64 products found

products

  • Gases - Calibration

    The accuracy and precision of an air quality or emission monitoring system can only be optimised with the use of repeatable and traceable calibration equipment. Ecotech provides automatic gas dilution calibrators, calibration gas standards and high performance zero air generators for the calibration of all gas analysers in a monitoring system. The dilution calibrator enables the mixing of source gas, from calibration gas cylinders, with zero air, from the zero air generator, in order to gene

  • Ecotech - Model Serinus Cal 3000 - Gas Dilution Calibrator

    Ecotech - Model Serinus Cal 3000 - Gas Dilution Calibrator

    The Serinus Cal 3000 includes all the features from its Serinus Cal 1000 and Serinus Cal 2000 stablemates, adding an ozone photometer for the accurate creation and delivery of ozone concentrations when calibrating ozone analysers. The photometer accurately and continuously measures the ozone concentration to control output of the internal ozone generator, providing an accurate ozone source for routine ozone calibration.

  • Gases - Integrated Systems

  • Ecotech - Ambient Air Quality Monitoring Systems

    Ecotech - Ambient Air Quality Monitoring Systems

    Ecotech’s air monitoring systems are custom designed to best meet each application’s unique demands. We talk to our customers about their specific needs and tailor the ambient air quality monitoring system accordingly. For instance: A customer of ours requires a system in a warm environment, where power costs for air conditioning are a high percentage of operating costs.

  • Ecotech - Continuous Emissions Monitoring Systems

    Ecotech - Continuous Emissions Monitoring Systems

    We offer a complete solution for continuous emission monitoring, utilising the extractive dilution monitoring method. With over 30 years of experience in the design, construction, installation, commissioning and maintenance of Continuous Emission Monitoring Systems (CEMS), you can rely on us for your CEMS needs.

  • Ecotech - Trace/Background Air Quality Monitoring Systems

    Ecotech - Trace/Background Air Quality Monitoring Systems

    Ecotech are specialists in the design, construction, installation, commissioning and maintenance of trace/background air quality monitoring stations. The analysers used in our trace systems are approved as trace monitoring analysers by the USEPA and are extensively used in USEPA NCore monitoring systems.

  • Gases - Research & Scientific

  • Ecotech - Model Spectronus - FTIR Trace Gas and Isotope Analyser

    Ecotech - Model Spectronus - FTIR Trace Gas and Isotope Analyser

    The Spectronus analyser provides simultaneous measurements of multiple greenhouse gas species with high repeatability and excellent precision without the need for frequent gas calibrations. The Spectronus analyser combines a Fourier Transform Infrared (FTIR) spectrometer, multi-pass gas sample cell and a high performance detector. It uses sophisticated software for fully automated operation and real-time quantitative analysis of trace gases in air or...

  • Particulates - Aerosol Research Instruments

  • Ecotech - Model Aurora 1000 - Integrating Nephelometer

    Ecotech - Model Aurora 1000 - Integrating Nephelometer

    Easy to use and maintain, the Aurora 1000 lowers the cost of ownership for aerosol light scattering, visibility and particulate monitoring instrumentation. The Aurora 1000 uses a single wavelength LED for light scattering coefficient and visibility measurements. Ecotech, through collaboration with globally renowned atmospheric research institutes, now provide the scientific community with the most advanced commercially available...

  • Ecotech - Model Aurora 2000 - PM Correlating Nephelometer

    Ecotech - Model Aurora 2000 - PM Correlating Nephelometer

    The Aurora 2000 PM Correlating Nephelometer is part of the ‘new generation’ nephelometers using a single wavelength and an BETA monitor to measure aerosol light scattering and derive particulate concentrations. The Aurora 2000 enables the calculation of a correlation factor based on a PM2.5 reference method which is then used to derive EVERY MINUTE a PM2.5 concentrations along with the usual light scattering. The correction factor can be...

  • Ecotech - Model Aurora 4000 - Polar Nephelometer

    Ecotech - Model Aurora 4000 - Polar Nephelometer

    The Aurora 4000 polar nephelometer is the only commercially available polar nephelometer in the world. The polar nephelometer goes beyond simple integrated nephelometers and allows much more detailed measurements. The Aurora 4000 polar nephelometer uses a programmable backscatter shutter which allows the user to set up to 17 customisable angles between 10º and 90º. The Aurora 4000 polar nephelometer provides greater insight into light...

