55 products found

Products

  • Electrolytic

  • AMETEK PI - Model 303B - Moisture Analyzer

    AMETEK PI - Model 303B - Moisture Analyzer

    The Model 303B offers a simple solution to the problem of measuring the moisture content of gas streams. Using an electrolytic (P2O5) sensor, the Model 303B can be used to monitor nearly all gases. It is compact, lightweight, and suitable for both portable use and permanent installation in Class I Div. 2 areas. With the optional carrying bag and lightweight design, the 303B is truly portable.

  • Trace Gas Chromatographs

  • AMETEK PI - Model ta3000 - Gas Analyzers

    AMETEK PI - Model ta3000 - Gas Analyzers

    AMETEK PI - Model ta3000 - Gas AnalyzersTrace Level Gas Monitoring For Bulk Gas, Environmental and Research Laboratory Applications. The Trace Analytical ta3000 series, manufactured by AMETEK Process Instruments, is a family of instruments designed to monitor trace levels of specific impurities in bulk gases, environmental applications and research applications. All ta3000 instruments include a dedicated sample processing system, a single high...

  • AMETEK PI - Model ta5000 - Gas Analyzers

    AMETEK PI - Model ta5000 - Gas Analyzers

    Trace Level Gas Monitoring For Bulk Gas, Environmental and Research Laboratory Applications. The presence of trace impurities in gas supplies and ambient air are of significant concern for bulk gas producers, semiconductor manufacturers, plant environmental safety personnel, and research scientists. The presence of impurities can lower product quality, reduce process yields, skew research results, or indicate a possible environmental hazard.

  • AMETEK PI - Model ta7000 - Gas Purity Monitors

    AMETEK PI - Model ta7000 - Gas Purity Monitors

    The Need: Today's high purity manufacturing processes, especially those in the semiconductor industry, require extremely high purity process gases in order to protect product quality and ensure product yields. As a result, these processes become more complex and vulnerable to disruptions due to the expiration of flow components, component outgassing, and accidental purifier overload. It is crucial to detect contamination before it is spread throughout...

  • AMETEK PI - Model Sigma 4000 - Multipoint Stream Selector

    AMETEK PI - Model Sigma 4000 - Multipoint Stream Selector

    Proper monitoring of the purity of the process gases which feed semiconductor manufacturing equipment and processes requires monitoring at multiple sample points. However, placing individual gas purity analyzers at all these sample points can be very expensive.

  • AMETEK PI - Model MGB1000 - Micro Gas Blender

    AMETEK PI - Model MGB1000 - Micro Gas Blender

    Today's demanding trace impurity detection applications require the utmost in accuracy from the gas purity analyzers monitoring them. To ensure that these high technology analyzers are operating optimally, it is often necessary, or simply desired, to periodically verify their calibration.

  • Gas Chromatographs TCD

  • AMETEK PI - Model 292B - Portable Natural Gas Chromatograph

    AMETEK PI - Model 292B - Portable Natural Gas Chromatograph

    The AMETEK Model 292B natural gas chromatograph is designed as a truly ‘portable’ analyzer. An integrated sample inlet manifold allows for single connections of sample and drive (carrier) gases, allowing for flexible installation either as a stand-alone analyzer, or integrated onto a mobile platform such as a truck or other vehicle. On-site analysis not only eliminates the concerns over accurate sample acquisition and transport, it also...

  • Gas Gravitometers

  • AMETEK PI - Model Ranarex - Portable Gas Gravitometer

    AMETEK PI - Model Ranarex - Portable Gas Gravitometer

    The Need: Plant and process operators need a reliable, simple means of confirming the quality or mixture of process gases. The means used to perform these tests must be reliable, accurate, and very affordable. For many processes and situations, gas quality can be easily inferred through a simple analysis of the gas mixture's specific gravity as opposed to a complex spectral analysis.

  • Infrared

  • AMETEK PI - Model IPS-4 - Integrated Photometric Spectrometer

    AMETEK PI - Model IPS-4 - Integrated Photometric Spectrometer

    AMETEK Process Instruments Model IPS-4 is a huge step forward in capability and reliability for process spectrophotometers. The IPS-4 is capable of measuring up to eight wavelengths in a gas or liquid phase sample. Sample handling and conditioning systems are available as an option that is integrated into the IPS-4's sample cell enclosure.

