Horizon Technology, Inc.

13 products found

Products

  • By Application - Semi-Volatile

  • SmartPrep - SmartPrep - Automated Cartridge Extraction System

    SmartPrep - SmartPrep - Automated Cartridge Extraction System

    The SmartPrep Cartridge System is designed for simple automation of manual solid phase extraction (SPE) methods. Just like manual SPE, up to 12 samples per SmartPrep System can be run in one batch. To control the SmartPrep System, choose the front touch screen or the intuitive SmartPrep Software. Run the method or different methods for each of the 12 samples.

  • SPE-DEX - Model 4790 - Fully Automated SPE Extraction System

    SPE-DEX - Model 4790 - Fully Automated SPE Extraction System

    The SPE-DEX 4790 Automated Extraction System is a fully automated SPE system designed to rapidly process environmental water samples using solid phase extraction for trace level analysis of organic chemical contaminants. The SPE-DEX 4790 also supports the automation of oil and grease extractions (EPA 1664) globally. Sample volumes ranging from 40 mL up to (8) liters are accommodated.

  • Atlantic - Solid Phase Extraction (SPE) Disks

    Atlantic - Solid Phase Extraction (SPE) Disks

    Horizon Technology 'Certified for Automation', Atlantic SPE Disks are QC tested in our labs to guarantee that you receive the highest quality results when used in conjunction with the Horizon Technology SPE-DEX 4790 Automated Extractor.

  • By Application - Drying & Concentration

  • DryVap - Automated In-Line Drying and Concentration System

    DryVap - Automated In-Line Drying and Concentration System

    The Horizon Technology DryVap Concentrator System automates the drying, evaporation, and concentration of extracts, combining what were once manual steps into one automated process. Unattended operation frees up laboratory personnel for other tasks and eliminates variability between chemists' techniques, producing superior and consistent results. When equipped with the DryDisk Separation Membrane option, the DryVap Concentrator System can dry and...

  • Horizon XcelVap - Automated Concentration and Evaporation System

    Horizon XcelVap - Automated Concentration and Evaporation System

    The XcelVap automated benchtop Evaporation/Concentration System is a modern compact benchtop lab product that provides rapid, gentle evaporation of up to 54 sample extracts, ranging in size from less than 1 mL up to 200 mL. Laboratories in all industries routinely evaporate/concentrate sample extracts to provide the best analytical sensitivity in the chromatography step say Bob Johnson, CTO and Founder. The XcelVap provides a number of features such...

  • DryDisk - Solid Phase Extraction (SPE) Disks & Barrels for Separation Membrane

    DryDisk - Solid Phase Extraction (SPE) Disks & Barrels for Separation Membrane

    DryDisk Separation Membranes offer a much more efficient means of drying solvents in organic extractions than sodium sulfate. Because it is a physical separation rather than a chemical process to remove residual water from organic solvent extracts, DryDisk Separation Membranes eliminate the problems inherent with chemical drying such as retention of water-soluble compounds, over-saturation, clogging, oven drying, messy waste removal, and...

  • Horizon - Model SDS-101 - Solvent Drying System

    Horizon - Model SDS-101 - Solvent Drying System

    The SDS-101 Solvent Drying System simplifies and speeds up the solvent drying step in sample preparation. The system consists of the DryDisk Separation Membrane, PTFE Membrane Holder Assembly, precision controlled Vacuum Regulator, and Docking Bracket Assembly.

  • Reclaimer - Solvent Recovery System (SRS)

    Reclaimer - Solvent Recovery System (SRS)

    The Horizon Technology Reclaimer Solvent Recovery System (SRS) is designed to condense and collect solvent vapors which are generated by Horizon Technology's DryVap Concentrator System. Using a vacuum pump, the solvent vapors are pulled through a cold condenser coil, where the solvent vapors are chilled and converted back into a liquid form. The solvent then flows by vacuum and gravity into a plastic solvent resistant collection bottle. Once the...

  • Others

  • Solvent Trap - Automated Solvent Recovery System

    Solvent Trap - Automated Solvent Recovery System

    For the efficient automation of Oil and grease extraction, EPA Method 1664,  Horizon’s Solvent Trap attaches quickly and easily to the exhaust hose from the SpeedVap III Solvent evaporation system. Place the 500mL glass Erlenmyer collection vessel (provided) in the collection chamber and turn the system ‘ON’ to begin condensing Hexane vapors.

  • By Application - Oil and Grease

  • SPE-DEX - Model 3000XL - Oil & Grease Automated Extraction System

    SPE-DEX - Model 3000XL - Oil & Grease Automated Extraction System

    The SPE-DEX 3000XL Extractor automates EPA Method 1664A, and provides an alternative to expensive, labor-intensive LLE methods for extracting oil and grease from aqueous samples. Using a combination of advanced liquid handling and 'Certified for Automation' Pacific O&G SPE...

  • SPE-DEX - Model 1000XL - Fully Automated, Single-Station Oil & Grease Extraction System

    SPE-DEX - Model 1000XL - Fully Automated, Single-Station Oil & Grease Extraction System

    A fully automated, single-station extraction system, the Horizon Technology SPE-DEX 1000XL Automated Extractor System provides maximum speed, accuracy and simplicity for extracting a wide range of 'clean' and 'dirty' aqueous samples for oil and grease and non-polar material (NPM) by EPA Method 1664A & 1664B. The SPE-DEX1000XL is ideal for facilities that process only a few samples each...

  • Pacific - Oil and Grease Spe Disks

    Pacific - Oil and Grease Spe Disks

    The economical choice for quality results at the lowest cost. Method 1664 is a performance-based method that requires the use of n-hexane as the extraction solvent and gravimetry as the determinative technique. Alternative extraction and concentration techniques are allowed, provided that the performance specifications are met. In addition, QC procedures designed to monitor precision and accuracy have been incorporated into Method 1664A.