Products by Metrohm AG

  • Karl Fischer Titration

    Metrohm and Karl Fischer titration: a long history of success. Looking back on half a century of experience in Karl Fischer titration, Metrohm has shaped what coulometric and volumetric water analysis are today. With groundbreaking innovations and a strong commitment to quality and precision, we have developed a range of instruments to cover any needs in titrimetric water determination. From trace levels to high water contents, from sample preparation to automation, our systems will provide

  • Metrohm - Model KF Titrando - Volumetric Karl Fischer Titrators

    Metrohm - Model KF Titrando - Volumetric Karl Fischer Titrators

    No matter whether your samples contain just trace concentrations of water or whether they are mostly water, the Titrando family of Karl Fischer titrators has got you covered. These coulometric and volumetric titrators can be customized to your requirements and offer a wealth of options to make your work easier and safer: optional software control, sample preparation and automation solutions, and many more.

  • Metrohm - Model KF Ti-Touch - Compact KF Titrator for Water Determination

    Metrohm - Model KF Ti-Touch - Compact KF Titrator for Water Determination

    KF Ti-Touch titrators offer routine water determination on a small space. Designed as easy-to-use and compact systems, they are equipped with a variety of features to make your work more comfortable: color touch screen, shortcuts for favorite methods, KF icons indicating the instrument status, and many more. The KF Ti-Touch is available as a volumetric system for determining water contents above 0.1% and as a coulometric system for low water contents...

  • Metrohm - Model 756 and 831 - Coulometers

    Metrohm - Model 756 and 831 - Coulometers

    The 756 and 831 Coulometers have gained a reputation for dependability and accuracy. These inexpensive, time-tested coulometric titrators allow you to analyze samples with low water contents (0.001 to 1%) in an easy and convenient manner.

  • Metrohm - Model 875 KF - Gas Analyzer System

    Metrohm - Model 875 KF - Gas Analyzer System

    Metrohm’s all-inclusive system for water determination in liquefied and permanent gases. This robust analyzer measures trace levels of water in a variety of gases (propane, propene, LPG, butane, refrigerants, etc.). Fully automated analysis with software control. Built-in filters for solid matter and oil residues. Predefined analytical methods.

  • Metrohm Autolab - Karl Fischer Titrator

    Metrohm Autolab - Karl Fischer Titrator

    Metrohm has reinvented volumetric Karl Fischer titration: Discover OMNIS. OMNIS is Metrohm’s new, fully integrated solution for water content determination with volumetric Karl Fischer titration. Determining water in samples has never been more convenient, safer, and easier.

  • Metrohm - Model 2.875.9050 - 875 KF Gas Analyzer without Monitor

    Metrohm - Model 2.875.9050 - 875 KF Gas Analyzer without Monitor

    The 875 KF Gas Analyzer is a completely configured analysis system. The instrument contains a computer with tiamo™ full titration software installed in addition to an 851 Titrando for automatic coulometric water content determination. Predefined methods for water content determination in liquefied and permanent gases facilitate work with the 875 KF Gas Analyzer. In addition to determining water content in gases, the system can also be used for...

  • Karl Fischer Titration - KF Titrando

  • Karl Fischer Titration - KF Ti-Touch

  • Karl Fischer Titration - KF Titrino plus

  • Karl Fischer Titration - KF Titrino Coulometer

  • Metrohm - Model MATi 04 - Automated Coulometric KF Titrations

    Metrohm - Model MATi 04 - Automated Coulometric KF Titrations

    MATi 4 is a fully automated system for coulometric KF titrations with high sample throughput. Up to 160 samples in 6 mL vials can be placed on the sample rack of the Sample Processor. The sample is pipetted into an external coulometric cell and then titrated there. The system is controlled with the tiamo™ titration software.

  • Metrohm - Model MATi 10 - Automated Volumetric KF Titrations

    Metrohm - Model MATi 10 - Automated Volumetric KF Titrations

    Fully automated system for volumetric Karl Fischer water content determination in up to 24 samples. The system is controlled with tiamo™ and consists of an 814 USB Sample Processor, a 901 Titrando and extensive accessories. The samples are weighed out into the beakers, sealed to protect against humidity and placed on the rack. Before the actual titration, they are dissolved in a defined volume of KF working medium, after which...

