treatment can play a significant role in the overall health of your business, especially when it comes to meeting effluent regulations. This is an important part of the wastewater treatment process to consider, as ignoring it could earn your ...


    By SAMCO Technologies, Inc.

  • Looking Beyond Chemical Water Treatment Case Study

    When you think of an environmentally friendly company, a steel processing plant does not typically come to mind. However, Stripco Inc. of Mishawaka, IN, a manufacturer of production-ready, cold-rolled steel coils, is the exception. In August of 1995, Stripco made a wise decision that also proved to be cost-effective and environmentally- friendly when they installed a Superior Environmentalist ...

  • What Is a Boiler Feed Water Treatment System and How Does It Work?

    For industrial companies using a boiler for its facility, some type of boiler feed water treatment system is usually necessary to ensure an efficient process and quality steam generation. The most appropriate boiler feed water treatment system will help the facility avoid costly plant downtime, expensive maintenance fees, and boiler failure as a result of scaling, ...


    By SAMCO Technologies, Inc.

  • Common Boiler Feed Water Treatment Issues and How to Avoid Them

    When treating boiler feed water (the combination of boiler makeup and condensate return water), several issues can arise that cause boiler scaling, corrosion, fouling, and system failure. Below, we break down the most common boiler feed water issues and how to avoid them to help ensure system efficiency and operational safety. While treating boiler feed water is extremely ...


    By SAMCO Technologies, Inc.

  • TB 45: Boiler feed water degassing lowers operations costs and chemical usage

    ShenLan Environment Inc. located in Shanghai China uses Liqui-Cel® Membrane Contactors in their boilerfeed water treatment systems. These systems realize lower operating costs with the added benefit of reducing the chemicals added to the boiler feed water. BackgroundProper treatment of boiler feed water is an important component of a boiler system. As steam is produced, dissolved solids become ...

  • Full Scale Test on Chemical P Removal During a Step Feed BNR Study at John E. Egan Water Reclamation Plant

    ABSTRACTA full scale nutrient removal study was conducted at the 30-MGD John E. Egan Water Reclamation Plant with a single-stage nitrification activated sludge process and sand filtration. One quarter of the plant’s secondary treatment capacity was used in the study. Simultaneous nitrogen removal through a step feed BNR process and phosphorus (P) removal by chemical precipitation with ferric ...

  • Degasification of boiler feed water with Liqui-Cel® membrane contactors

    Proper treatment of boiler feed water is an important part of operating and maintaining a boiler system. As steam is produced, dissolved solids become concentrated and form deposits inside the boiler. This leads to poor heat transfer ...

  • From Waste in Anodising Plant to New Chemical Product in Sewage Treatment Plants

    Aluminium containing caustic soda used as a pickling agent in the pre-treatment of aluminium before anodising and aluminium containing sulphuric acids used as electrolytes for the formation of oxide layers in anodising plants can be utilised in municipal sewage treatment plants to reduce phosphates and improve precipitation. From the anodiser's point of view, these products are spent once they ...


  • City expands water treatment facilities to meet growth

    The City of Coon Rapids, Minnesota recently completed the expansion and upgrade of its East and West Water Treatment facilities. Production at the plants was increased by 66% at the East Plant and 40% at the West Plant to bring the total design capacity to 22.3 million gallons per day. New filters, additional backwash water reclaim capacity, chemical feed systems, and new control systems for ...


    By Filtronics, Incorporated

  • Spiral-Wound Elements for Potable Water Treatment

    Introduction Any new technology must overcome perceptions of the marketplace, which are not accurate. As a technology moves into new areas of application, new misconceptions also arise. Crossflow membrane technology is no exception. The first man-made, pressure-driven 'crossflow' membranes were made in flat sheet form. This membrane had to be configured in a device, and was first made in ...


  • Electronic Water Treatment Reduces Fouling In Reverse Osmosis

    Reverse Osmosis (RO) is used in processes requiring high-quality, purified water, such in semi-conductor processing or biochemical applications and can be used to treat boiler feed water, industrial wastewater or process water. A water purification technique, it reduces the quantity of dissolved solids in solution. RO uses waterline pressure together with energy consuming pressurizing pumps that ...

  • Reclaimed Municipal or Industrial Wastewater for Power Plant Cooling & Boiler Feed Make-Up Water

    For centuries, water was considered a commodity product and used with little or no restriction. In today’s modern society, water is now being considered a precious resource and considerable effort is put into protecting, recycling, and restricting its use freely. State and Federal agencies have put in place guidelines and regulations restricting its use, especially for industrial use. ...

  • Modular treatment system neutralizes process water

    A self-contained pH control and monitoring sys- tem for ready mixed operations yields clean water for recycling or permitted discharge to the environment. Fortrans' Model 5000S uses car- bon dioxide gas to neutralize high-pH process water, offering precise alkalinity monitoring and control of water in pits, settling basins and other containment areas, as it lowers total suspended solids. Designed ...


    By Fortrans, Inc.

  • In Situ Biological Treatment for Ground Water, Surface Water, and Leachate

    The main advantage of in situ treatment is that it allows ground water to be treated without being brought to the surface, resulting in significant cost savings. In situ treatment, however, generally requires longer time periods, and there is less certainty about the uniformity of treatment because of the variability in aquifer characteristics and because the efficacy of the process is more ...

  • Biofilm control strategies in industrial processing waters

    Bacterial biofilms cause a number of serious problems for industrial fluid processing operations. Mechanical blockages, impedance of heat transfer processes and microbially induced corrosion result in billions of dollars of losses each year. In engineered systems, such as cooling water systems, food processing, and other industrial applications possible risk to public health and product spoilage ...


    By MIOX Corporation

  • Automated dosing of dry treatment chemical with flexible conveyor improves accuracy, safety of filtration system

    Oberlin Filter Company is a global leader in high pressure flat-bed, liquid-solid filtration systems for demanding applications such as filtering heavy metals and resins from colloidal suspensions. The company's top-of-the-line DMax™ filtration system, which cleans 'impregnation resin' wastewater, requires a dry chemical delivery system that provides more precise, cleaner, and safer dosing than ...


    By Flexicon Corporation

  • Five Common Problems with Raw Water Treatment and How to Avoid Them

    For industrial companies treating a raw water source for its processes, there are several issues that can surface during treatment that we see on a regular basis. We’ve broken out the five most common problems with raw water treatment and how to avoid them below. Whether you’re designing a new plant or updating existing equipment, avoiding these five common raw water ...


    By SAMCO Technologies, Inc.

  • Common Cooling Tower Water Treatment Problems and How to Solve Them

    For companies using cooling towers to remove heat from an industrial process or for cooling large buildings, there are several issues that can surface during the cooling tower water treatment process that we see on a regular basis. Because these issues occur often, it’s important to know what to look out for in advance, perhaps saving you some time and resources down the line. ...


    By SAMCO Technologies, Inc.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you