Hi-Tech Detection Systems (HTDS)

Hi-Tech Detection Systems (HTDS)

684 products found

Products by

  • Instruments - Single Channel Potentiostat

  • PalmSens - Model 4 - Battery Powered Potentiostat

    PalmSens - Model 4 - Battery Powered Potentiostat

    Our flagship instrument, the PalmSens4, is a USB and battery powered Potentiostat, Galvanostat, and optional a Frequency Response Analyser (FRA) for Electrochemical Impedance Spectroscopy (EIS). The PalmSens4 has a large potential range (-5V to 5V or -10V to 10V) and current range (100 pA to 10 mA) with a high resolution and low noise. The economical PalmSens4 is a complete laboratory instrument but its compact and rugged design makes it also...

  • EmStat - Small and Low Cost Potentiostat

    EmStat - Small and Low Cost Potentiostat

    EmStat is a small and low cost potentiostat with research grade capabilities. It has eight current ranges from 1 nA to 100 mA (EmStat3+) full scale, with a minimum resolution of 1 pA. It provides the most relevant electroanalytical measurement techniques. Its price makes it a popular choice for educational purposes. The EmStat USB powered potentiostats are the smallest research grade electrochemical interfaces available on the market. The...

  • EmStat Blue - Small and Low Cost Potentiostat

    EmStat Blue - Small and Low Cost Potentiostat

    EmStat Blue is a small USB and battery powered potentiostat with integrated Bluetooth. It is ideal for mobile sensor applications. EmStat Blue is a small and low cost potentiostat with research grade capabilities. It has eight current ranges from 1 nA to 100 mA (EmStat3+ Blue) full scale, with a minimum resolution of 1 pA. It provides the most relevant electroanalytical measurement techniques and is used with the PSTrace software or with PStouch for...

  • Instruments - Multi Channel Potentiostat

  • MultiPalmSens - Model 4 - Flexible Multi Channel Potentiostats

    MultiPalmSens - Model 4 - Flexible Multi Channel Potentiostats

    The MultiPalmSens4 is a flexible multi-channel potentiostat, galvanostat and impedance analyzer which you can fully tailor to your requirements and budget. The MultiTrace software allows for using each channel individually or simultaneously or running a sequence of automated tasks on each channel. Each channel provides an additional auxiliary port for controlling peripherals or...

  • MultiEmStat - Versatile Multi-Channel Potentiostat

    MultiEmStat - Versatile Multi-Channel Potentiostat

    The MultiEmStat is a versatile multi-channel potentiostat with 4, 8 or 12 independent EmStat potentiostats. The channels can perform experiments independently of each other. The MultiEmStat is conveniently connected by means of a single USB connection and controlled by MultiTrace. Each potentiostat has eight (EmStat3) or nine (EmStat3+) current ranges: 1 nA to 10 mA/100 mA with a resolution...

  • EmStat - Model 4WE - Multi-Channel Potentiostat

    EmStat - Model 4WE - Multi-Channel Potentiostat

    A polypotentiostat with 4 working electrodes, that makes parallel measuring of multiple electrodes in one electrochemical cell possible. With this polypotentiostat one electrochemical cell can be equipped with 1, 2, 3 or 4 working electrodes and all of these will be measured parallel. The EmStat3 4WE consists of a standard EmStat3 potentiostat and additionally three polypotentiostat (bipotentiostat-like) modules. All techniques supported...

  • Instruments - Powered Potentiostat with Integrated Multiplexer

  • EmStat - Model MUX8-R2 - Powered Potentiostat with Integrated Multiplexer

    EmStat - Model MUX8-R2 - Powered Potentiostat with Integrated Multiplexer

    The EmStat can be combined with a multiplexer forming one integrated instrument to perform measurements with multiple electrode systems. With the MUX8-R2 connecting arrays or other setups made of up to eight working electrodes in two or three electrode cell types is possible. If more channels are required, one or more MUX-R2 can be stacked to the EmStatMUX to add up to 128 channels.

  • Accessories - Multiplexer

  • Accessories - Differential Electrometer Amplifier

  • PalmSens - Differential Electrometer Amplifier

    PalmSens - Differential Electrometer Amplifier

    The PalmSens Differential Electrometer Amplifier (DEA) is a general purpose input amplifier. It can be used as a floating voltage amplifier with differential input and single output to the auxiliary port of PalmSens. It is easily connected via the D-Sub port of the PalmSens and by two 2 mm banana receptacles for the signal input. The change of a potential difference can be amplified and monitored.