  • Ecotech - Model ACS1000 - Aerosol Conditioning System

    Ecotech - Model ACS1000 - Aerosol Conditioning System

    Studying the hygroscopic properties of aerosol particles offers insights into their effect on the earth’s radiative balance. By simultaneously exposing aerosol particles to different relative humidity, Ecotech’s Aerosol Conditioning System (ACS 1000) enables the effect of water uptake on the particles’ physical properties to be compared and measured by two real-time instruments simultaneously.

  • Particulates - Ambient

  • Ecotech - Model HiVol 3000 - High Volume Air Sampler

    Ecotech - Model HiVol 3000 - High Volume Air Sampler

    The HiVol 3000 particulate sampler performs remote unattended sampling of PM2.5, PM10 or TSP along with basic meteorological parameters. The HiVol 3000 incorporates advanced programming functions and electronic volumetric flow control to maintain a consistent flow and collect a truly representative sample of particulate matter. Optional attachments allow the sampler to measure wind speed and direction which can then be used to trigger sector...

  • Ecotech - Model HiVol 3000 PUF - High Volume Air Sampler

    Ecotech - Model HiVol 3000 PUF - High Volume Air Sampler

    The HiVol 3000 PUF Sampler provides a flexible platform for sampling organic compounds and monitoring basic meteorological parameters. The PUF utilises poly-urethane foam (PUF) to trap organic vapors in addition to collecting particulate matter and store it in a sterile environment for later analysis.

  • Ecotech - Model HiVol 3000 XAD - High Volume Air Sampler

    Ecotech - Model HiVol 3000 XAD - High Volume Air Sampler

    The HiVol 3000 XAD Sampler provides a flexible platform for sampling organic compounds and monitoring basic meteorological parameters. The XAD sampler collects a wider variety of compounds (than a PUF sampler) on a hydrophobic polyaromatic resin (XAD).

  • Ecotech - Model Protinus 1000 - Real-Time Dust Monitor

    Ecotech - Model Protinus 1000 - Real-Time Dust Monitor

    The Protinus 1000 provides a particulate monitor ideally suited for continuous monitoring around mines, quarries, construction and other dust generating activities. The Protinus 1000 utilises size speicifc inlets to ensure accurate real-time dust measurements at suspended solids, PM10 or PM2.5 size fractions. he Protinus 1000 can be combined with weather sensors to provide wind speed and direction data, Rh and ambient temperature. The monitor provides...

  • Ecotech - Model Spirant BAM - Particulate Monitor

    Ecotech - Model Spirant BAM - Particulate Monitor

    The Spirant BAM automatically measures and records airborne particulate concentrations using the beta ray attenuation method. It is designated by the U.S. EPA as Federal Equivalent Method for PM10 and PM2.5 monitoring.

  • Particulates - Integrated Systems

  • Ecotech - Shelters

    Ecotech - Shelters

    Ecotech offers a wide range of shelter types and configurations that can be customised to your exact needs. We have experience in all environments from the hot tropical climate of Malaysia to the freezing cold of Antarctica.

  • Ambient Air Quality Monitoring Systems

  • Ecotech - Model Serinus 10 - Ozone Analyzer

    Ecotech - Model Serinus 10 - Ozone Analyzer

    The Serinus 10 Ozone (O3) analyser delivers precise and reliable performance at excellent value. It uses proven non-dispersive ultraviolet (UV) absorption technology to measure O3 in ambient air (LDL 0.5 ppb, range 0-20 ppm).

  • Ecotech - Model Serinus 30 - Carbon Monoxide Analyser

    Ecotech - Model Serinus 30 - Carbon Monoxide Analyser

    The Serinus 30 Carbon Monoxide analyser delivers precise and reliable performance at excellent value. It uses proven NDIR gas filter correlation technology to measure CO in ambient air (LDL 40 ppb, range 0-200ppm).