  • Manual and On-Line Chilled-Mirror Dew Point Analyzers

  • AMETEK PI - Model 241CE II - Hydrocarbon Dew Point Analyzer

    AMETEK PI - Model 241CE II - Hydrocarbon Dew Point Analyzer

    The Model 241CE II Hydrocarbon Dew Point Analyzer is a quality control tool for natural gas processing, distribution and consumption. Detection and measurement of hydrocarbon dewpoint is achieved in a single cell, single cycle operation.

  • Mass Spectrometers

  • Dycor - Benchtop Gas Analyzer

    Dycor - Benchtop Gas Analyzer

    The Dycor Benchtop Mass Spectrometer is a compact versatile gas analysis system for sampling gases over a wide range of pressures, from high vacuum up to and beyond atmospheric pressure. The analyzer and inlet system can be removed from the frame and placed up to 10 feet from the pumping station using the included cable and vacuum hose.

  • Dycor - Model LC-D Series - Residual Gas Analyzer

    Dycor - Model LC-D Series - Residual Gas Analyzer

    The Dycor LC-D Series Residual Gas Analyzer (RGA) offers outstanding performance, yet is priced to be the most cost-effective RGA on the market. The LC-D Series instruments are constructed from materials that are compatible with Ultra High Vacuum (UHV) systems and are designed to require the very minimum in maintenance. This versatile RGA is ideally suited for use with UHV systems and equipment monitoring of semiconductor and thin film processes in...

  • Dycor - Model ProLine - Process Mass Spectrometers

    Dycor - Model ProLine - Process Mass Spectrometers

    With outstanding sensitivity, stability and unequaled clean mass separation across the whole mass range, these analyzers offer process MS at a process GC price. Available in benchtop, weatherproof and hazardous area configurations, the analyzers can sample from up to 32 inlet ports each of which can be assigned different analysis methods. Now you can afford to use MS for applications currently using GC, NIR, FTIR or multiple single component devices,...

  • ProMaxion - Model MS - Online Gas Analysis for Weatherproof or Hazardous Area Locations

    ProMaxion - Model MS - Online Gas Analysis for Weatherproof or Hazardous Area Locations

    AMETEK's ProMaxion process mass spectrometer offers real-time analysis in a reliable easy-to-use package for a wide range of industrial applications. Real-time process monitoring of up to 32 components is straightforward with ProMaxion's powerful, easy-to-use Process 2000 software. Complex overlapping spectra are handled automatically and data output directly in concentration units. Different calibration and analysis methods can be assigned to each...

  • FlarePro - Process Mass Spectrometer

    FlarePro - Process Mass Spectrometer

    Fast, Accurate Determination of Flare Gas Heat Value by Process MS. New rules for flare stack combustion from the US Environmental Protection Agency (EPA) set to take effect in early 2019 include additional monitoring and analysis requirements that make it necessary for refinery operators to quickly and accurately determine the heat values of flare stack gases. Determining the heating values of vent gas is important because sufficient combustible...

  • DyMaxion - Enclosed Ion Source Gas Analyzer

    DyMaxion - Enclosed Ion Source Gas Analyzer

    Increased sensitivity and decreased background noise are possible due to the ionizer design. An enclosed ion source operates with sample pressures as high as 10-3 torr with no need for futher pressure reduction of this differentially pumped inlet system. Higher sample pressures contain greater numbers of neutrals and more sample to ionize. With each order of magnitude increase in pressure, signal strength varies proportionally with sample density....

  • DyMaxion - Model RGA - Smart Sensor Residual Gas Analyzer

    DyMaxion - Model RGA - Smart Sensor Residual Gas Analyzer

    This “zero footprint” Smart Sensor Residual Gas Analyzer has the data acquisition and control electronics mounted directly on the sensor, and can be linked to a computer via either its RS-232 port, or RS-485 port for multiple analyzer instruments.

  • UV Vis

  • Model 4000 - Configurable Photometric Analyzer

    Model 4000 - Configurable Photometric Analyzer

    AMETEK' Process Instruments Model 4000 Photometric Analyzer is a proven choice for reliable, accurate, continuous, online photometry measurement. It is the only photometric analyzer on the market with over 40 years of actual field experience in thousands of applications. The Model 4000 was initially developed to fill various process and environmental measurement needs within the chemical industry, and later the applications were expanded to include a...