  • Metrohm - Model MATi 11 - Automated Volumetric KF Titration System including Sample Preparation

    Metrohm - Model MATi 11 - Automated Volumetric KF Titration System including Sample Preparation

    Fully automated system for volumetric Karl Fischer water content determination in up to 53 samples. This system is controlled with tiamo™ and consists of an 815 Robotic USB Sample Processor XL, a 901 Titrando, a Polytron PT 1300 D and extensive accessories. The samples are weighed out into beakers, sealed to protect against humidity and placed on the rack. Before the actual titration, a defined volume of KF reagent is...

  • Metrohm - Model 2.874.0010 - 874 USB Oven Sample Processor with tiamo™ Full

    Metrohm - Model 2.874.0010 - 874 USB Oven Sample Processor with tiamo™ Full

    The 874 Oven Sample Processor is used for automatic thermal sample preparation in Karl Fischer titration. The oven method is particularly suitable for samples that do not release their water until higher temperatures have been reached, for sparingly soluble samples or those that react with the KF reagent.

  • Metrohm - Model 2.874.0020 - 874 USB Oven Sample Processor Customized with tiamo™ Full

    Metrohm - Model 2.874.0020 - 874 USB Oven Sample Processor Customized with tiamo™ Full

    The 874 Oven Sample Processor is used for automatic thermal sample preparation in Karl Fischer titration. The oven method is particularly suitable for samples that do not release their water until higher temperatures have been reached, for sparingly soluble samples or those that react with the KF reagent. This instrument can be modified to match customer-specific sample vessels. Please contact your Metrohm representative for further...

  • Metrohm - Model 2.874.0110 - 874 USB Oven Sample Processor

    Metrohm - Model 2.874.0110 - 874 USB Oven Sample Processor

    The 874 Oven Sample Processor is used for automatic thermal sample preparation in Karl Fischer titration. The oven method is particularly suitable for samples that do not release their water until higher temperatures have been reached, for sparingly soluble samples or those that react with the KF reagent.

  • Metrohm - Model 2.890.0110 - 890 Titrando with Touch Control

    Metrohm - Model 2.890.0110 - 890 Titrando with Touch Control

    The 890 Titrando is a high-end titrator for volumetric Karl Fischer titrations. The instrument is equipped with a built-in buret drive, four MSB connectors, a galvanically separated measuring interface and a USB connector. The Touch Control operating unit with touch-sensitive screen for controlling the Titrando, the 803 Ti Stand and a 10 mL exchange unit are included in the scope of delivery.

  • Metrohm - Model 2.890.0210 - 890 Titrando with tiamo™ Light

    Metrohm - Model 2.890.0210 - 890 Titrando with tiamo™ Light

    The 890 Titrando is a high-end titrator for volumetric Karl Fischer titrations. The instrument is equipped with a built-in buret drive, four MSB connectors, a galvanically separated measuring interface and a USB connector. The tiamo™ light titration software for controlling the Titrando, the 803 Ti Stand and a 10 mL exchange unit are included in the scope of delivery.

  • Metrohm - Model 2.851.0010 - 851 Titrando with Generator Electrode with Diaphragm

    Metrohm - Model 2.851.0010 - 851 Titrando with Generator Electrode with Diaphragm

    Coulometer including generator electrode with diaphragm and 801 Magnetic Stirrer. Coulometry is the ideal method for water determination in liquids, solids and gases when it comes to water determination in the trace range (10 µg to 10 mg absolute water). In addition, coulometry is an absolute method and thus no titer determination is necessary. Coulometric titrations are carried out easily and quickly with the 851 Titrando. Recommended measuring...

  • Metrohm - Model 2.852.0050 - 852 Titrando with Generator Electrode with Diaphragm

    Metrohm - Model 2.852.0050 - 852 Titrando with Generator Electrode with Diaphragm

    Coulometer including generator electrode with diaphragm, 801 Magnetic Stirrer and complete volumetric titration cell. Coulometry is the ideal method for water determination in liquids, solids and gases when it comes to water determination in the trace range (10 µg to 10 mg absolute water). In addition, coulometry is an absolute method and thus no titer determination is necessary. Recommended coulometry measuring range: 10 µg - 200 mg...

  • Metrohm - Model 2.851.0110 - 851 Titrando with Generator Electrode without Diaphragm

    Metrohm - Model 2.851.0110 - 851 Titrando with Generator Electrode without Diaphragm

    Coulometer including generator electrode without diaphragm. Coulometry is the ideal method for water determination in liquids, solids and gases when it comes to water determination in the trace range (10 µg to 10 mg absolute water). In addition, coulometry is an absolute method and thus no titer determination is necessary. Coulometric titrations are carried out easily and quickly with the 851 Titrando. Recommended measuring range: 10 µg -...