  • Ecotech - Model Serinus 40 - Oxides of Nitrogen Analyser

    Ecotech - Model Serinus 40 - Oxides of Nitrogen Analyser

    The Serinus 40 Oxides of Nitrogen analyser delivers precise and reliable performance at excellent value. It uses proven chemiluminescence technology to measure NO, NO2 and NOx in ambient air (LDL 0.4 ppb, range 0-20 ppm).

  • Ecotech - Model Serinus 44 - NO/NO2/NOX/NH3 Multi Gas Analyzer

    Ecotech - Model Serinus 44 - NO/NO2/NOX/NH3 Multi Gas Analyzer

    The Serinus 44 analyser delivers precise and reliable performance at excellent value. It uses proven chemiluminescence technology and an external thermal catalytic converter to measure NO, NO2, NOxand NH3 in ambient air (LDL 0.4ppb, Range 0-20ppm). The Serinus range of analysers has been designed using our experience and knowledge gained from operating large air quality monitoring networks for...

  • Ecotech - Model Serinus 51 - SO2/H2S Analyser

    Ecotech - Model Serinus 51 - SO2/H2S Analyser

    The Serinus 51 analyser delivers precise and reliable performance at excellent value. It combines pulsed fluorescence detection with an internal catalytic converter to sequentially measure H2S and SO2 in the range of 0-2/0-20 ppm respectively with a detection limit of 0.3 ppb. The Serinus range of analysers has been designed using our experience and knowledge gained from operating large air quality monitoring networks for more than 35 years. The...

  • Ecotech - Model Serinus 55 - Hydrogen Sulphide (H2S) Analyzer

    Ecotech - Model Serinus 55 - Hydrogen Sulphide (H2S) Analyzer

    The Serinus 55 Hydrogen Sulphide analyser (H2S) analyser delivers precise and reliable performance at excellent value. It uses proven UV fluorescent radiation technology and an internal thermal catalytic converter to measure H2S in ambient air (LDL

  • Ecotech - Model Serinus 57 - Total Reduced Sulphides Analyser

    Ecotech - Model Serinus 57 - Total Reduced Sulphides Analyser

    The Serinus 57 Total Reduced Sulphides analyser delivers precise and reliable performance at excellent value. It uses proven UV fluorescent radiation technology and a thermal converter to measure TRS in ambient air (LDL 0.3ppb, Range 0-10 ppm). TRS is measured by converting TS to SO2 using the external HTO1000 converter and then measuring the resultant SO2 using the pulsed fluorescence technique.

  • Ecotech - Model Serinus 56 - Total Sulphides Analyser

    Ecotech - Model Serinus 56 - Total Sulphides Analyser

    The Serinus 56 Total Sulphides analyser delivers precise and reliable performance at excellent value. It uses proven UV fluorescent radiation technology and an external thermal converter to measure TS in ambient air. The Serinus range of analysers has been designed using our experience and knowledge gained from operating large air quality monitoring networks for more than 35 years. The result: instruments that integrate...

  • Ecotech  - Model Serinus 60 - Direct Nitrogen Dioxide Analyser

    Ecotech - Model Serinus 60 - Direct Nitrogen Dioxide Analyser

    Ecotech presents the latest addition to the Serinus range: The Serinus 60 NO₂ analyser with Cavity Attenuated Phase Shift (CAPS) spectroscopy technology. This technology allows direct measurement of nitrogen dioxide (NO2), rather than an indirect calculation from a chemiluminescence analyser. Using a modulated blue LED light source, the detector measures the phase shift attributable to the level of NO2 in...

Products by Opsis AB

  • Ambient Air Quality Monitoring

    We know the solution for any air quality monitoring situation. Our monitoring systems, approved by international institutes and authorities, are found in a range of applications around the world.

  • Opsis - Open-Path UV & FTIR DOAS Systems

    Opsis - Open-Path UV & FTIR DOAS Systems

    OPSIS AQM systems measure multiple gases in real time over an open path. Using the DOAS (Differential Optical Absorption Spectroscopy) technique, the system is non-contact, with fast response. One system can be configured to monitor NO, NO2, SO2, O3, BTX, NH3, CO, CO2, HF, H2O, CH4, Hg, HCl, among other gaseous compounds. A basic system includes an analyser, an emitter/receiver set, and an optical fibre cable. The system has been tested and approved...