  • Model 910 - Hot/Wet Multi Gas Mass Flow CEM

    Model 910 - Hot/Wet Multi Gas Mass Flow CEM

    The AMETEK Process Instruments Model 910 is specifically configured for monitoring the stack emissions of multiple pollutants on a mass rate basis. It measures stack effluent temperature and velocity in addition to as many as five pollutant concentrations at stack conditions, enabling each pollutant's mass emission rate to be reported. With the addition of an optional zirconium oxide sensor, the Model 910 is capable of monitoring oxygen.

  • Model 914 - Continuous Emission Monitoring System

    Model 914 - Continuous Emission Monitoring System

    The  Model 914 is a built-to-order Continuous Emission Monitor (CEM) that includes all the components needed for a compliance monitoring and reporting project. The system uses dry extractive sampling techniques designed to meet government regulations for all types of compliance monitoring.

  • Model 919 - Hot/Wet Single Gas Analyzer

    Model 919 - Hot/Wet Single Gas Analyzer

    The Model 919 is specifically configured for monitoring stack emissions on a concentration basis. With the addition of an optional zirconium oxide sensor, the Model 919 is capable of monitoring oxygen. Robust and reliable analyzer, the Model 919 has no-moving-parts, UV-based measurements do not suffer from H2O and CO2 interference. This greatly simplifies sample handling and sample integrity as there is no need for sample drying. As a fully...

  • Model 920 - Hot/Wet Multi Gas CEM

    Model 920 - Hot/Wet Multi Gas CEM

    The AMETEK Western Research Model 920 is specifically configured for monitoring the stack emissions of multiple pollutants on a concentration basis. It measures as many as five pollutants at stack conditions. With the addition of an optional zirconium oxide sensor, the Model 920 is capable of monitoring oxygen.

  • Model 930 - H2S in Sulfur Pit Analyzer

    Model 930 - H2S in Sulfur Pit Analyzer

    In many sulfur recovery units, produced sulfur is stored in liquid form in sulfur pits. Operators are increasingly aware that sulfur pits present potential danger to plant personnel and overall plant safety. It is therefore critically important to monitor H2S in the vapour space of sulfur pits to ensure that it remains below the Lower Explosive Limit (LEL) (4.3% by volume). Additionally, the presence of rising concentrations of SO2 in the sulfur pit...

  • Model 931 - Single Gas H2S Analyzer (opt. + H2 and HC)

    Model 931 - Single Gas H2S Analyzer (opt. + H2 and HC)

    The Model 931 uses a sophisticated UV-VIS photometer to measure any single UV-absorbing gas species for process monitoring and control. Additional IR and thermal conductivity sensors capable of detecting non-UV absorbing species, such as CO2 and H2 can be incorporated into the design. The 931 is provided as an explosion-proof package making it suitable for most chemical and petrochemical applications.

  • Model 932 - Multi Gas H2S Analyzer (opt. + H2 and HC)

    Model 932 - Multi Gas H2S Analyzer (opt. + H2 and HC)

    The Model 932 uses a sophisticated UV-VIS photometer to measure up to five gas species for process monitoring and control for chemical processes. The Model 932 is provided as an explosion-proof package and our proprietary high-resolution UV-VIS technology which is completely free from water or hydrocarbon interference, maximizing measurement accuracy. A very flexible design, the 932 can be optionally equipped with additional sensors to add the...

  • Model 933 - H2S in Natural Gas

    Model 933 - H2S in Natural Gas

    The Model 933 is a unique UV-based photometric analyzer system for H2S analysis when present in concentrations below 100 ppm in natural gas and other applications. The analyzer responds quickly to changes in H2S concentration and it quickly self-recovers from extreme upset conditions.

  • Model 934 - Sensor Specific Gas Analyzer

    Model 934 - Sensor Specific Gas Analyzer

    The Model 934 is a rugged, analyzer adapted from the Model 931/932 UV analyzer platform for measurement of Hydrogen in Tail Gas Treating Units (TGTU) where the UV (H2S) is not required. The Model 934 analyzer system has a heated cell to avoid and hydrocarbon or water condensation.  A fully integrated AMETEK Process Instruments sample system ensures reliable dew point control without running the risk of plugging, contaminating, or flooding the...

  • Model 9900RM - Single or Multi-Component Gas Analyzer

    Model 9900RM - Single or Multi-Component Gas Analyzer

    The new Model 9900RM is a single or multi-component gas analyzer that can be used alone or as an integrated part of a continuous emissions monitoring (CEM) system. The analyzer is 19” rack-mountable and supports Modbus/RS485 and Ethernet connectivity.  This is a rugged, single or multi-gas analyzer, free of interference from water and CO2.

