water uv treatment Articles

  • Emerging Trends In UV Disinfection For Water Treatment

    Introduction The UV disinfection industry has experienced tremendous growth over the last 20 years.  The development of new UV technologies over this period has been a perfect example of an industry investing to meet market demand – in this case demand for an effective, low cost, and environmentally friendly disinfection technology.  The acceptance of UV disinfection at water plants ...

  • Anglian water choose atg UV for effluent treatment

    Client: Anglian Water   Location: Great Billing, Special Operations Site Description: Effluent Waste Water atg UV Technology, pioneers in the design and engineering of Ultraviolet treatment systems have won supplied Anglian Water with two compact, closed chamber, Ultraviolet disinfection systems for the treatment of effluent waste ...


    By atg UV Technology

  • UV Ballast Water Treatment Close to US Approval

    Shipowners have found it increasingly difficult to comply with ballast water treatment regulations in the US. But there’s good news on the horizon thanks to DESMI’s newest UV-based solution Ultraviolet radiation (UV), which counters microorganisms by rendering them unable to reproduce, is the preferred method for today’s ballast water treatment systems. This robust and reliable ...


    By DESMI A/S

  • Low energy mixing to optimize anaerobic digestion at the Kitchener WWTP

    The existing Kitchener Wastewater Treatment Plant (WWTP) is a conventional secondary treatment facility, with a rated capacity of 122,745 mVd. The plant is comprised of two separate secondary treatment plants (Plant 1 and Plant 2) served by a common headworks facilities and primary clarifier facilities. Plant 1 was constructed in the early 1960s and Plant 2 was constructed in the mid-1970s. Both ...

  • Treatment of winery wastewater by UV-A radiation

    Winery wastewater typically has a pH of 3-4, with COD (chemical oxygen demand) of 800-12800 mg/L, and Biochemical Oxygen Demand (BOD) 1500-6000 mg/L depending on the vintage cycle. To date, there has been no general agreement on the most suitable method for the treatment of winery wastewater. On the other hand, Advanced Oxidation Processes (AOPs) based on various techniques offer a promising ...


    By Inderscience Publishers

  • Self-Cleaning Filtration for Pretreatment of Membrane, UV and Ozone Water Treatment Systems

    Recent field data has shown the effectiveness of automatic self-cleaning filters in removing suspended solids down to less than 3 microns in size without flocculents, pre-coats or granulated media. Pre-treatment of ozone systems is often needed to remove organic solids that would utilize high amounts of ozone during oxidation leaving little for complete disinfection. Selfcleaning screen filters ...

  • Utilizing UV, ozone & AOP technologies for municipal, industrial & waste water treatment

    ESCO International Solutions & Technologies provide a unique portfolio of technical expertise and equipment, specializing in Ozone, UV and Advanced Oxidation Processes (AOP) for water, gas effluent & Odour treatment. Adapting to strict user guidelines and customer focused design means ESCO International systems are reliable and delivers high water purification standards. As conventional ...


    By ESCO International

  • Self-Cleaning Filters for Pretreatment of Membrane and UV Water Treatment Systems

    The removal of suspended solids is necessary to protect membrane systems and prevent the “shadow effect” in ultraviolet (UV) treatment systems. Recent field data has shown the effectiveness of automatic self-cleaning filters in removing suspended solids down to less than 3 microns in size without flocculants, pre-coats or granulated media. Tests have demonstrated the complete removal of particles ...

  • The effect of chlorine and combined chlorine/UV treatment on coliphages in drinking water disinfection

    Chlorine disinfection is a globally used method to ensure the safety of drinking water. However, it has not always been successful against viruses and, therefore, it is important to find new methods to disinfect water. Seventeen different coliphages were isolated from the treated municipal wastewater. These coliphages and MS2 were treated with different dosages of chlorine in drinking water, ...


    By IWA Publishing

  • UV, a bright future for the water industry

    The use of Ultra Violet (UV) light has now become standard practice in most municipal waste water treatment processes.  Effluent is now starting to be recognised as a valuable resource, not a problem that needs to be dumped. Many waste water facilities are being renamed as water reclamation facilities, and whether the waste water is being discharged into a river, being used to irrigate ...