Products by ENVEA

  • Process - Flow Measurement

  • ENVEA - Model DensFlow - Flow Metering in Dense-Stream

    ENVEA - Model DensFlow - Flow Metering in Dense-Stream

    The measuring system for continuous flow metering in dense-stream conveying and high levels of throughput. Reliable flow metering in pneumatic dense-stream. Unlimited throughput volumes can be measured. optionally pressure-resistant up to 25 bar. Installation creates no obstacle in the profile, hence no dead spots in which residue can form. Measurement independent of the flow speed of the material. Simple retrofitting. Maintenance-free. Contactless...

  • Process - Flow Detection

  • ENVEA - Model FlowJam-A - Material Flow Monitoring on Flexible Hoses

    ENVEA - Model FlowJam-A - Material Flow Monitoring on Flexible Hoses

    Material flow monitoring on flexible hose lines for small quantities. FlowJam A is a sensor which has been specially developed for monitoring the flow of solids conveyed by hose lines. The system can be applied to hose lines made of non-conducting materials such as plastic or rubber with external diameters of between 2 and 10 mm.

  • Process - Moisture measurement

  • ENVEA - Model M-Sens WR - Online Residual Moisture Measurement

    ENVEA - Model M-Sens WR - Online Residual Moisture Measurement

    Sensor for continuous moisture measurement in dry bulk solids. Sensors for continuous moisture measurement and installation on conveyor belts, screw feeder or hoppers. Two types of sensor-technology to cover a wide range of applications. Both sensors penetrate the product for most reliable measurements.

  • Process - Velocity measurement

  • ENVEA - Model SpeedFlow 2.0 - Velocity Measurement for Solids

    ENVEA - Model SpeedFlow 2.0 - Velocity Measurement for Solids

    Continous speed measurement for solids usable in free fall and pneumatics. Especially designed for continuous measurement of velocity of solids and particles such as granulates, powders and dusts, which are transported in free fall or in pneumatic transport. Uses triboelectric correlation technology.

  • Process - Level Monitoring

  • Process - Emissions Gas Monitors

  • ENVEA - Model LAS 300 RK - Extractive TDLAS Gas Analyzer

    ENVEA - Model LAS 300 RK - Extractive TDLAS Gas Analyzer

    High precision measurements of selective compounds such as: HF, HCl, NH3, O2, NO, CO and H2O. Other gases on request. Ideal for applications which require reliable and specific measurements, this gas monitor is suitable for monitoring ppb and ppm concentrations in emissions, ambient. Air or process monitoring. It uses rapid laser tuning and direct absorption spectroscopy to achieve very stable results.

  • ENVEA - Model LAS 300 XD - In-Situ Cross-Duct TDLAS Analyzer

    ENVEA - Model LAS 300 XD - In-Situ Cross-Duct TDLAS Analyzer

    TDL monitor for in-situ non-invasive measurement of NH3 & H2O, HCl & H2O, HF as well as low or high concentrations of CO and O2 in process or CEMS applications. The Tunable Diode Laser Spectroscopy (TDLS) is the perfect technology to use when you are looking for a selective measurement and a fast response time on some gas components as NH3, HCL, HF or even O2 when conditions are too rough for standard O2 Zirconia In-Situ analysers.

  • Process - Gas Monitors - NO

  • ENVEA - Model TOPAZE 32M - Heated CLD NOx Analyzer

    ENVEA - Model TOPAZE 32M - Heated CLD NOx Analyzer

    Single reaction chamber version for the monitoring of NO or NOx, or dual chamber for NO, NOx and NO2 measurements. Exist in 2 different versions: TOPAZE 52M-S : NO or NOx monitoring. TOPAZE 52M-D : NO-NOx and NO2 simultaneous monitoring.

  • Process - Filter Performance Monitors

  • ENVEA - Model DUST ALARM 40 - Filter Damage Monitoring

    ENVEA - Model DUST ALARM 40 - Filter Damage Monitoring

    DUST ALARM 40 was specially developed to monitor clean sides after filters reliable and without time delay regarding filter breaks: immediate detection of filter damages. to avoid process-induced DustEx-areas. detects all dust types. usable in clean gas and dust channels. very simple and fast retrofitting. simple, icon-driven menu. 2 independent alarm set points. expandable to 4 ... 20 mA output (trend signal).

  • Process - Broken Bag Detection

  • ENVEA - Model Dusty C - Compact Sensor for Broken Bag Detection

    ENVEA - Model Dusty C - Compact Sensor for Broken Bag Detection

    Continuously monitors particulate flow for signs of filter damage or broken filter bags. Compact and cost effective. The Dusty C has been specially developed to monitor clean sides after filters with high reliability and without time delay for filter breaks. It can be used in metallic ducts in which dust particles will be detected in the gas flow. Its area of application begins at dust levels of 0.1 mg/m3.

  • ENVEA - Model Dusty - Broken Bag Detection

    ENVEA - Model Dusty - Broken Bag Detection

    Cost effective broken bag detection. A simple solution to identify failure of a fabric filter baghouse, cartridge filters or cyclones.Ideally suited to applications from 0.1 mg/m3, it provides an immediate alarm in case of a filter break.