  • X-Ray Fluorescence

  • ASOMA - Model 682T-HP - On-Line Analysis of Sulfur

    ASOMA - Model 682T-HP - On-Line Analysis of Sulfur

    The ASOMA 682T-HP is designed for the on-line analysis of sulfur in highly viscous hydrocarbons such as crude and residual oil using XRT (X-ray Transmission) technology. This system is ideal for high temperature and pressure sample streams. With its rugged, time-proven proportional counter detector and X-ray tube source, the 682T-HP gives superb analytical precision with a sulfur limit of detection of 200 ppm. The 682T-HP key features include a fully...

  • Thermox

  • Thermox - Model WDG-V - Combustion Analyzer

    Thermox - Model WDG-V - Combustion Analyzer

    The reliable identification of low combustion oxygen in a fired heater or boiler has always been critical to the effectiveness of the Burner Management System for proper control and safety. Low emission burners and aggressive firing control points to achieve increased efficiency and emission reductions have driven the industry to tighter control measures.  But tighter control measures also hold a greater potential for combustion events. Reducing...

  • AMETEK PI - Model WDG-V Zone1 - Analyzer

    AMETEK PI - Model WDG-V Zone1 - Analyzer

    The Model WDG-V Zone 1 analyzer offers a complete solution for combustion process control and safety with redundancy and diagnostics that provide end users with digitally transmitted information via Modbus and Ethernet that can be used to implement predictive and proactive Asset Management maintenance programs.

  • THERMOX - Model WDG-IVSeries - Analyzers

    THERMOX - Model WDG-IVSeries - Analyzers

    The THERMOX Model WDG-IV analyzers measure oxygen, combustibles and methane in natural gas-fired applications. They are ideal for gas-fired power boilers or for boilers using natural gas during start-up and shutdown. With these analyzers, you can monitor oxygen and combustibles for maximum fuel efficiency. Available with Series 2000 controller. This analyzer has a close-coupled extractive design for fast response in a wide range of flue gas...

  • THERMOX - Model WDG Insitu Probe - Flue Gas Oxygen Probe

    THERMOX - Model WDG Insitu Probe - Flue Gas Oxygen Probe

    The THERMOC Model WDG Insitu flue gas oxygen probe differs from all other oxygen insitu probes. The unique inner/outer probe design facilitates removal of cell, heater and thermocouple assembly through the probe head. Once the inner probe assembly is removed, the outer probe support pipe allows straight run access to insitu filter for cleaning with compressed air. The inner probe assembly also exposes the reference side of the zirconium cell to...

  • THERMOX - Model WDG-IV UOP/RP - Oxygen Analyzer for UOP CCR Platforming Process

    THERMOX - Model WDG-IV UOP/RP - Oxygen Analyzer for UOP CCR Platforming Process

    The Model WDG UOP/RP was designed in conjunction with UOP Continuous Catalyst Regeneration process requirements for meeting the purpose of low level oxygen measurement during the regeneration cycle in which coke deposits are removed from the catalyst by oxidation. THE Model WDG UOP/RP Analyzer has a specially treated Zirconium Oxide cell which is used to survive the destructive effects of halogen-oxidation. The sensor uses a...

  • THERMOX - Model WDG-HPII Series - Flue Gas Oxygen Analyzer

    THERMOX - Model WDG-HPII Series - Flue Gas Oxygen Analyzer

    The WDG-HPII Series offers a unique chimney-effect/convective sampling technology that incorporates the advantages of insitu probe high particulate sampling with high temperature and corrosion resistance of extractive analyzers. The HPII is ideal for combustibles and oxygen measurement on applications in cement and lime kilns, foundry and metals production furnaces, coal, wood waste and heavy oil-fired boilers, black liquor recovery boilers. Available...

  • THERMOX - Model CMFA-P2000 - Portable Premix Gas/Flue Gas Analyzer

    THERMOX - Model CMFA-P2000 - Portable Premix Gas/Flue Gas Analyzer

    The CMFA-P2000, (Combustion Mix Flue Gas Analyzer), was designed specifically to meet the dual furnace combustion requirements of glass container manufacturing plants. Using a highly reactive bare platinum zirconium oxide cell, the analyzer is capable of measuring excess oxygen in post combustion flue gas or excess oxygen to excess fuel in premixed combustion samples feeding forehearth zones. The transportable two piece analysis and control...