  • Opsis - Mobile Systems

    Opsis - Mobile Systems

    OPSIS offers a wide range of shelter models and configurations to guarantee the optimal operation environment for your measurement equipment. We have experience in all environments, from hot and humid, to cold.

  • Opsis - Model LD500 - Laser Diode Gas Analyser (AQM)

    Opsis - Model LD500 - Laser Diode Gas Analyser (AQM)

    OPSIS LD500 Analyser is the central unit in the laser diode gas monitoring system. It can house up to four laser diode heads. Each head is a complete laser control and data sampling system. The laser diode gas analyser provides very fast monitoring of a range of gaseous compounds. Several gases can be monitored and a multiplexer offers several monitoring paths. Typical compounds are carbon monoxide (CO), carbon dioxide (CO2), hydrogen fluoride (HF),...

  • Opsis - Model HG200 - Mercury Analyser System

    Opsis - Model HG200 - Mercury Analyser System

    The Opsis HG200 mercury analyser is designed for ambient air quality monitoring, for detecting mercury indoors, and for monitoring in plants. The HG200 analyser monitors elementary mercury, Hg(0), concentrations in the ambient air, from health-hazardous down to the environmental background levels.

  • Opsis - Model SM200 - PM10 Particulate Monitor System

    Opsis - Model SM200 - PM10 Particulate Monitor System

    The PM10 monitor version of OPSIS’ SM200 particulate monitor provides accurate and reliable automatic measurements of PM10 particulate fraction concentrations in ambient air, as well as sampling of the PM10 particulate fraction for subsequent manual analysis.

  • Opsis - Model SM200 - PM2.5 Particulate Monitor System

    Opsis - Model SM200 - PM2.5 Particulate Monitor System

    The PM2.5 monitor version of OPSIS’ SM200 particulate monitor offers accurate and reliable automatic measurements of PM2.5 particulate fraction concentrations in ambient air, and sampling of the PM2.5 particulate fraction for later manual analysis.

  • Opsis - Model DL256 - Data Logger (AQM)

    Opsis - Model DL256 - Data Logger (AQM)

    OPSIS data logger system is designed for data acquisition applications. The data logger can handle analogue and digital input and output signals as well as serial communication. The hardware of the DL256 is based on modules. It is therefore easy to configure the system to meet a wide range of requirements, and the system can be upgraded by adding modules.

  • Opsis - Model WT256 - Web Transfer

    Opsis - Model WT256 - Web Transfer

    The WT256 collects data from OPSIS analysers and data loggers and pushes the data via FileTransfer Protocoll (FTP) or via file copy to a temporary storage site on a TCP/IP based network, such as the Internet. The data is downloaded automatically from the network storage site to one or several users, utilizing a download service installed on the target computer. Once downloaded, further data processing can be done with software for data presentation...

  • Continuous Emissions Monitoring

  • OPSIS - Cross-Stack UV & FTIR DOAS Systems

    OPSIS - Cross-Stack UV & FTIR DOAS Systems

    OPSIS CEM systems measure multiple emissions or process gases in real time in situ. Using the DOAS (Differential Optical Absorption Spectroscopy) technique, the system is non-contact, with fast response.

  • Opsis - Model 400CS - Cross-Stack System

    Opsis - Model 400CS - Cross-Stack System

    System 400CS is a cost-effective, high-performance monitoring package, designed for power plants and waste to energy plants. The measurements are based on the FTIR (Fourier Transform Infrared Spectroscopy) and/or 

  • Opsis - Model 400FL - Fast-Loop System

    Opsis - Model 400FL - Fast-Loop System

    System 400FL combines the benefits of hot wet extractive and in situ. The gas is moved at high speed in a bypass line. No filter or probe is used and the measurement takes place in a non-contact measurement cell.

  • Opsis - Model 400HWE - Hot Wet Extractive System

    Opsis - Model 400HWE - Hot Wet Extractive System

    System 400HWE Hot Wet Extractive is based on OPSIS UV/FTIR DOAS system giving fast response and best possible performance for all gases. The high resolution FTIR system is free from interference from all gases including water.