  • Metrohm - Model 2.860.0010 - 860 KF Thermoprep for Thermal Sample Preparation

    Metrohm - Model 2.860.0010 - 860 KF Thermoprep for Thermal Sample Preparation

    The 860 KF Thermoprep is designed for thermal sample preparation in Karl Fischer titration. Numerous substances cannot be analysed by direct Karl Fischer titration as they are not soluble, react with the Karl Fischer reagent or release their water only very slowly or not until heated to high temperatures. Using tightly sealed sample vials, the sample is inserted in the oven. The samples can be subsequently analysed by any volumetric or...

  • Metrohm Karl Fischer - Model 2.901.0010 - 901 Titrando for the Modern Titration Laboratory

    Metrohm Karl Fischer - Model 2.901.0010 - 901 Titrando for the Modern Titration Laboratory

    The Karl Fischer Titrando for the modern titration laboratory. In addition to the Karl Fischer mode (KFT), the high-end titrator is also equipped with the SET mode and can thus perform titrations to a predefined endpoint. 'iTrode ready': As a result of the high-resolution, galvanic measuring interface – now also for the first time with additional digital measuring input for the intelligent 'iTrodes' electrodes – it is additionally possible...

  • Metrohm - Model 2.852.0150 - 852 Titrando with generator electrode without diaphragm

    Metrohm - Model 2.852.0150 - 852 Titrando with generator electrode without diaphragm

    Coulometer including generator electrode without diaphragm and complete volumetric titration cell. Coulometry is the ideal method for water determination in liquids, solids and gases when it comes to water determination in the trace range (10 µg to 10 mg absolute water). In addition, coulometry is an absolute method and thus no titer determination is necessary. Recommended coulometry measuring range: 10 µg - 200 mg absolute water. The 852...

  • Metrohm - Model 2.885.0010 - 885 Compact Oven Sample Changer

    Metrohm - Model 2.885.0010 - 885 Compact Oven Sample Changer

    The 885 Compact Oven Sample Changer is used for thermal sample preparation in Karl Fischer titration. In the oven the samples can be heated up to 250°C. The moisture contained in the sample evaporates and is transported by a dry carrier gas into the titration cell, where the analysis takes place.

  • Metrohm - Model 2.136.0200 - KF Evaporator

    Metrohm - Model 2.136.0200 - KF Evaporator

    The KF Evaporator is used for sample preparation in Karl Fischer titration by means of azeotropic distillation. As with the oven method, the water is separated from the sample matrix. Because the sample itself remains in the evaporation chamber, the titration vessel and the electrodes are not contaminated. Furthermore, unwanted side reactions and matrix effects are avoided.

  • Metrohm Polytron - Model PT 1300 D - Homogenizer

    Metrohm Polytron - Model PT 1300 D - Homogenizer

    Polytron PT 1300 D - Metrohm version; Homogenizer that can be controlled directly by tiamo™ or Touch Control. The Polytron PT 1300 D is comprised of a monitoring instrument and a drive. The coupling system on the drive permits the simple and rapid replacement of the aggregates without additional tools. Solid samples can be pulverized without difficulty. The instrument is however outstandingly suitable for ensuring thorough mixing in viscous...

  • Metrohm - Model 2.917.0110 - 917 Coulometer with Generator Electrode without Diaphragm

    Metrohm - Model 2.917.0110 - 917 Coulometer with Generator Electrode without Diaphragm

    The 917 Coulometer is a compact titrator for coulometric water determination in accordance with Karl Fischer. ''Reduced to the max'' – operating module, stirrer and pump are integrated in the 917 Coulometer for rapid reagent replacement. This saves a great deal of space on the laboratory table. Recommended measuring range: 10 µg…200 mg absolute water. Coulometry is the ideal method for water content determination in liquids, solids...

  • Metrohm - Model 2.917.0010 - 917 Coulometer with Generator Electrode with Diaphragm

    Metrohm - Model 2.917.0010 - 917 Coulometer with Generator Electrode with Diaphragm

    The 917 Coulometer is a compact titrator for coulometric water determination in accordance with Karl Fischer. ''Reduced to the max'' – operating module, stirrer and pump are integrated in the 917 Coulometer for rapid reagent replacement. This saves a great deal of space on the laboratory table. Recommended measuring range: 10 µg…200 mg absolute water; Coulometry is the ideal method for water content determination in liquids, solids...