  • Process - Dust Monitors

  • ENVEA - Model PCME VIEW 580 - Dynamic Opacity Dust Monitor

    ENVEA - Model PCME VIEW 580 - Dynamic Opacity Dust Monitor

    Stand alone Cross Stack optical dust monitor suitable for measuring emissions after electrostatic precipitators and stacks without filtration systems. Used for emissions measurement (mg/m³) after electrostatic precipitators and baghouses or Process control applications. Advanced sensor design includes automatic drift (zero and span) checks.

  • ENVEA - Model PCME VIEW 273 - ElectroDynamic Dust Monitor

    ENVEA - Model PCME VIEW 273 - ElectroDynamic Dust Monitor

    Multi-sensor dust monitor for indicative emissions trending in industrial stacks after bag filters, cartridge filters, cyclones and process driers, where regulatory approvals are not necessary. Advanced Probe Electrification featuring long term data logging for process trend analysis and reporting.

  • ENVEA - Model PCME VIEW 820 - ElectroDynamic Dust Monitor

    ENVEA - Model PCME VIEW 820 - ElectroDynamic Dust Monitor

    Certified Multi-sensor dust monitor – category 1 under ATEX / IECEx – for indicative emissions trending and measurement in hazardous zone and in dry processess with elevated pressures. Advanced Probe Electrification featuring long term data logging for process trend analysis and reporting.

  • ENVEA - Model PCME VIEW 800 - ElectroDynamic Multi-Sensor Dust Monitor

    ENVEA - Model PCME VIEW 800 - ElectroDynamic Multi-Sensor Dust Monitor

    Multi-Sensor Dust Monitor certified to category 1 under ATEX / IECEx designed for indicative emissions trending and measurement in challenging hazardous zone. Advanced Probe Electrification technology, perfectly adapted for particulate monitoring after bag filters, cartridge filters, cyclones and process driers, where regulatory approvals are not necessary.

  • ENVEA - Model PCME VIEW 370 - ElectroDynamic Dust Monitor

    ENVEA - Model PCME VIEW 370 - ElectroDynamic Dust Monitor

    Multi-sensor dust monitor designed for high quality emission measurement in industrial stacks after bag filters, cartridge filters, cyclones and process driers. Advanced Probe Electrification Multi-sensor dust monitor designed for high quality emission measurement in industrial stacks where regulatory approvals are not necessary.

  • ENVEA - Model ProSens - Dust Measurement After Filters

    ENVEA - Model ProSens - Dust Measurement After Filters

    Provides continuous measurement values for dust concentration as a trend signal or absolute values. The ProSens has been specially developed to carry out reliable dust measurement on clean sides after filters. The measuring device provides measurement values for dust concentration, either as a trend signal or as absolute values (after calibration) for emission measurement.

  • ENVEA - Model PCME LEAK LOCATE 320 - Filter Damage and Leak Monitoring

    ENVEA - Model PCME LEAK LOCATE 320 - Filter Damage and Leak Monitoring

    Electrodynamic filter damage and leakage monitoring of industrial multi chamber filter systems: proactive multi chamber filter monitoring, identification of upcoming filter damages, identification of the filter chamber affected by filter breakage, reduction of material-, downtime- and maintenance costs, flue-gas temperatures up to 150 °C (optional 250 °C), for dry applications, 4 sensors inclusive, expandable up to 32 sensors, digital inputs...

  • Process - Particle Size Monitoring

  • ENVEA - Model Paddy - Particle Size Monitoring

    ENVEA - Model Paddy - Particle Size Monitoring

    Paddy has been developed to supply a trending information of pulverization. It measures changes in particle size for instance to detect screen breaks. Paddy is insensitive against contaminations and works without a bypass.

  • Process - Mercury Instruments

  • Emissions & Process - Gas Monitors

  • ENVEA - Model SM-4 - Total Mercury Emissions Monitor in Stack Flue Gases

    ENVEA - Model SM-4 - Total Mercury Emissions Monitor in Stack Flue Gases

    Continuous, accurate and reliable measurement of total mercury emissions, even in very low concentrations and within complex matrices (SO2, NOx, HCl, etc.). With over 20 years experience, Mercury Instruments (part of ENVEA Group) were the first to develop mercury monitors and mercury analyzers using a dry thermocatalytic method instead of wet chemistry. The SM-4 Mercury Monitor is QAL1 certified and is ready to meet future regulatory ...

