HyXo OY

HyXo OY

50 products found

Products by STS Sensor Technik Sirnach AG

  • Piezoresistive OEM Measuring Cell

  • Pressure and Temperature Transmitters

  • Pressure Switch

  • STS - Piezoresistive Transducer

    STS - Piezoresistive Transducer

    Pressure measuring range: 100 mbar … 1000 bar. Accuracy: ≤ ± 0.50 / 0.25 % FS. Output signal: mV. Materials: Stainless steel, Titanium, Hastelloy.

  • STS - Model ATM/T - Analog Transmitter

    STS - Model ATM/T - Analog Transmitter

    Pressure measuring range: 100 mbar…1000 bar. Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS. Temperature measuring range: -50…150 °C. Operating temperature: -25…85 °C. Process temperature: -40…150 °C. 2 Output signals (p & T): 0…10 V DC, 0…20 / 4…20 mA. Materials: Stainless steel, Titanium.

  • STS - Model ATM/GR - Pressure Switch

    STS - Model ATM/GR - Pressure Switch

    Pressure measuring range: 100 mbar … 1000 bar. Two potential free switches (48 V, 2 A, 60W). Operating temperature: -25 … 85°C. Process temperature: -40 … 150°C. Materials: Stainless steel, Titanium. Output signal 0 … 20 mA / 4 … 20 mA.

  • Liquid Level Transmitter - Miniature Submersible Level Transmitters

  • Pressure Transmitter - Intrinsically Safe Pressure Transmitter - FM/FMc Certified

  • STS - Model ATM/IS - Analog Pressure Transmitter

    STS - Model ATM/IS - Analog Pressure Transmitter

    Pressure measuring range: 100 mbar … 690 bar. Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS. Operating temperature: -25 … 85°C. Process temperature: -40 … 150°C. Output signal: 4 … 20 mA. Materials: Stainless steel, Titanium.

  • STS - Model ATM.1ST/IS - High Precision Transmitter

    STS - Model ATM.1ST/IS - High Precision Transmitter

    Pressure measuring range: 100 mbar … 690 bar. Accuracy: ≤ ± 0.10 / 0.05 % FS. Operating temperature: -40 … 125°C. Process temperature: -40 … 150°C. Output signal: 4 … 20 mA. Total Error Band: ≤ ± 0.30 %FS (0…70 °C). Materials: Stainless steel, Titanium.

  • STS - Model ATM/F/IS - Hygienic Pressure Transmitter

    STS - Model ATM/F/IS - Hygienic Pressure Transmitter

    Pressure measuring range: 100 mbar … 25 bar. Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS. Operating temperature: -25 … 85°C. Process temperature: -25 … 100°C. Output signal: 4 … 20 mA. Materials: Stainless steel.

  • STS - Model MTM/N 10 - Miniature Level Transmitter

    STS - Model MTM/N 10 - Miniature Level Transmitter

    Pressure measuring range: 10…100 mH2O. Accuracy: ≤ ± 0.50 / 0.25. Operating temperature: -5…50 °C. Process temperature: -5…50 °C. Output signal: mV / 4...20 mA / 0...10 VDC. Materials: Stainless steel, Titanium. 10 mm outside diameter.

  • STS - Model ATM/N 19 - Miniature Level Transmitter

    STS - Model ATM/N 19 - Miniature Level Transmitter

    Pressure measuring range: 1…250 mH2O. Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS. Operating temperature: -5…80 °C. Process temperature: -5…80 °C. Output signal: 0 … 5 / 0 … 10 VDC, 4 … 20 mA. Materials: Stainless steel. 19 mm outside diameter.

  • Pressure Transmitter - Pressure Transmitter 4-20mA / 0-10V

  • STS - Model ATM.mini - Miniature Transmitter

    STS - Model ATM.mini - Miniature Transmitter

    Pressure measuring range: -1 bar … 100 bar. Accuracy: ≤ ± 0.2 / 0.1 % FS. Operating temperature: -40 … 125°C. Process temperature: -40 … 125°C. Output signal: 0.5 … 4.5 VDC / 4 …. 20 mA. Total Error Band: ≤ ± 0.5 %FS. Process connection: 1/8 NPT M, 3/8 - 24 UNJF, M8 x 1 M, M10 x 1 M. Materials: Stainless steel.