  • Metrohm - Model 2.915.0110 - Compact Titrator for Karl Fischer Titration

    Metrohm - Model 2.915.0110 - Compact Titrator for Karl Fischer Titration

    'Reduce to the max' – that is the concept behind the 915 KF Ti-Touch. The new compact titrator for Karl Fischer titration from Metrohm offers the maximum in the class of stand-alone systems for routine analysis. Burets, stirrer, dosing unit and Touch Control are integrated in a single, compact system unit. This saves a great deal of space on the laboratory table. The 915 KF Ti-Touch now also fulfills FDA Regulation 21 CFR, Part 11. This means...

  • Metrohm - Model 2.899.0010 - 899 Coulometer with Generator Electrode with Diaphragm

    Metrohm - Model 2.899.0010 - 899 Coulometer with Generator Electrode with Diaphragm

    Thanks to the integrated stirrer, the 899 Coulometer takes up less space on the laboratory table than a sheet of DIN A4 paper. Although small and compact, the coulometer does not compromise on performance. Water contents can be determined with precision down to trace levels. Indicator electrode and generator electrode with diaphragm are included in the scope of delivery. Recommended measuring range: 10 µg - 200 mg absolute water. Coulometry is...

  • Metrohm - Model 2.899.0110 - 899 Coulometer with Generator Electrode without Diaphragm

    Metrohm - Model 2.899.0110 - 899 Coulometer with Generator Electrode without Diaphragm

    Thanks to the integrated stirrer, the 899 Coulometer takes up less space on the laboratory table than a sheet of DIN A4 paper. Although small and compact, the coulometer does not compromise on performance. Water contents can be determined with precision down to trace levels. Indicator electrode and generator electrode without diaphragm are included in the scope of delivery. Recommended measuring range: 10 µg - 200 mg absolute water. Coulometry...

  • Metrohm - Model 2.831.0110 - 831 KF Coulometer with Generator Electrode without Diaphragm

    Metrohm - Model 2.831.0110 - 831 KF Coulometer with Generator Electrode without Diaphragm

    nexpensive coulometer including titration cell with generator electrode without diaphragm for water content determination down to trace levels. This coulometer has become indispensable in many laboratories thanks to its reliability, its backlit graphical display, the multi-language dialog and the simplicity of its operation. The clear display provides information regarding the relevant titration parameters and unambiguous indication of the progress of...

  • Metrohm - Model 2.870.0010 - KF Titrator for Volumetric Water Content Determination

    Metrohm - Model 2.870.0010 - KF Titrator for Volumetric Water Content Determination

    The inexpensive 870 KF Titrino plus is a KF titrator for volumetric water content determination. With it, water contents from a few ppm to 100% can be determined reliably and precisely in solid, liquid and gaseous samples. With its user interface, which is tailored to routine users, the 870 KF Titrino plus is so simple to operate that only brief orientation periods are required. It is the ideal titrator for routine determinations, also because of its...

  • Metrohm - Model 2.831.0010 - 831 KF Coulometer with Generator Electrode without Diaphragm

    Metrohm - Model 2.831.0010 - 831 KF Coulometer with Generator Electrode without Diaphragm

    Inexpensive coulometer including titration cell and generator electrode with diaphragm for water content determination down to trace levels. This coulometer has become indispensable in many laboratories thanks to its reliability, its backlit graphical display, the multi-language dialog and the simplicity of its operation. The clear display provides information regarding the relevant titration parameters and unambiguous indication of the progress of...

  • Ion Chromatography

  • Metrohm - Model 940 Professional IC Vario - Modular High-performance System for Ion Chromatography

    Metrohm - Model 940 Professional IC Vario - Modular High-performance System for Ion Chromatography

    The limits of ion chromatography have yet to be reached. If you want to push them, the 940 Professional IC Vario is your solution of choice. Engineered for research and sophisticated method development, the 940 Professional IC Vario provides you with the ultimate flexibility you expect from an ion chromatograph. Experience the versatility of the 940 Professional IC Vario and put together the system for your application.

  • Metrohm - Model 2.889.0010 - 889 IC Sample Center

    Metrohm - Model 2.889.0010 - 889 IC Sample Center

    The 889 IC Sample Center is a robust Autosampler for high sample throughput, optimized for the challenges of the modern analytic laboratory. It works in accordance with the x-y-z principle and a syringe control with high resolution for precise sample injection. A double needle system enables the penetration of vessel caps and septa. A PEEK injection valve completes the automation system of the 889 IC Sample Center. It is the appropriate automation...