  • Emissions - Particulate CEMS

  • ENVEA - Model PCME QAL 360 - QAL1 Approved Back Scatters Particulate CEM

    ENVEA - Model PCME QAL 360 - QAL1 Approved Back Scatters Particulate CEM

    TUV QAL1 and MCERTS Approved, Stand alone or networked system option Particulate CEM providing high quality emission measurement for dust concentrations from industrial processes. Having a 0–7.5 mg/m³ certification range, the QAL 360 sensor can be used at low or high dust levels meeting the tightened minimum emission limit value of 5 mg/m³ for Large Combustion Plant specified in the Industrial Emissions...

  • ENVEA - Model PCME STACK 181 - PS11 Capable Forward Scatter Particulate CEM

    ENVEA - Model PCME STACK 181 - PS11 Capable Forward Scatter Particulate CEM

    US EPA PS11 compliant ProScatter™ particulate CEM providing high quality emission measurement for low dust concentrations from industrial processes. Utilising the patented ProScatterTM Forward Scatter measurement technique for measuring particulate concentration levels, typically between 0.06 mg/m3 to 300 mg/m3, this measurement technique offers improved levels of performance which make the PCME STACK 181 very suitable for use as a PM CPMS or PM...

  • ENVEA - Model PCME QAL 182 WS - Particulate CEM for Wet Gas Streams

    ENVEA - Model PCME QAL 182 WS - Particulate CEM for Wet Gas Streams

    QAL1 approved ProScatterTM particulate CEM for the extractive sampling and measurement of particulate in saturated wet gas streams. Continuous Particulate Monitoring for saturated wet stack applications typically found after wet scrubbers, wet electrostatic precipitators and wet flue gas desulphurisation plant.

  • Emissions - Mercury Instruments

  • ENVEA - Model SM-4 Mobile - Modular Mercury Stack Gas Monitor QAL 1 Certified

    ENVEA - Model SM-4 Mobile - Modular Mercury Stack Gas Monitor QAL 1 Certified

    Technically identical to the SM-4, this device is ideal for mercury determination at varying sites. The SM-4 Mobile by Mercury Instruments has been developed on the basis of the well proven SM-4 mercury stack gas monitor. Its measurement principle and technique, its thermocatalytic reactor, the detector and the sample probe are identical with those of the stationary SM-4.

  • Emissions - Permanent Samplers

  • ENVEA - Model Amesa-D - Dioxins & Furans Permanent Sampler

    ENVEA - Model Amesa-D - Dioxins & Furans Permanent Sampler

    Continuous dioxin and furan emission monitoring by long-term sampling. TÜV and MCERTs certified, ETV EPA approved. The AMESA-D utilizes the water cooled probe method with Isokinetic sampling system coupled with XAD-II adsorbent cartridge for Long-term sampling of dioxins (PCDD), furans (PCDF) and other persistent organic contaminant (POPs). AMESA-D is the most utilized dioxin monitoring system worldwide in all industries.

  • Emissions - Sampling Systems

  • ENVEA - Model SEC BOX - Stack Gas Sampling System

    ENVEA - Model SEC BOX - Stack Gas Sampling System

    The dry extractive SEC system dries the gas sample at the sampling point, eliminating the necessity of an expensive heated sampling line. It uses an exclusive high performance permeation technique, designed to meet almost all gas sample conditions. Ideal for highly soluble and corrosive gases. Optional built-in temperature & velocity sensors or STACKFLOW 200 flow meter on the same flange.

  • Emissions - Engine Exhausts Monitoring

  • ENVEA - Model LGD 2M - Laser Gas Detection Module NH3 (TDLS)

    ENVEA - Model LGD 2M - Laser Gas Detection Module NH3 (TDLS)

    Rack 3U monitor using the TDL extractive technology to measure online the NH3 pre and/or post catalyst: SCR (Selective Catalytic Reduction) or SNCR (Selective Non-Catalytic Reduction) ENVEA is offering Laser Gas Detection (LGD) modules with exceptional advantages and value for the customer. Tunable Diode Laser Spectrometry (TDLS), enhanced by proprietary technology, is used for the measurement of CO2, NH3, CH4, HCl, (H2O).

  • ENVEA - Model Mini DeNOx - Cabinet Heated Turnkey Gas Analysis System

    ENVEA - Model Mini DeNOx - Cabinet Heated Turnkey Gas Analysis System

    Heated Turnkey Gas Analysis System ideally suited for fast, continuous and simultaneous measurements of NH3 and NOx in DeNOx applications (SCR and SNCR). In DeNOx systems using urea injection with ammonia (NH3) as a reducing agent, the flow rate and control of NH3 must be continuously adjusted and controlled to prevent excess NH3 emissions (slip), to reduce environmental impact and cost of reagents. To optimize this process, it is essential to use an...