  • STS - Model ATM - Analog Pressure Transmitter

    STS - Model ATM - Analog Pressure Transmitter

    Pressure measuring range: 100 mbar … 1000 bar. Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS. Operating temperature: -25 … 85°C. Process temperature: -40 … 150°C. Output signal: 0 … 5 / 0 … 10 VDC, 0 … 20 / 4 … 20 mA. Process connection: G 1/4 F, 1/4 NPT, 1/2 NPT, G 1/4 M, G1/2 M. Materials: Stainless steel, Titanium.

  • STS - Model ATM.ECO - Analog Pressure Transmitter with Temperature Compensation

    STS - Model ATM.ECO - Analog Pressure Transmitter with Temperature Compensation

    Pressure measuring range: 100 mbar … 1000 bar. Accuracy: ≤ ± 0.2 % FS. Operating temperature: -40 … 125°C. Process temperature: -40 … 150°C. Output signal: 0 … 5 / 0 … 10 VDC, 4 … 20 mA. Total Error Band: ≤ ± 0.30 %FS (0 … 70°C). Process connection: G 1/4 F, 1/4 NPT, 1/2 NPT, G 1/4 M, G1/2 M. Materials: Stainless steel.

  • Pressure Transmitter - Intrinsically Safe Pressure Transmitters - ATEX / IECEx Certified

  • Liquid Level Transmitter - Level Transmitters 4-20mA / 0-10V

  • STS - Model ATM/Ex - Analog Pressure Transmitter

    STS - Model ATM/Ex - Analog Pressure Transmitter

    Pressure measuring range: 100 mbar … 1000 bar. Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS. Operating temperature: -25 … 85°C. Process temperature: -40 … 150°C. Output signal: 4 … 20 mA. Materials: Stainless steel, Titanium.

  • STS - Model ATM.1ST/Ex - High Precision Transmitter

    STS - Model ATM.1ST/Ex - High Precision Transmitter

    ATM.1ST/Ex - High Precision Transmitter. Pressure measuring range: 100 mbar … 1000 bar. Accuracy: ≤ ± 0.10 / 0.05 % FS. Operating temperature: -40 … 125°C. Process temperature: -40 … 150°C. Output signal: 4 … 20 mA. Total Error Band: ≤ ± 0.30 %FS (0…70 °C). Materials: Stainless steel, Titanium.

  • STS - Model ATM/F/Ex - Hygienic Pressure Transmitter

    STS - Model ATM/F/Ex - Hygienic Pressure Transmitter

    Pressure measuring range: 100 mbar … 25 bar. Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS. Operating temperature: -25 … 85°C. Process temperature: -25 … 100°C. Output signal: 4 … 20 mA. Materials: Stainless steel.

  • STS - Model TM/Ex - Passive Transmitter

    STS - Model TM/Ex - Passive Transmitter

    Pressure measuring range: 100 mbar … 1000 bar. Accuracy: ≤ ± 0.50 / 0.25 % FS. Operating temperature: -40 … 125°C. Process temperature: -40 …  50°C. Outp t signal: mV. Materials: Stainless steel, Titanium.

  • STS - Model PTM/Ex - Programmable Transmitter

    STS - Model PTM/Ex - Programmable Transmitter

    Pressure measuring range: 100 mbar … 1000 bar. Adjustable 1:4 of the nominal range within -5% to +105%. Accuracy: ≤ ± 0.25 / 0.10 % FS. Operating temperature: -25 … 85°C. Process temperature: -40 … 150°C. Output signal: 4 … 20 mA.  aterials: Stainless steel, Titanium.