  • Metrohm - Model Eco IC - Ion Chromatography System

    Metrohm - Model Eco IC - Ion Chromatography System

    Discover Eco IC, an ion chromatography system that focuses on the essentials while not compromising on quality, robustness, and reliability. Eco IC has been developed to enable more users to benefit from this technique. Whether you need to perform routine water analysis or you’re looking for an instrument for higher education, Eco IC comes with all the components you need. In addition, you can also save time and reduce work by getting an...

  • Metrohm - Inline Sample Preparation (MISP) for Difficult Sample Matrices

    Metrohm - Inline Sample Preparation (MISP) for Difficult Sample Matrices

    Metrohm Inline Sample Preparation (MISP) puts an end to manual sample preparation for ion chromatography. MISP stands for methods developed by Metrohm that allow you to fully automate the preparation of even the most challenging samples. Not only will you increase sample throughput but also improve accuracy and reproducibility of analyses and results.

  • Metrohm - Model 2.889.0020 - 889 IC Sample Center – Cool

    Metrohm - Model 2.889.0020 - 889 IC Sample Center – Cool

    The 889 IC Sample Center – cool is the appropriate automation solution when you have only a very small amount of sample. In comparison with the 889 IC Sample Center, it possesses in addition a cooling function and is thus the ideal sample changer for biochemically relevant or thermally unstable samples.

  • Metrohm - Model IC-MS and IC-ICP/MS - Coupling

    Metrohm - Model IC-MS and IC-ICP/MS - Coupling

    Combining IC with an electrospray ionization mass spectrometer (ESI-MS) or an inductively coupled plasma mass spectrometer (ICP-MS) solves even complex separation problems while achieving outstanding sensitivities and selectivities. These so-called hyphenated techniques provide valuable information for unambiguous peak identification and are less prone to matrix influences than IC with conductivity detection.

  • Metrohm - Model 2.136.0740 - LPG Module

    Metrohm - Model 2.136.0740 - LPG Module

    The LPG Module is a sample injection system for liquefied gases. The module is controlled automatically and moves the respective quantities of gas to the combustion oven for combustion. This product from Analytik Jena has been specially optimized for coupling with ion chromatographs.

  • Metrohm - Model TitrIC Vario pro III - Professional Hyphenated IC and Titration System with Lockable Sample Vessels

    Metrohm - Model TitrIC Vario pro III - Professional Hyphenated IC and Titration System with Lockable Sample Vessels

    TitrIC Vario pro III – The professional solution with closed sample vessels. Fully automatic system for direct measurement of temperature, conductivity and pH value, the titrimetric determination of p and m values, the determination of cations including calcium and magnesium, as well as anions by ion chromatography. The sample changer is equipped with the DisCover function for automatic sample vessel cover removal. The system consists of 856...

  • Metrohm - Model 2.136.0700 - Combustion Module (Oven + ABD)

    Metrohm - Model 2.136.0700 - Combustion Module (Oven + ABD)

    The Combustion Module (Oven + ABD ) enables sample digestion during pyrolysis and oxidation of all types of flammable samples. The Combustion Module is comprised of the combustion oven and the Auto Boat Driver (automatic sample introduction). Both are products made by Analytik Jena which have been optimized specially for coupling with ion chromatographs.

  • Metrohm - Model MMS 5000 - Autosampler

    Metrohm - Model MMS 5000 - Autosampler

    Autosampler MMS 5000 made by Analytik Jena for use with the Metrohm Combustion IC for fully automatic analysis of liquid and solid samples. To adapt the modular Multi-Matrix sampler to the correct sample type, either the liquids kit (6.7303.000) of the solids kit (6.7302.000) must be used.

  • Metrohm - Model 2.136.0730 - Combustion Module (Oven + LPG/GSS)

    Metrohm - Model 2.136.0730 - Combustion Module (Oven + LPG/GSS)

    The Combustion Module (Oven + LPG/GSS) enables sample digestion during the pyrolysis of liquefied gases and gases under pressure. The Combustion Module (Oven + LPG/GSS) is comprised of the combustion oven and the LPG/GSS module. Both are products of Analytik Jena which have been optimized specially for coupling with ion chromatographs.

  • Metrohm - Model 2.136.0720 - LPG/GSS Module

    Metrohm - Model 2.136.0720 - LPG/GSS Module

    The LPG/GSS Module is a sample injection system for either liquefied gases or gases under enhanced pressure. The module is controlled automatically and moves the respective amounts of gas to the combustion oven for combustion. The Analytik Jena product has been optimized specially for coupling with ion chromatographs.