  • Ambient - Air Quality Gas Monitors - O3

  • ENVEA - Model Cairnet 2015 - Autonomous Networks of Sensor-Based Mini-Stations

    ENVEA - Model Cairnet 2015 - Autonomous Networks of Sensor-Based Mini-Stations

    Real-time standalone and networkable air-monitoring station containing up to four Cairsens® microsensors and cellular communication within a waterproof & solar powered enclosure. Following in real-time any given pollutant emissions data directly from your office, via your computer, smartphone or tablet? All the data centralized in the Cloud, with minimum operating costs (no maintenance, no visit on site to retrieve the data…)? Cairnet...

  • ENVEA - Model O342e e-Series - Ozone analyzer O3

    ENVEA - Model O342e e-Series - Ozone analyzer O3

    LED based, UV Photometric Ozone Analyzer providing accurate, stable and repeatable O3 measurements in the range of 0-500 ppb or 0-10 ppm. Eco-designed, reference air quality monitor using patented technology. QAL1 certified by the TUV, US-EPA approved.

  • Ambient - Air Quality Gas Monitors - SO2

  • ENVEA - Model AF22e e-Series - Sulfur dioxides Analyzer SO2

    ENVEA - Model AF22e e-Series - Sulfur dioxides Analyzer SO2

    UV Fluorescence gas monitor offering excellent performances for the monitoring of SO2 in the range 0-10 ppm or 0-1 ppm. Eco-designed, reference air quality monitor, QAL1 certified by the TÜV, US-EPA approved. Utilizes the standard method for the measurement of sulfur dioxides(EN 14212). With its ultra low power consumption & 24 V supply (option), the AF22e is the sole SO2 monitor on the market able to measure without being connected to the...

  • Ambient - Air Quality Gas Monitors - NO/NO2/NOx

  • ENVEA - Model AS32M - CAPS Nitrogen Dioxide Analyzer NO2

    ENVEA - Model AS32M - CAPS Nitrogen Dioxide Analyzer NO2

    Gas monitor for fast, precise, direct and continuous measurement of NO2 concentrations in the range 0-1000 ppb. Visible (450 nm) absorption measurement using patented Cavity Attenuated Phase Shift (CAPS) technology. QAL1 certified by the TÜV, US-EPA approved. Fast and direct measurement of the sample – no chemical conversion required, no Toxic Gas Emissions”.

  • Ambient - Air Quality Gas Monitors - VOC

  • ENVEA - Model VOC72e - Volatil Organic Compounds Analyzer BTEX

    ENVEA - Model VOC72e - Volatil Organic Compounds Analyzer BTEX

    Gas chromatography (GC) coupled with a PID detector. VOC monitor QAL1 certified to EN 14662-3 standard for benzene measurement. Compact and fully automated analyser providing equal performance to the laboratory chromatographs; particularly well-suited for fixed or mobile ambient air quality monitoring stations. Standard measured compounds: Benzene, Toluene, Ethylbenzene, m+p-Xylene, o-Xylene, 1-3 Butadiene (other compounds on request).

  • Ambient - Hg Monitors - Mercury

  • ENVEA - Model Mercury Tracker-3000 XS - All-in-One Portable Real-Time Hg Monitor

    ENVEA - Model Mercury Tracker-3000 XS - All-in-One Portable Real-Time Hg Monitor

    Very small, ultra-light, with on-board GPS, data logger, battery pack and color TFT display for very comfortable and easy mercury monitoring in ambient air and other gases. Portable mercury monitoring and detection is made easy with the Mercury Tracker 3000 XS. Lightweight, rugged construction and compact, the instrument is perfect for indoor and outdoor screening of mercury concentration in ambient air and detecting mercury...

  • ENVEA - Model MMS - Automatic Mercury Monitoring in Air and Gases

    ENVEA - Model MMS - Automatic Mercury Monitoring in Air and Gases

    The MMS basically comprises a multiplexer-valve unit and a highly accurate and selective mercury detector (VM-3000 Vapor Monitor) for measurements in air and other gases. Each mercury on-line system will differ in sample characteristics as well as installation conditions and operating environment. We have the experience to design systems that fully meet the requirements of your particular mercury monitoring task.

  • Ambient air quality - Particulate monitors - PM10 / PM2.5

  • ENVEA - Model MP101M - Continuous, Automatic Suspended Particulate Monitor

    ENVEA - Model MP101M - Continuous, Automatic Suspended Particulate Monitor

    PM10, PM2.5 and PM1 fine dust concentration measurement in the range 0-10,000 μg/m3 using the Standard Reference Method. The MP101M particulate analyzer uses the standard ISO 10473 beta gauge measurement method for the continuous measurement of the concentration of fine dust in ambient air. The instrument is certified equivalent to the reference method in accordance with the EN12341 European standards for measuring PM10 and PM2.5...