    By atg UV Technology

  • UV Experience for Inactivating Cryptosporidium in Surface Water Plants

    Untitled Document The disinfection of pathogenic microbes in drinking water has been largely successful over the last ...


    By Calgon Carbon Corporation

  • Treating Taste & Odor and Disinfecting Drinking Water with UV

    Cornwall is a city of nearly 60,000 people in Ontario, Canada. It is located on the St. Lawrence River, approximately 1,700 km from the Atlantic Ocean and 2,000 km from Lake Ontario. The city draws its drinking water from the St. Lawrence, a reliable and generally good-quality source. However, in the late summer and early fall, dying algae from algae blooms during the warmest months often ...

  • Water matrix effect on UV photodegradation of perfluorooctanoic acid

    The widespread detection of perfluorinated compounds (PFCs) in the water environment has been a concern for the last several years, while effluents from wastewater treatment facilities are the major sources of these compounds. Even advanced oxidation technologies (AOTs) are not useful for mineralization of the compounds due to their very high stability. Photochemical techniques using particularly ...


    By IWA Publishing

  • New DWI guidelines for UV drinking water disinfection

    atg UV, has seen increasing interest in the application of UV systems for the treatment of drinking water applications since the UK Drinking Water Inspectorate (DWI) released their ‘Guidance on the use of Ultraviolet (UV) Irradiation for the Disinfection of Public Water Supplies' February 2010. With systems treating in excess of 2000 m3/hr daily, Ultraviolet disinfection is no longer an ...


    By atg UV Technology

  • UV Experience for Inactivating Cryptosporidium in Surface Water Plants

    The disinfection of pathogenic microbes in drinking water has been largely successful over the last century due to the use of chlorination. However, research conducted in the 1970's revealed that by-products formed during the chlorination process are potentially carcinogenic and that there is a direct correlation between the concentration of chlorination by-products and the probability of certain ...

  • Case study - Sutton and East Surrey Water - Drinking Water UV Treatment - 5000m3/hr

    atg UV Technology supplied Sutton & East Surrey Water with a US EPA UVDGM Validated solution using 3 x SX-1873-30 UV Systems. The Duty / Assist / Standby plant treats over 5,000 m3/hr of drinking water for a population of over 650,000 people, and has a redundancy of 10,000 m3/hr for future population ...


    By atg UV Technology

  • The Use Of UV For Dechlorination

    For many years chemical disinfection techniques have been used to provide microbiologically pure water for industrial and domestic use. Free chlorine, typically introduced by municipal water treatment plants in gaseous form, has been employed for many decades as a primary oxidising agent for the control of microbiological growth. Free chlorine can also be introduced through the injection of ...

  • Microwave UV - An everlasting lamp?

    Microwave UV Disinfection – An Everlasting Lamp?Many of you working in the water and wastewater industry will have observed the emergence of Ultraviolet technology as a player in the world of disinfection over the past 10-15 years. This article will provide a brief introduction to UV technology and outline a recent advancement in the field: - the generation of UV light using microwave energy ...


    By O2 Environmental Inc.

  • Potential Repair of Escherichia coli DNA following Exposure to UV Radiation from Both Medium- and Low-Pressure UV Sources Used in Drinking Water Treatment

    The increased use of UV radiation as a drinking water treatment technology has instigated studies of the repair potential of microorganisms following treatment. This study challenged the repair potential of an optimally grown nonpathogenic laboratory strain of Escherichia coli after UV radiation from low- and mediumpressure lamps. Samples were irradiated with doses of 5, 8, and 10 mJ/cm2 from a ...

  • Application of a Medium Pressure UV System for the Treatment of N-Nitrosodimethylamine (NDMA)

    N-nitrosodimethylamine (NDMA) was first detected in 1990 as a problem pollutant in drinking water wells at levels as high as 3,000 ppt in Elmira, Ontario, Canada. The waste from a large chemical plant over many years had led to the contamination of the drinking water wells for the community. After extensive evaluation and testing, it was determined that UV photolysis was the most effective ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you