  • THERMOX - Model CG1000 - Oxygen Analyzer

    THERMOX - Model CG1000 - Oxygen Analyzer

    The CG1000 is a portable oxygen analyzer designed for industrial and laboratory applications. It has a wide operating range (0.1 ppm to 100% O2, autoranging), a fast response to oxygen changes, and advanced electronic capabilities for easy system integration.

  • THERMOX - Model TM2000 - Net Oxygen Analyzer

    THERMOX - Model TM2000 - Net Oxygen Analyzer

    The TM2000 Net Oxygen Analyzer protects industrial processes by quickly responding to changes using an industry proven zirconium oxide sensor. It operates within a wide range of 0.1 ppm to 100% oxygen, and can accurately respond from atmosphere to low ppm oxygen levels in just seconds.  In addition, the TM2000 can detect excess combustibles process upsets in the presence of very low ppm oxygen readings. This unique benefit is particularly...

  • THERMOX - Model WDG 1200 Insitu - Flue Gas Oxygen Analyzer with Automatic Calibration & Modbus Output

    THERMOX - Model WDG 1200 Insitu - Flue Gas Oxygen Analyzer with Automatic Calibration & Modbus Output

    The WDG 1200 Insitu and the WDG 1210 Insitu are rugged, reliable flue gas analyzers for net oxygen that use industry-proven zirconium oxide sensor technology. The outer probe tube is 310 stainless steel so no abrasion shield is needed for most applications. The controller features precision temperature control for optimum stability, built-in diagnostics, and over-temperature protection. Modbus and 4-20 mA outputs are standard; automatic calibration is...

  • THERMOX - Model CEM/O2 - Oxygen Analyzer

    THERMOX - Model CEM/O2 - Oxygen Analyzer

    The CEM/O2 sensor was designed to meet the replacement and integration needs of hot-wet extractive CEM systems integrators. The sample inlet feeds a straight-run sample line with center mounted chimney-effect convection stack for continuous sampling. Compact sensor housing fits easily into CEM cabinet.

  • THERMOX - Model 120HD - Portable Hydrogen Analyzer

    THERMOX - Model 120HD - Portable Hydrogen Analyzer

    The 120HD analyzer functions as a katharometer. It operates by having two parallel tubes both of which contain gas and heating coils. The gases are examined by comparing the rate of loss of heat from the heating coils into the gas. The coils are arranged in a bridge circuit so that resistance changes due to unequal cooling can be measured.

  • Process Instruments

  • AMETEK PI - Model TDLAS 5100 HD - Gas Analyzer

    AMETEK PI - Model TDLAS 5100 HD - Gas Analyzer

    The Model 5100 HD hosts a dual laser platform. Two separate lasers are installed in the instrument, sharing a common optical path through the sample, enabling the measurement of two analytes simultaneously. This results in significant cost savings to our customers. Where the required concentrations of the analytes differ considerably such that different path lengths are required, two sample cells are used. Model 5100HD is also capable of dual stream...

  • AMETEK PI - Model TDLAS 5100 - Gas Analyzer

    AMETEK PI - Model TDLAS 5100 - Gas Analyzer

    The Model 5100 hosts a single laser platform to measure a single gas analyte. The Model 5100 can measure any one of the following gas analytes: water vapor, methane, hydrogen sulfide, carbon dioxide, and oxygen in process or flue gas. If water vapor is the measured gas analyte, methane can be monitored additionally at percent levels using the same laser.

  • AMETEK PI - Model 5000 - Process Moisture Analyzer

    AMETEK PI - Model 5000 - Process Moisture Analyzer

    The versatile AMETEK Model 5000 is a highly sensitive moisture analyzer for process applications where the continuous, reliable measurement of moisture in vapors and gases is required. The Model 5000 analyzer measures moisture on-line by monitoring the vibrational frequency change of a hygroscopically sensitized quartz crystal that is exposed alternately to wet sample and dry reference gas for 30 second periods. The reference gas is sample gas passed...

  • AMETEK PI - Model 2850 - Moisture Analyzer

    AMETEK PI - Model 2850 - Moisture Analyzer

    AMETEK’s Model 2850 Moisture Analyzer establishes a new standard in clean gas moisture analyzers: ultrafast response speed, exceptional accuracy, virtually no interferences, multigas compatibility, and on-board measurement verification. This unique combination of capabilities makes the Model 2850 the moisture analyzer of choice for monitoring process desiccant dryers, instrument air dryers, or air separators, and for industrial gas...