  • ENVEA - Model MP101M with OPM (Optical Particulate Monitor) - Automatic & Real-Time Particulate Monitor

    ENVEA - Model MP101M with OPM (Optical Particulate Monitor) - Automatic & Real-Time Particulate Monitor

    Hybrid monitor utilizing ISO 10473 SRM Method & optical technology for Automatic & Real-Time measurement of PM10, PM2.5 and PM1 fine dust. The standard Beta gauge measurement Method ISO 10473 of the MP101M analyzer allows, when used with the patented optical technology of the OPM module, the continuous and simultaneous measurement of fine dust. Combination of both technologies provide a real-time indication of particles for PM10, PM2.5 and PM1...

  • Ambient air quality - Particulate Monitors

  • ENVEA - Model PM162M - Automatic Sequential Particulate Sampler

    ENVEA - Model PM162M - Automatic Sequential Particulate Sampler

    Designed to automatically sample particulates on filters using a TSP, PM10, PM2.5 or PM1 inlet. PM162M is a sequential automatic sampling device for particulate matter in the ambient air. The particles are sampled at constant flow rate (1 m3/h or 2.3 m3/h) and collected on filters for gravimetric weighing and possible physicochemical laboratory analysis.

  • Ambient - Air quality monitoring & Laboratory Mercury Instruments

  • ENVEA - Model UT-3000 NG - Mobile Mercury Ultratrace Analyzer for Natural Gas

    ENVEA - Model UT-3000 NG - Mobile Mercury Ultratrace Analyzer for Natural Gas

    Perfectly adapted to monitor the efficiency of different Mercury Removal Units (MRUs) in natural gas processing plants. Each mercury on-line system will differ in sample characteristics as well as installation conditions and operating environment. We have the experience to design systems that fully meet the requirements of your particular mercury monitoring task.

  • ENVEA - Model MMS-NG - Automatic Mercury Monitoring in Natural Gas

    ENVEA - Model MMS-NG - Automatic Mercury Monitoring in Natural Gas

    Automatic systemdesigned for continuous mercury monitoring in natural gas even in hazardous zones (ATEX, IEC-Ex). Each mercury on-line system will differ in sample characteristics as well as installation conditions and operating environment. We have the experience to design systems that fully meet the requirements of your particular mercury monitoring task.

  • ENVEA - Model UT-3000 - Total Gaseous Mercury (TGM) Ultratracer

    ENVEA - Model UT-3000 - Total Gaseous Mercury (TGM) Ultratracer

    Measuring of Total Gaseous Mercury (TGM) in air and other gases. Reliable for measurements at ultra-trace levels (sub-ng/m³) according to EN 15852. The UT-3000 operates automatically. All functions are controlled by an embedded microprocessor. When measurements are carried out, all parameters and results are stored in the integrated data logger. With standard settings the data logger has a recording capacity of 5000 measurements (approx. 2...

  • Ambient - Odors detection & Air quality monitoring Micro-Sensors

  • ENVEA - Model Cairsens PM - Miniature Solution for Real-Time Continuous PM1, PM2.5 & PM10 Monitoring

    ENVEA - Model Cairsens PM - Miniature Solution for Real-Time Continuous PM1, PM2.5 & PM10 Monitoring

    The last generation of Cairsens micro-sensors for Particulate Matters (PM) monitoring operates without any influence from moisture in ambient air. They measure PM1 and PM10 concentrations, with increased precision for PM2.5. The Cairsens allows a year of continuous maintenance-free operation, even in highly polluted and humid atmospheres. Thanks to its robust and miniature design, it is fully compatible with ENVEA’s turnkey AQMS station Cairnet....

  • ENVEA - Model Cairsens nmVOC - Miniature Solution for Real-Time Continuous nmVOC Monitoring

    ENVEA - Model Cairsens nmVOC - Miniature Solution for Real-Time Continuous nmVOC Monitoring

    The Cairsens© sensor allows specific pollutant measurement comparable to reference methods. The high quality sensors are renowned worldwide by our customers looking for the newest technologies in air quality monitoring. They offer precise and reliable measurement, and are calibrated using a reference-standard value.  They come with a unique calibration certificate and don’t need any more calibration after installation during their...

  • ENVEA - Model Cairsens NH3 - Miniature Solution for Real-Time Continuous NH3 Monitoring

    ENVEA - Model Cairsens NH3 - Miniature Solution for Real-Time Continuous NH3 Monitoring

    The Cairsens© sensor allows specific pollutant measurement comparable to reference methods. The high quality sensors are renowned worldwide by our customers looking for the newest technologies in air quality monitoring. They offer precise and reliable measurement, and are calibrated using a reference-standard value.  They come with a unique calibration certificate and don’t need any more calibration after installation during their...