  • Opsis - Model LD500 - Laser Diode Gas Analyser (CEM)

    Opsis - Model LD500 - Laser Diode Gas Analyser (CEM)

    OPSIS LD500 Analyser is the central unit in the laser diode gas monitoring system. It can house up to four laser diode heads. Each head is a complete laser control and data sampling system. A built-in PC with LCD display controls the function of the instrument.

  • Opsis - Model M800 - Marine System

    Opsis - Model M800 - Marine System

    The DNV-GL approved System M800 measures SO2 and CO2 using the reference methods NDUV and NDIR. A light emitter and receiver creates a light path across the internal diameter of the stack. From the receiver, the light is guided in an optical fiber to the analyser.

  • Opsis - Model O2000 - Oxygen Monitor

    Opsis - Model O2000 - Oxygen Monitor

    The OPSIS O2000 oxygen monitor is designed to monitor oxygen concentrations in industrial applications such as continuous emissions monitoring (CEM) and process control. It has been given a ruggedized design (IP65 protection) allowing it to operate under tough conditions in aggressive flue gas environments.

  • Opsis - Model ER060L-EEx - Emitter and Receiver Systems

    Opsis - Model ER060L-EEx - Emitter and Receiver Systems

    The ER060L-EEx emitter and receiver set, together with Opsis LD500 laser diode gas analyser, is designed for gas monitoring in explosion classed areas Zone 1 and 2. The monitoring set creates a light path across the internal diameter of a stack or duct for an Opsis emissions monitoring system. Light is generated by the analyser, passed through the emitter and projected to the receiver.

  • OPSIS - Model DL256 - Data Logger (CEM)

    OPSIS - Model DL256 - Data Logger (CEM)

    OPSIS data logger system is designed for data acquisition applications. The data logger can handle analogue and digital input and output signals as well as serial communication.

  • OPSIS - Model WT256 - Web Transfer

    OPSIS - Model WT256 - Web Transfer

    The WT256 web transfer collects data from OPSIS analysers and data loggers and pushes the data via FileTransfer Protocol (FTP) or via file copy to a temporary storage site on a TCP/IP based network, such as the Internet. The data is downloaded automatically from the network storage site to one or several users, utilizing a download service installed on the target computer. Once downloaded, further data processing can be done with software for data...

  • Opsis - Dilution Analysers

    Opsis - Dilution Analysers

    OPSIS offers compact analyser packages for monitoring NOX, SO2, CO and O2 in many different kinds of stack gas applications.

  • Opsis - Model RD100 - Real Driving Emissions System

    Opsis - Model RD100 - Real Driving Emissions System

    Our RD100 Real Driving Emissions system is an accurate and reliable monitoring system that can measure the emissions from car exhaust in real life conditions. The RD100 system is mounted on a car and measures the real driving emissions during an ordinary drive.

Products by Arizona Instrument LLC

  • Jerome - Model 860 - Electrochemical Sensor Hydrogen Sulfide Monitor

    Jerome - Model 860 - Electrochemical Sensor Hydrogen Sulfide Monitor

    Compact, rugged and intrinsically safe, the Jerome 860 was manufactured from 2003 until 2014. It utilized durable electrochemical sensor technology to monitor low levels of hydrogen sulfide in contained or hard to reach areas. The Jerome 860 was calibrated for a measurement range of 0 to 200 ppm, but was capable of measuring sporadic spikes of up to 1000 ppm H2S. It was durable, compact, water resistant and intrinsically safe, making it ideal for...

Products by Tethys Instruments SAS

  • Probes

  • Tethys Instruments - General Purpose PH Sensor Probes

    Tethys Instruments - General Purpose PH Sensor Probes

    Tethys General Purpose pH Sensor with ¾”NPT thread on both front & back is a heavy-duty pH probe with Ryton body suitable for many industrial water application. Mounting thread on both front and back allow for in-pipe (continuous measurement) or submersible installations of pH Sensor. This pH sensor offers excellent chemical and impact resistance.

  • Tethys Instruments - PH SENSOR Differential Probe

    Tethys Instruments - PH SENSOR Differential Probe

    Tethys Differential pH Sensor with 1 ½”NPT thread on both front & back is a heavy-duty pH probe with Ryton Polyphenylene Sulfide body suitable for many industrial water application. The differential design provides unsurpassed accuracy by virtually eliminating ground loops. Mounting thread on both front and back allow for in-pipe (continuous measurement) or submersible installations of pH Sensor. You can replace the salt bridge and...