  • AMETEK PI - Model 5800 - Moisture Analyzer

    AMETEK PI - Model 5800 - Moisture Analyzer

    Critical moisture measurement applications include high purity gas production; olefin manufacture, storage, and transmission; semiconductor gases; and industrial gas production and quality assurance. For these applications and more, turn to AMETEK Process Instruments’ Model 5800 Moisture Analyzer. The Model 5800 offers a truly remarkable combination of performance benefits: exceptional accuracy, multi-gas compatibility, fast response...

  • AMETEK PI - Model 5812 - Moisture Analyzer

    AMETEK PI - Model 5812 - Moisture Analyzer

    Measuring moisture in natural gas is not a difficult application, but reliably measuring on a continuous basis is. Glycols and entrained compressor oils can quickly contaminate or damage most moisture sensors. In addition, many moisture analyzers have no means to detect the presence of such contamination, leading to inaccurately monitored or completely unmonitored gas streams.

  • AMETEK PI - Model 5830 - Moisture Analyzer

    AMETEK PI - Model 5830 - Moisture Analyzer

    Building upon the success of our quartz-crystal moisture measurement technology, AMETEK’s Model 5830 is an easy-to-use process moisture analyzer that offers a truly remarkable combination of performance features: exceptional accuracy, multi-gas compatibility, fast response speed, and wide measurement range.

  • AMETEK PI - Model 5910 UHP - Moisture Analyzer

    AMETEK PI - Model 5910 UHP - Moisture Analyzer

    The Model 5910 provides a quantum leap forward in performance across all measurable parameters. The 5910 is sensitive to changes in moisture concentration of less than 500 pptv. We know this because the nominal noise level is below 50 pptv. The result of these phenomenal abilities is an accuracy of better than ±100 pptv or ±10% of reading.

  • AMETEK PI - Model 5920 UHP - Moisture Analyzer

    AMETEK PI - Model 5920 UHP - Moisture Analyzer

    Building upon the success of our quartz-crystal moisture measurement technology, AMETEK’s Model 5920 is an easy-to-use process moisture analyzer that offers a truly remarkable combination of performance features: multi-gas compatibility,  exceptional accuracy, on-line verification, fast response speed, and wide measurement range. The 5920 is ideal for critical moisture measurement applications including high purity gas production and...

  • Western Research

    A wide range of standard and custom-built industrial UV-Vis photometric analyzers for various chemical composition analyses of inert, reactive, and toxic gases or liquids. Used to monitor or control: feedstock quality, reaction rates, quality control/assurance, blending analysis, pollutants, etc.

  • AMETEK PI - Model WR-888 - Sulfur Recovery Unit (SRU) Analyzers

    AMETEK PI - Model WR-888 - Sulfur Recovery Unit (SRU) Analyzers

    AMETEK Process Instruments has been the leader in tail gas analysis for over 40 years-with more than 1,100 installed model 880 NSL analyzers and more than 100 million hours of run time. The Model 888, the successor of the 880 NSL uses field-proven and highly reliable UV technology to accurately monitor the H2S and SO2 concentrations in sulfur recovery tail gas. This compact,...

  • AMETEK PI - Model 900 - Tail Gas-Air Demand Analyzer

    AMETEK PI - Model 900 - Tail Gas-Air Demand Analyzer

    In the past, conventional Claus Sulfur recovery processes were adequately controlled on the basis of ratio or excess process air.  The development of new and modified sulfur recovery processes has dramatically changed the analytical requirements placed on the tail gas analyzer.  These applications require accurate chemical concentration data over wide dynamic ranges.  Selective oxidation processes may require the analyzer to control the...

  • AMETEK PI - Model 909 - Hot/Wet Single Gas Mass Flow CEM

    AMETEK PI - Model 909 - Hot/Wet Single Gas Mass Flow CEM

    Due to compliance regulations, it is not adequate to simply know the concentration of pollutants in the stack gas emissions. A facility is required to monitor and report the mass emissions (e.g. lb/hr, kgs/day, etc.) of their processes. The Model 909 is specifically configured for monitoring stack emissions on a mass rate basis. It measures stack effluent temperature and velocity in addition to pollutant concentration at stack conditions, enabling...