  • ENVEA - Model Cairsens H2S / CH4S - Miniature Solution for Real-Time Continuous H2S / CH4S Monitoring

    ENVEA - Model Cairsens H2S / CH4S - Miniature Solution for Real-Time Continuous H2S / CH4S Monitoring

    The Cairsens© sensor allows specific pollutant measurement comparable to reference methods. The high quality sensors are renowned worldwide by our customers looking for the newest technologies in air quality monitoring. They offer precise and reliable measurement, and are calibrated using a reference-standard value.  They come with a unique calibration certificate and don’t need any more calibration after installation during their...

  • ENVEA - Model Cairsens CO - Miniature Solution for Real-Time Continuous CO Monitoring

    ENVEA - Model Cairsens CO - Miniature Solution for Real-Time Continuous CO Monitoring

    The Cairsens sensor allows specific pollutant measurement comparable to reference methods. The high quality sensors are renowned worldwide by our customers looking for the newest technologies in air quality monitoring. They offer precise and reliable measurement, and are calibrated using a reference-standard value.  They come with a unique calibration certificate and don’t need any more calibration after installation during their lifetime (12...

  • ENVEA - Model Cairsens NO2 - Miniature Solution for Real-Time Continuous NO2 Monitoring

    ENVEA - Model Cairsens NO2 - Miniature Solution for Real-Time Continuous NO2 Monitoring

    The Cairsens© sensor allows specific pollutant measurement comparable to reference methods. The high quality sensors are renowned worldwide by our customers looking for the newest technologies in air quality monitoring. They offer precise and reliable measurement, and are calibrated using a reference-standard value.  They come with a unique calibration certificate and don’t need any more calibration after installation during their...

  • ENVEA - Model Cairsens O3 / NO2 - Miniature Solution for Real-Time Continuous O3 / NO2 Monitoring

    ENVEA - Model Cairsens O3 / NO2 - Miniature Solution for Real-Time Continuous O3 / NO2 Monitoring

    The Cairsens sensor allows specific pollutant measurement comparable to reference methods. The high quality sensors are renowned worldwide by our customers looking for the newest technologies in air quality monitoring. They offer precise and reliable measurement, and are calibrated using a reference-standard value.  They come with a unique calibration certificate and don’t need any more calibration after installation during their lifetime...

  • ENVEA - Model Cairsens SO2 - Miniature Solution for Real-Time Continuous SO2 Monitoring

    ENVEA - Model Cairsens SO2 - Miniature Solution for Real-Time Continuous SO2 Monitoring

    The Cairsens© sensor allows specific pollutant measurement comparable to reference methods. The high quality sensors are renowned worldwide by our customers looking for the newest technologies in air quality monitoring. They offer precise and reliable measurement, and are calibrated using a reference-standard value.  They come with a unique calibration certificate and don’t need any more calibration after installation during their...

  • ENVEA - Model Cairnet 2020 - Autonomous Networks of Sensor-Based Mini-Stations

    ENVEA - Model Cairnet 2020 - Autonomous Networks of Sensor-Based Mini-Stations

    Cairnet® device is a real-time standalone and networkable air-monitoring station containing up to 6 Cairsens® microsensors and cellular communication within a waterproof enclosure. Thanks to its integrated manifold allowing a dynamic sampling, the measures are accurate and reliable. Electronic compounds are sealed & protected from moisture and corrosive ambient air.

  • Ambient - Gas Generators / Calibrators

  • ENVEA - Model MGC101 - Multi-Gas Calibrator for Ambient Air Gas Analyzers

    ENVEA - Model MGC101 - Multi-Gas Calibrator for Ambient Air Gas Analyzers

    The MGC101 system automatically performs zero, precision, span and multi-point calibrations using NO, NO2, SO2, CO, 03, hydrocarbons and other gases. The MGC101 system automatically performs zero, precision, span and multi-point calibrations using NO, NO2, SO2, CO, 03, hydrocarbons and other gases of interest. It meets all U.S. environmental protection agency requirements.

  • Mercury - Model CalSet - Manual Calibration Set for UT-3000

    Mercury - Model CalSet - Manual Calibration Set for UT-3000

    This accessory meant for manually calibrating the UT-3000 Mercury Ultratracer. The calibration unit is connected to the UT-3000 Ultratracer. With a special syringe a defined volume of mercury containing gas is drawn from the calibrator and injected into the calibration port of the UT-3000. After entering the volume of the injected gas, the UT-3000 will automatically calculate the mercury mass from the volume injected and the calibration cell...

  • ENVEA - Model AutoCal - Automatic Calibration Unit for UT-3000

    ENVEA - Model AutoCal - Automatic Calibration Unit for UT-3000

    This is an accesory for the UT-3000 Mercury Ultratracer in monitoring systems at low to intermediate mercury concentrations. The Mercury Instruments Automatic Calibration Unit consists of a specially designed mercury vessel containing elemental mercury of high purity, surrounded by an aluminium jacket cooled by a thermoelectric cooler. For automatic calibration a motor driven syringe extracts a defined volume of mercury saturated gas and feeds it to...

