10 products found
JCT Analysentechnik GmbH Products
-
Gas Sampling Probes
-
JCT - Model JES-301LM - Gas Sampling Probe for Marine
Applications: Marine applications compliant to MARPOL standards. Representative continuous gas sampling in processes containing dust and humidity. Extractive gas analysis. Emission (CEMS) and process monitoring. Removal of dust from the sample ...
-
JCT - Model JES-360H - Gas Sampling Probe 315°C for Pre-Filter Back Flush
Applications: Representative continuous gas sampling in processes containing high dust and humidity. Extractive gas analysis. Emission (CEMS) and process monitoring. Removal of dust from the sample ...
-
JCT - Model JES-360Ex - Gas Sampling Probe for Pre-Filter Back Flush
Applications: Representative continuous gas sampling in processes containing high dust and humidity. Installation in Ex-zone 1, 2 or 21, 22. Hazardous gases. Pressurized processes. Extractive gas analysis. Emission (CEMS) and process monitoring. Removal of dust from the sample ...
-
JCT - Model JES-370 - Gas Sampling Probe DeNOx
Applications: For extractive gas analysis. For continuous gas sampling e.g. downstream DENOx plants (SCR). For removal of dust and other interfering solids e.g. ammonia salts from the sample gas flow. For outdoor and indoor ...
-
JCT - Model JES-380 - Gas Sampling Probe for Sample Gas Dilution (Preliminary)
Applications: Representative continuous gas sampling in processes containing high dust and humidity. Extractive gas analysis. Emission (CEMS) and process monitoring. Removal of dust from the sample gas. Dilution of sample ...
-
JCT - Model JER - Sampling Pipes and JHD Pre-Filters
Applications: For extractive gas analysis. For emission and process monitoring. For gas sampling at corrosive process gases. For gas sampling at process temperatures up to 1800 °C. For gas sampling at high dust concentrations > 2 g/m3. For adaption to all stationary JCT gas sampling ...
-
JCT - Model JER-EH - Heated Sampling Pipe
Applications: For extractive gas analysis. For emission and process monitoring. For avoidance of acid dew point lower deviaton between sampling point and gas sampling probe. Combinable with gas sampling probes JES-301 and ...
-
JCT - Model JHPF - Heated Adapter Pipe
Applications: For extractive gas analysis. For emission and process monitoring. Process external heating of pre-filters for applications with high dust concentrations combined with high process temperatures (above maximum temperature of pre-filter). Combinable with gas sampling probes JES-301 and ...
-
JCT - Model JES-301K - Back Purge Control Unit
Applications: For extractive gas analysis. For emission and process monitoring. For control of automatic back purge of JCT gas sampling probes series JES-301. For applications with high dust concentrations. For regular cleaning of probe filter, filter chamber and possible ...
-
JCT - Model JES-301KE1 - Back Purge Control Unit for Ex-Zone 1
Applications: For extractive gas analysis. For emission and process monitoring in Ex-area zone 1. For control of automatic back purge of explosion proof JCT gas sample probes series JES-301. For applications with high dust concentrations. For regular cleaning of probe filter, filter chamber and possible ...