  • STS - Model ATM/N - Analog Level Transmitter

    STS - Model ATM/N - Analog Level Transmitter

    Pressure measuring range: 1 … 250 mH2O. Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS. Operating temperature: -5 … 80°C. Process temperature: -5 … 80°C. Output signal: 0 … 5 / 0 … 10 VDC, 0 … 20 / 4 … 20 mA. Materials: Stainless steel, Titanium. Cable: PUR, PE, PTFE, connactable.

  • Liquid Level Transmitter - Chemical Resistant Submersible Level Transmitters

  • Liquid Level Transmitter - High Precision Level Transmitters 4-20mA / 0-10V

  • Pressure Transmitter - High Precision Pressure Transmitter 4-20mA / 0-10V

  • STS - Model ATM.1ST/N - High Precision Level Transmitter

    STS - Model ATM.1ST/N - High Precision Level Transmitter

    Pressure measuring range: 1 … 250 mH2O. Accuracy: ≤ ± 0.10 % FS. Total Error Band: ≤ ± 0.30 %FS (-5 … 50°C). Operating temperature: -5 … 80°C. Process temperature: -5 … 80°C. Output signal: 0 … 5 / 0 … 10 VDC, 4 … 20 mA. Materials: Stainless steel, Titanium.

  • STS - Model ATM.1ST/N/T - High Precision Level Transmitte

    STS - Model ATM.1ST/N/T - High Precision Level Transmitte

    Pressure measuring range: 1 … 250 mH2O. Accuracy: ≤ ± 0.10 % FS. Total Error Band: ≤ ± 0.30 %FS (-5 … 50°C). Operating temperature: -5 … 80°C. Process temperature: -5 … 80°C. 2 Output signals (p & T): 0 … 5 / 0 … 10 VDC, 4 … 20 mA. Materials: Stainless steel, Titanium.

  • STS - Model ATM.1ST - High Precision Transmitter

    STS - Model ATM.1ST - High Precision Transmitter

    Pressure measuring range: 100 mbar … 1000 bar. Accuracy: ≤ ± 0.10 / 0.05 % FS. Operating temperature: -40 … 125°C. Process temperature: -40 … 150°C. Output signal: 0 … 5 / 0 … 10 VDC, 4 … 20 mA. Total Error Band: ≤ ± 0.30 %FS (0 … 70°C). Process connection: G 1/4 F, 1/4 NPT, 1/2 NPT, G 1/4 M, G1/2 M. Materials: Stainless steel, Titanium.

  • Liquid Level Transmitter - Intrinsically Safe Submersible Level Transmitters - FM/FMc Certified

  • Pressure Transmitter - Fieldbus & Digital Pressure Transmitter

  • STS - Model DTM.OCS.S - Modbus Transmitter

    STS - Model DTM.OCS.S - Modbus Transmitter

    Pressure measuring range: 200 mbar…100 bar. Accuracy: ≤ ± 0.15 / 0.05 / 0.03 % FS. Operating temperature: -40…85 °C. Process temperature: -40…85 °C. Interface: RS485. Materials: Stainless steel, Titanium.

  • STS - Model PTM/RS485 - Fieldbus & Digital Pressure Transmitter

    STS - Model PTM/RS485 - Fieldbus & Digital Pressure Transmitter

    Pressure measuring range: 100 mbar … 1000 bar. Adjustable 1:4 of the nominal range within -5% to +105% (analog output). Accuracy: ≤ ± 0.25 / 0.10 % FS. Temperature measuring range: -25 … 85°C. Operating temperature: -25 … 85°C. Process temperature: -40 … 150°C. 2 Output signals (p & T): 4 … 20 mA. Interface: RS485. Materials: Stainless steel, Titanium.

  • STS - Model ATM/N/IS - Analog Level Transmitter

    STS - Model ATM/N/IS - Analog Level Transmitter

    Pressure measuring range: 1 … 250 mH2O. Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS. Operating temperature: -5 … 80°C. Process temperature: -5 … 80°C. Output signal: 4 … 20 mA. Materials: Stainless steel, Titanium.