  • ENVEA - Model MC 3000 - Generation of Mercury Calibration Gas

    ENVEA - Model MC 3000 - Generation of Mercury Calibration Gas

    The MC-3000 generates a continuous stream of a mercury vapor loaded gas in order to check or calibrate mercury analyzers. An exactly adjustable carrier gas stream (normally air or nitrogen) is loaded with mercury in a first step. In a second step the gas is supersaturated by cooling. Subsequently the excess mercury is condensed in a special cell to get exact saturation. The gas is then diluted, the dilution ratio is continuously adjustable in order to...

  • Model NG 3000 - Sample Conditioning System for Natural Gas

    Model NG 3000 - Sample Conditioning System for Natural Gas

    The Natural Gas Sampling System 3000 is designed for very fast conditioning of samples from a pressurized natural gas source. Can be connected directly to a pipeline or a sampling cylinder containing compressed natural gas. The outlet of the sampling system can be connected directly to athe UT-3000 monitor for direct Hg analysis or connected to Tedlar® bags for posterior laboratory analysis.

  • Air Quality Monitoring - Gas Analyzers

    Monitoring the air quality is essential for local authorities as well as for major public and private industries to understand and prevent air pollution and assess emission sources, in order to preserve health and contribute to the fight against the greenhouse effect. Environnement S.A offers advanced environmental monitoring equipment with full turnkey capabilities, that not only delivers accurate real-time data, but also provides long term reliability operating in the

  • Industrial Emission Monitoring - Multi-Gas Monitoring Systems - CEMS

  • ENVEA (ex Environnement S.A) - Model MIR FT - FTIR Multi-Gas Analyzer

    ENVEA (ex Environnement S.A) - Model MIR FT - FTIR Multi-Gas Analyzer

    One single analyzer for the measurement of up to 50 parameters, to be selected according to the application. MCERTs certified. Based on the FTIR technology (Fourier Transform Infrared) for simultaneous measurement of: HCl, HF, NH3, NO, NO2, N2O, SO2, CO, CH4, TOC, H2O, CO2, O2…

  • ENVEA - Model MIR 9000 - Multi-Gas NDIR-GFC Analyzer

    ENVEA - Model MIR 9000 - Multi-Gas NDIR-GFC Analyzer

    Offers excellent performance for multigas measurements in dry sampling, including HCl, HF, NO, NO2, N2O, SO2, CO, CH4, TOC, CO2 and O2 in process applications or for stack emission compliance. Multi-Gas NDIR-GFC analyzer (Non-Dispersive Infrared Gas Filter Correlation) measuring up to ten gases simultaneously, including Nitrogen Oxide (NO), Nitrogen Dioxide (NO2), Sulphur Dioxide (SO2), Carbon Monoxide (CO), even Hydrogen Chloride (HCl) and Hydrogen...

  • ENVEA - Model MIR 9000 CLD - Multi-Gas IR-GFC analyzer

    ENVEA - Model MIR 9000 CLD - Multi-Gas IR-GFC analyzer

    Standard Reference CLD method for low & ultra low NOx measurement, IR-GFC for CO, CO2, SO2, N2O, Nox, HF, HCl, TOC and O2 in a single analyzer. Fast and simultaneous measurements of up to 10 gases, available in 2 versions: NOx (CLD) and O2 (Paramagnetic) in 19’’ Rack or Tight box for low and ultra-low NOx monitoring. CO, CO2, SO2, HCl, HF, TOC, N2O (IR) + NOx (CLD) + O2 (Paramagnetic) in Tight box.

  • Emission Monitoring - Dilution Based Stationary Monitoring Systems

  • ENVEA - Model CO12e Dilution e-Series - Carbon Oxides Analyzer CO - CO2

    ENVEA - Model CO12e Dilution e-Series - Carbon Oxides Analyzer CO - CO2

    Non Dispersive Infra Red Carbon Monoxide Analyzer for CO measurements in the range 0-50ppm. CO2 monitoring as option. The CO12e analyzer is an Eco-designed, reference air quality monitor, QAL1 certified by the TÜV, US-EPA approved and compliant with ISO 4224. It offers superior metrological performances for CO measurements in the range 0-300 ppm. CO2 monitoring as an option (range: 0-2000 ppm by NDIR).

  • ENVEA - Multi-Gas Dilution System

    ENVEA - Multi-Gas Dilution System

    Ideal for mid-high to high concentrations or for sampling locations in hazardous areas. The flue gas is extracted, filtered & diluted with clean / dry air, by an in-stack dilution probe, before being sent to the analyzer. This technique lowers the flue gas dew point, keeping the sample temperature above it and at ambient temperature, in order to eliminate all condensation issues (water interference-free). This also reduces the risk of...