AMETEK MOCON - Baseline

Industries

  • Environmental - Environmental Monitoring

  • Measuring aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring - Environmental - Environmental Monitoring

    Measuring aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring

    The Series 8900 BTEX Analyzer provides direct measurement of Benzene, Toluene, Ethylbenzene, and Xylenes in ambient air. This instrument is utilized in ambient air networks around metropolitan areas and fence-line monitoring at industrial sites. The Series 8900 BTEX Analyzer employs a photoionization detector (PID) as the sensing element. This detector is specific to volatile organic compounds. The Benzene, Toluene, Ethylbenzene, and Xylene`s in the gas sample are physically separated using proprietary GC columns.

  • Oil, Gas & Refineries - Gas

  • Measurement of acetaldehyde, methanol, & benzene in CO2 applications for gas manufacturers & food & beverage industry - Oil, Gas & Refineries - Gas

    Measurement of acetaldehyde, methanol, & benzene in CO2 applications for gas manufacturers & food & beverage industry

    The BevAlert Model 8900 provides direct measurement of Acetaldehyde, Methanol, and Benzene (AMB) in Carbon Dioxide. The instrument is utilized by Specialty Gas Manufacturers and the Food and Beverage Industry to monitor trace impurities in CO2 used in carbonated beverages. The BevAlert Model 8900 employs a photoionization detector (PID). The AMB in the gas sample are physically separated using proprietary GC columns. A dual-column configuration with timed backflush to vent is used to strip off moisture and...

  • Health and Safety - Indoor Air

  • Baseline® 9100 Residual Solvent Analysis — Ethanol, Isopropanol, and Acetone - Health and Safety - Indoor Air

    Baseline® 9100 Residual Solvent Analysis — Ethanol, Isopropanol, and Acetone

    MOCON’s Baseline® Series 9100 Gas Chromatograph equipped with a photoionization detector (PID) provides a quick, cost effective quantitative analysis of IPA and acetone in air at levels in the ppb and sub-ppb range with no preconcentration necessary. Isopropanol and acetone are detected and accurately quantified to sub-ppb levels in under 3 minutes with ethanol producing no interference. The instrument is sensitive to below 5 ppb for both IPA and acetone employing the MOCON Baseline® standard PID or 0.1 ppb...

  • Energy - Bioenergy

  • Measurement of methane, methanol and ethanol for the biomass monitoring for biofuels. - Energy - Bioenergy

    Measurement of methane, methanol and ethanol for the biomass monitoring for biofuels.

    The Series 8900 provides direct measurement of methane, methanol, and ethanol for the biofuel industry. The Series 8900 GC employs a flame ionization detector (FID). The methane, methanol, and ethanol in the gas sample are physically separated using proprietary GC columns. A dual-column configuration with timed backflush to vent is used to strip off moisture and heavier gases. At sample injection, a fixed volume of sample is carried through the pre-cut column. The backflush is timed so that primarily the MME and...

  • Soil and Groundwater - Site Remediation

  • Measurement of naphthalene in ambient air to monitor workplace exposure limits & at remediation & Superfund sites - Soil and Groundwater - Site Remediation

    Measurement of naphthalene in ambient air to monitor workplace exposure limits & at remediation & Superfund sites

    The Series 8900 Naphthalene Analyzer provides direct measurement of Naphthalene in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits and at remediation and Superfund sites. The Series 8900 Naphthalene Analyzer employs a photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection...

  • Monitoring and Testing - Air Monitoring and Testing

  • Measurement of hydrogen sulfide & carbon disulfide in air for continous emission monitoring - Monitoring and Testing - Air Monitoring and Testing

    Measurement of hydrogen sulfide & carbon disulfide in air for continous emission monitoring

    The Series 8900 Hydrogen Sulfide and Carbon Disulfide Analyzer provides direct measurement of H2S and CS2 in ambient air. This instrument is utilized for continuous emission monitoring. The Series 8900 H2S and CS2 Analyzer employs a Photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is...

  • Health and Safety - Workplace Safety

  • Measurement of ethylene oxide for monitoring workplace exposure limits - Health and Safety - Workplace Safety

    Measurement of ethylene oxide for monitoring workplace exposure limits

    The Series 8900 Ethylene Oxide Analyzer combines the selectivity of gas chromatography with the sensitivity of a Photoionization Detector (PID) providing interference free response to Ethylene Oxide (EtO) at levels below 0.05 ppm. This analytical method is referenced in OSHA`s `Occupational Exposure to Ethylene Oxide: Final Standard` 29 CFR Part 1910. The system documents exposure levels including: time-weighted averages (TWA), short-term exposure limits (STEL) and instantaneous alarms. Areas that are typically...