  • Pressure Transmitter - Programmable Pressure Transmitter

  • Liquid Level Transmitter - Intrinsically Safe Submersible Level Transmitters - ATEX / IECEx Certified

  • STS - Model PTM - Pressure Transmitter 4-20mA

    STS - Model PTM - Pressure Transmitter 4-20mA

    Pressure measuring range: 100 mbar…1000 bar. Adjustable: 1:4 of the nominal range within -5% to +105%. Accuracy: ≤ ± 0.25 / 0.10 % FS. Operating temperature: -25…85 °C. Process temperature: -40…150 °C. Output signal: 4…20 mA. Materials: Stainless steel, Titanium.

  • STS - Model TM/N/Ex - Passive Level Transmitter

    STS - Model TM/N/Ex - Passive Level Transmitter

    Pressure measuring range: 1…250 mH2O. Accuracy: ≤ ± 0.50 / 0.25 % FS. Operating temperature: -5…80 °C. Process temperature: -5…80 °C. Output signal: mV. Materials: Stainless steel, Titanium.

  • STS - Model ATM/N/Ex - Analog Level Transmitter

    STS - Model ATM/N/Ex - Analog Level Transmitter

    Pressure measuring range: 1 … 250 mH2O. Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS. Operating temperature: -5 … 80°C. Process temperature: -5 … 80°C. Output signal: 4 … 20 mA. Materials: Stainless steel, Titanium. Feature: Optional overvoltage protection.

  • Liquid Level Transmitter - Passive (mV) Submersible Level Transmitters

  • Pressure Transmitter - Passive Transmitter (mV)

  • STS - Model TM - Passive Transmitter

    STS - Model TM - Passive Transmitter

    Pressure measuring range: 100 mbar … 1000 bar. Accuracy: ≤ ± 0.50 / 0.25 % FS. Operating temperature: -40 … 125°C. Process temperature: -40 … 150°C. Output signal: mV. Materials: Stainless steel, Titanium.

  • STS - Model TM/N - Passive Level Transmitter

    STS - Model TM/N - Passive Level Transmitter

    Pressure measuring range: 1…250 mH2O. Accuracy: ≤ ± 0.50 / 0.25 % FS. Operating temperature: -5…80 °C. Process temperature: -5…80 °C. Output signal: mV. Materials: Stainless steel, Titanium.

  • STS - Model TM/N/Ex - Passive Level Transmitter

    STS - Model TM/N/Ex - Passive Level Transmitter

    Pressure measuring range: 1…250 mH2O. Accuracy: ≤ ± 0.50 / 0.25 % FS. Operating temperature: -5…80 °C. Process temperature: -5…80 °C. Output signal: mV. Materials: Stainless steel, Titanium.

  • Pressure Transmitter - Hygienic Pressure Transmitter

  • Liquid Level Transmitter - Programmable Level Transmitter

  • STS - Model ATM/F - Hygienic Pressure Transmitter

    STS - Model ATM/F - Hygienic Pressure Transmitter

    Pressure measuring range: 100 mbar … 25 bar. Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS. Operating temperature: -25 … 85°C. Process temperature: -25 … 100°C. Output signal: 0 … 5 / 0 … 10 VDC, 0 … 20 / 4 … 20 mA. Materials: Stainless steel.

  • STS - Model PTM/N - Programmable Level Transmitter

    STS - Model PTM/N - Programmable Level Transmitter

    Pressure measuring range: 1…250 mH2O. Accuracy: ≤ ± 0.25 / 0.10 % FS. Adjustable 1:4 of the nominal range within -5% to +105%. Operating temperature: -5…80 °C. Process temperature: -5…80 °C. Output signal: 4…20 mA. Materials: Stainless steel, Titanium. Feature: Recalibration with software possible.

  • STS- - Model PTM/N/RS485 - Programmable Level Transmitter

    STS- - Model PTM/N/RS485 - Programmable Level Transmitter

    Pressure measuring range: 1…250 mH2O. Adjustable 1:4 of the nominal range within -5% to +105% (analog output). Accuracy: ≤ ± 0.25 / 0.10 % FS. Temperature measuring range: -25…85 °C. Operating temperature: -5…80 °C. Process temperature: -5…80 °C. 2 Output signals (p & T): 4…20 mA. Interface: RS485 (Modbus RTU). Materials: Stainless steel, Titanium. Feature: Recalibration with software...