  • Tethys Instruments - ORP Sensor Probe

    Tethys Instruments - ORP Sensor Probe

    Tethys General Purpose ORP Sensor with ¾”NPT thread on both front & back is a heavy-duty ORP probe with Ryton body suitable for many industrial water applications. Mounting thread on both front and back allow for in-pipe (continuous measurement) or submersible installations of ORP Sensor. This ORP sensor offers excellent chemical and impact resistance.

  • Tethys Instruments - Dissolved Oxygen Probe

    Tethys Instruments - Dissolved Oxygen Probe

    Tethys Process Optical DO Probe is based on proven Luminescent Optical Technology suitable for most industrial application. It provides full featured performance, replaceable sensor caps, and long life. Mounting thread on both front and back allow for in-pipe (continuous measurement) or submersible installations of DO probe. Optical DO probe is suitable for measurement of dissolved oxygen measurement in various water and waste water application.

  • Tethys Instruments - Dissolved Oxygen Probe Auto Cleaning

    Tethys Instruments - Dissolved Oxygen Probe Auto Cleaning

    Tethys Process Optical DO Probe is based on proven Fluorescence Optical Technology suitable for most industrial application. It is rugged, without replacement sensor cap and having auto-cleaning feature. It is designed for submersible mounting in open basin. Optical DO probe is suitable for measurement of dissolved oxygen measurement in various water and waste water application.

  • Tethys Instruments - Total Suspended Solids Probe

    Tethys Instruments - Total Suspended Solids Probe

    Tethys Total Suspended Solid (TSS) Probe operate on the principle of single gap light absorption as a means of detecting the presence of suspended solids. The sensors incorporate self-cleaning optics via air or water jet. The application involves measurement of total suspended solids concentration from Mixed Liquor Suspended Solid (MLSS), Return Activated Sludge (RAS), Waste Activated Sludge (WAS), clarifier effluent and plant effluent.

  • Tethys Instruments - Turbidity Sensor Probe

    Tethys Instruments - Turbidity Sensor Probe

    Tethys Turbidity probes are based on Nephelometric Method (ISO 7027 – EN 27027). A light beam is sent to the sample through an optical lens. The 90 degree scattered light by suspended particle is collected by the probe through a second lens and it is converted in an electric signal proportional to the turbidity of the sample. The probe uses an infrared light and the measuring is not affected by the color of the sample. They are suitable for...

  • Tethys Instruments - Chlorine Sensor Probe

    Tethys Instruments - Chlorine Sensor Probe

    Tethys Chlorine Sensor is based on proven amperometric measurement technology. It is factory calibrated and zero calibration is not required. It’s long life membrane cap is replaceable with refillable gel electrolyte. It is suitable for measurement of residual chlorine (free or total) in various Industrial water and waste water application.

  • Tethys Instruments - Conductivity Probe

    Tethys Instruments - Conductivity Probe

    Tethys Conductivity Sensor with ¾”NPT thread is a heavy-duty probe with Polypropylene body suitable for many industrial water application. Mounting thread allow for in-pipe (flow through) installations of conductivity sensor. These conductivity sensor offers excellent chemical and impact resistance.

Products by Cooper Environmental Services

  • Cooper Environmental - Model PTFE - Filter Tape

    Cooper Environmental - Model PTFE - Filter Tape

    Cooper Environmental’s success in measuring low concentrations of metallic elements is dependent on using the highest quality PTFE filter tape possible. Our filter tape has extremely low contamination levels combined with very high flow capability, resulting in a very high quality ambient measurement filter.

  • Cooper Environmental - Model QAG 825 - Quantitative Aerosol Generator (QAG)

    Cooper Environmental - Model QAG 825 - Quantitative Aerosol Generator (QAG)

    The QAG creates an aerosol of known concentration by nebulizing a solution. The resulting droplets are carried out of the generation area to a drying chamber where they are dried to particles. The aerosol exiting the drying chamber contains known concentrations of analytes calculated from the QAG’s input parameters. The reference aerosol produced by the QAG is traceable-to-NIST standards and can be used to challenge and evaluate the accuracy,...