  • Air and Climate - Air Monitoring and Testing

  • Measurement of formaldehyde in ambient air for monitoring workplace exposure limits - Air and Climate - Air Monitoring and Testing

    Measurement of formaldehyde in ambient air for monitoring workplace exposure limits

    The Series 8900 Formaldehyde Analyzer provides direct measurement of Formaldehyde in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits. The Series 8900 Formaldehyde Analyzer employs a flame ionization detector (FID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is...

  • Measurement of methyl bromide in ambient air for monitoring workplace exposure limits in fumigation facilities - Air and Climate - Air Monitoring and Testing

    Measurement of methyl bromide in ambient air for monitoring workplace exposure limits in fumigation facilities

    The Series 8900 Methyl Bromide Monitoring System provides an automated, direct measurement of Methyl Bromide in ambient air. This instrument can meet and exceed the requirements for ambient methyl bromide monitoring. It is utilized in fumigation facilities and industrial plants to detect potential worker exposure to methyl bromide, resulting from mechanical failure, human error or product off gassing. Multipoint sampling options allow the analyzer to monitor multiple sample locations for greater coverage.

  • Measurement of acrylonitrile in ambient air for monitoring workplace exposure limits - Air and Climate - Air Monitoring and Testing

    Measurement of acrylonitrile in ambient air for monitoring workplace exposure limits

    The Series 8900 Acrylonitrile Analyzer provides direct measurement of Acrylonitrile in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits. The Series 8900 Acrylonitrile Analyzer employs a flame ionization detector (FID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is...

  • BTEX in Ambient Air Application using a High-Sensitivity PID - Air and Climate - Air Monitoring and Testing

    BTEX in Ambient Air Application using a High-Sensitivity PID

    The Series 8900 BTEX Analyzer with a high-sensitivity PID provides direct low level measurement of Benzene, Toluene, Ethylbenzene, and Xylene`s in ambient air. This instrument is utilized in ambient air networks around metropolitan areas and fence-line monitoring at industrial sites.

  • Air and Climate - Air Pollution Treatment

  • Air and Climate

  • Measurement of diacetyl in ambient air to monitor workplace exposure limits. - Air and Climate

    Measurement of diacetyl in ambient air to monitor workplace exposure limits.

    The Series 8900 Diacetyl Analyzer provides direct measurement of Diacetyl in ambient air. This instrument is utilized for environmental monitoring and to monitor workplace exposure limits. The Series 8900 Analyzer for Diacetyl employs a photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is...

  • Measurement of methane and non-methane hydrocarbons for environmental air quality. - Air and Climate

    Measurement of methane and non-methane hydrocarbons for environmental air quality.

    The Model 8900 Methane/Non-Methane Analyzer provides direct measurement of Methane and Non-Methane Hydrocarbons. This instrument is utilized in ambient air monitoring networks around metropolitan areas, fence-line monitoring at industrial plants and hazardous waste sites, and in the production of high purity industrial gases. Methane is a naturally occurring gas generated from the decomposition of biological materials and industrial activity. Since Methane is not considered a pollutant it is the Non-Methane...

  • Food and Beverage

  • Total sulfur measurement for sulfur compounds in CO2 for food & beverage industry - Food and Beverage

    Total sulfur measurement for sulfur compounds in CO2 for food & beverage industry

    The BevAlert Model 8900 provides a total sulfur measurement for sulfur compounds in Carbon Dioxide. The measurement includes organic sulfides, Sulfur Dioxide, Carbonyl Sulfide, and Hydrogen Sulfide. The instrument is utilized by Specialty Gas Manufacturers and the Food and Beverage Industry to monitor sulfur compounds in CO2 used in carbonated beverages.

  • Oil, Gas & Refineries

  • Measurement of C1-C5 hydrocarbons for oil & gas exploration. - Oil, Gas & Refineries

    Measurement of C1-C5 hydrocarbons for oil & gas exploration.

    The PetroAlert Model 8900 combines the selectivity of gas chromatography with the sensitivity, broad dynamic range, and hydrocarbon selectivity of a flame ionization detector (FID) providing fast analysis of C1-C5 hydrocarbons required in Mud Logging for Oil & Gas exploration. The PetroAlert Model 8900 uses a dual column configuration with timed backflush to vent which is used to strip off moisture and C6+ hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a...

  • Measurement of C1-C5 with carbon dioxide for oil & gas exploration. - Oil, Gas & Refineries

    Measurement of C1-C5 with carbon dioxide for oil & gas exploration.

    The PetroAlert Model 8900 combines the selectivity of gas chromatography with the sensitivity, broad dynamic range, and hydrocarbon selectivity of a flame ionization detector (FID) providing fast analysis of C1-C5 hydrocarbons and Carbon Dioxide required in Mud Logging for Oil & Gas exploration. The PetroAlert Model 8900 uses a dual column configuration with timed backflush to vent which is used to strip off moisture and C6+ hydrocarbons. A pre-cut column is used in series with the analytical column. At...

  • Chemical & Pharmaceuticals