  • Metrohm - Model TitrIC Vario pro II - Hyphenated IC and Titration System for Comprehensive Anion and Cation Analysis

    Metrohm - Model TitrIC Vario pro II - Hyphenated IC and Titration System for Comprehensive Anion and Cation Analysis

    Fully automatic system for direct measurement of temperature, conductivity and pH value, the titrimetric determination of p and m values, the determination of cations including calcium and magnesium, as well as anions by ion chromatography. The system consists of the 856 Conductivity Module, two 800 Dosinos, 802 Stirrer (rod stirrer), 905 Titrando, 815 Robotic USB Sample Processor XL, one 930 Compact IC Flex Oven/Deg without suppression and one 930...

  • Metrohm - Model TitrIC Vario pro I - Basic Hyphenated System for IC and Titration

    Metrohm - Model TitrIC Vario pro I - Basic Hyphenated System for IC and Titration

    Fully automatic system for direct measurement of temperature, conductivity and pH value; the titrimetric determination of p value, m value, calcium and magnesium and the determination of anions by ion chromatography. The system consists of the 856 Conductivity Module, four 800 Dosinos, 802 Stirrer (rod stirrer), 905 Titrando, 815 Robotic USB Sample Processor XL and 930 Compact IC Flex Oven/SeS/PP/Deg with sequential suppression and the 'iDetector'...

  • Metrohm - Model 2.136.0710 - Auto Boat Drive (ABD)

    Metrohm - Model 2.136.0710 - Auto Boat Drive (ABD)

    The Auto Boat Drive (ABD) automatically guides the sample boats into the combustion oven. The sample can be put into the boat manually or using an appropriate sampler. This product made by Analytik Jena has been specially optimized for coupling with ion chromatographs.

  • Metrohm - Model 920 - Absorber Module

    Metrohm - Model 920 - Absorber Module

    The 920 Absorber Module combines the Combustion Module with the ion chromatograph. The 920 Absorber Module ensures that the gaseous compounds of the analytes are dissolved and channeled to the IC. It is responsible for the entire Liquid Handling. In addition to Combustion IC, it can also be used for gas analysis.

  • Ion Chromatography - MISP

    Metrohm Inline Sample Preparation (MISP) puts an end to manual sample preparation for ion chromatography. MISP stands for methods developed by Metrohm that allow you to fully automate the preparation of even the most challenging samples. Not only will you increase sample throughput but also improve accuracy and reproducibility of analyses and results.

  • Metrohm - Model ProfIC Vario 11 Anion - Professional IC Vario System

    Metrohm - Model ProfIC Vario 11 Anion - Professional IC Vario System

    The Professional IC Vario system with Metrohm Inline Neutralization, Metrohm's intelligent inline preconcentration technique and Inline Matrix Elimination and sequential suppression and conductivity detection enables the analysis of anions in complex matrices from the ultratrace down to the mg/L range.

  • Metrohm - Model 2.940.1140 - 940 Professional IC Vario ONE/HPG

    Metrohm - Model 2.940.1140 - 940 Professional IC Vario ONE/HPG

    The 940 Professional IC Vario ONE/HPG is the intelligent IC instrument without suppression with binary high-pressure gradient. It can be extended with the 942 Extension Modules to up to a quaternary gradient system. The instrument can be used with any separation and detection methods.

  • Metrohm - Model 2.940.1250 - 940 Professional IC Vario ONE/ChS/LPG

    Metrohm - Model 2.940.1250 - 940 Professional IC Vario ONE/ChS/LPG

    The 940 Professional IC Vario ONE/ChS/LPG is the intelligent IC instrument with chemical suppression and low-pressure gradient. An 800 Dosino can be used for the regeneration of the suppressor. The instrument can be used with any separation and detection methods.

  • Metrohm - Model 2.940.1240 - 940 Professional IC Vario ONE/ChS/HPG

    Metrohm - Model 2.940.1240 - 940 Professional IC Vario ONE/ChS/HPG

    The 940 Professional IC Vario ONE/ChS/HPG is the intelligent IC instrument with chemical suppression and binary high-pressure gradient. It can be extended with the 942 Extension Modules to up to a quaternary gradient system. An 800 Dosino can be used for the regeneration of the suppressor. The instrument can be used with any separation and detection methods.

  • Metrohm - Model 2.940.1120 - 940 Professional IC Vario ONE/Prep 2

    Metrohm - Model 2.940.1120 - 940 Professional IC Vario ONE/Prep 2