  • STS - Model PTM/N/SDI-12 - Programmable Level Transmitter

    STS - Model PTM/N/SDI-12 - Programmable Level Transmitter

    Pressure measuring range: 5…250 mH2O. Accuracy: ≤ ± 0.25 / 0.10 % FS. Temperature measuring range: -25…85 °C. Operating temperature: -5…50 °C. Process temperature: -5…50 °C. Interface: SDI-12 (V1.3). Materials: Stainless steel, Titanium. Feature: Recalibration possible, Adjustable units.

  • STS - Model PTM/N/Ex - Programmable Level Transmitter - 4-20mA

    STS - Model PTM/N/Ex - Programmable Level Transmitter - 4-20mA

    Pressure measuring range: 1…250 mH2O. Accuracy: ≤ ± 0.25 / 0.10 % FS. Adjustable 1:4 of the nominal range within -5% to +105%. Operating temperature: -5…80 °C. Process temperature: -5…80 °C. Output signal: 4…20 mA. Materials: Stainless steel, Titanium.

  • Liquid Level Transmitter - Fieldbus Level Transmitters

  • Temperature Transmitter

  • STS - Model DTM.OCS.S/N - Modbus Level Transmitter

    STS - Model DTM.OCS.S/N - Modbus Level Transmitter

    Pressure measuring range: 1 … 250 mH2O. Accuracy: ≤ ± 0.15 / 0.05 / 0.03 % FS. Operating temperature: -5 … 80 °C. Process temperature: -5 … 80 °C. Interface: RS485. Materials: Stainless steel, Titanium.

  • STS - Model TS 100 - Temperature Transmitter

    STS - Model TS 100 - Temperature Transmitter

    Temperature measuring range: -50 … 150°C. Operating temperature: -25 … 85°C. Process temperature: -50 … 150°C. Output signal: 0 … 5 / 0 … 10 VDC, 0 … 20 / 4 … 20 mA. Materials: Stainless steel. 850 bar compression proofed.

  • Level and Temperature Transmitter

  • STS - Model ATM/N/T - Analog Transmitter

    STS - Model ATM/N/T - Analog Transmitter

    Pressure measuring range: 1 … 250 mH2O. Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS. Temperature measuring range: -5 … 80°C. Operating temperature: -5 … 80°C. Process temperature: -5 … 80°C. 2 Output signals (p & T): 0 … 10 VDC, 0 … 20 / 4 … 20 mA. Materials: Stainless steel, Titanium.

  • Hydrostatic Level Logger and Water Management

  • STS - Model DL.OCS/N/RS485 - Level Logger

    STS - Model DL.OCS/N/RS485 - Level Logger

    Pressure measuring range: 0 … 250 mH2O. Total Error: ≤ ± 0.05 % FS (-5 ... 50°C). Temperature measuring range: -5 … 80°C. Operating temperature: -5 … 80°C. Process temperature: -5 … 80°C. Interface: RS485. Materials: Stainless steel, titanium. Battery operation, Measurement interval 1s … 24h, 1.5 Mio. Measurement values.

  • STS - Model DL.WMS/GPRS/R/SDI-12 - Water Manager

    STS - Model DL.WMS/GPRS/R/SDI-12 - Water Manager

    Pressure measuring range: 5 … 250 mH2O. Accuracy: ≤ ± 0.10 % FS. Temperature measuring range: -5 … 80°C. Operating temperature: -5 ... 80 / -5 ... 50 °C (logger). Process temperature: -5 … 80°C. Radio interface: 433 MHz. Data transfer: GSM/GPRS. Frequency band: 850/900, 1800/1900 MHz (Quadband). Materials level transmitter: Stainless steel, Titanium. Materials logger: Plastic, Stainless steel. Feature:...