Ocean Optics  - a Halma Company

15 products found

Products

  • Probes

  • QF600-8-VIS/NIR Fiber Fluorescence Probe

    QF600-8-VIS/NIR Fiber Fluorescence Probe

    The QF600-8-VIS/NIR Fiber Optic Fluorescence Probe has a unique optical design that allows users to control the depth of sampling and to optimize the region of overlap between excitation and emission fibers. The probe uses 1 flat fiber for detection and 7 angled fibers that direct excitation energy to the region in front of the detection fiber. An adjustable window facilitates choosing the depth of overlap.

  • T300-RT and T200-RT General Purpose Transmission Dip Probes

    T300-RT and T200-RT General Purpose Transmission Dip Probes

    Our T300-RT and T200-RT Transmission Dip Probes couple to our spectrometers and light sources to measure absorbance and transmission in solutions. These probes are especially useful for embedding into process streams for in situ, real-time sample monitoring.

  • TP300 Transmission Dip Probes For Hostile Environments

    TP300 Transmission Dip Probes For Hostile Environments

    The TP300-UV-VIS Transmission Dip Probe couples to our spectrometers and light sources to measure the absorbance and transmission of solutions in harsh environments. The TP300-UV-VIS Probe is a chemically inert PEEK transmission probe that can be equipped with a tip (RT-PH) for mounting transmissive films in the optical path. Light is directed via one fiber through the mounted film to a mirror. Then light is redirected back through the film to a receive...

  • TI300 Industrial Transmission Dip Probes

    TI300 Industrial Transmission Dip Probes

    Our TI300-series Transmission Industrial Dip Probes can be used in environments with pressure limits up to 250 psi and at temperatures up to 300 °C. The TI300-UV-VIS uses 300 µm diameter solarization-resistant optical fiber (200-1100 nm), while the TI300-VIS-NIR uses 300 µm diameter VIS-NIR optical fiber (400-2200 nm). The TI300 probes couple to our spectrometers and light sources to measure solutions absorbance and transmission in industrial applications.

  • Reflection/Backscattering Probes With Reference Leg

    Reflection/Backscattering Probes With Reference Leg

    Our Fiber Optic Reflection / Backscattering Probes are used for measuring specular or diffuse reflectance from a surface, fluorescence from solid surfaces, or backscattering and fluorescence in solutions and powders. We offer several Reflection / Backscattering Probes that include a reference leg for monitoring the illumination (or reference) source, which is useful for any experiment in which variation or instability in the spectral output of the light...

  • Reflection/Backscattering Probes With Expanded Wavelength Coverage

    Reflection/Backscattering Probes With Expanded Wavelength Coverage

    R-series Fiber Optic Reflection Probes couple to our spectrometers and light sources to create small-footprint optical-sensing systems for measuring reflection and fluorescence from solid surfaces, or backscattering and fluorescence in liquids and powders. Reflection probes can be optimized for the UV/VIS (250-800 nm) or VIS/NIR (400-2100 nm), or a combination of both ranges.

  • Reflection/Backscattering Angled Probes For Solution & Powders

    Reflection/Backscattering Angled Probes For Solution & Powders

    Fiber Optic Reflection / Backscattering Probes couple to our spectrometers and light sources to create small-footprint optical-sensing systems for measuring reflection and fluorescence in liquids and powders. Our angled probes also have a six-around-one design, but employ a 30° window to remove specular reflection effects when the probe is immersed in powders or dense solutions. We offer the angled probe with two different diameter fibers, 200 µm and 400...

  • Attenuated Total Reflection Probe

    Attenuated Total Reflection Probe

    The PRO-PROBE-ATR Probe is a Attenuated Total Reflection Probe designed for measuring highly absorbent samples. The ATR Probe is ideal for applications where the absorbance of samples is in the 4000-5000 AU/cm range. The ATR Probe can be inserted directly into the sample and spectra can be taken without sample dilution. Typical applications involve measurement of pure inks, dyes and crude oil samples. What's more, the ATR Probe can be used as a general...

  • Double-Pass Transmission Probe

    Double-Pass Transmission Probe

    The process-ready Double-Pass Transmission Probe is useful for online measurement of sample streams in demanding environments. The probes is available in various pathlengths and materials, have linearity superior to that of transflection probes, and can be used as part of a process system or combined with Ocean Optics spectrometers and accessories to create real-time monitoring systems for a variety of transmission applications.

  • Single-pass Transmission Probe

    Single-pass Transmission Probe

    The Process-ready Single-Pass Transmission Probe from Custom Sensors & Technology is useful for online measurements of sample streams in demanding environments. Probes are available in various pathlengths and materials, have linearity superior to that of transflection probes, and can be used as part of a process system or combined with Ocean Optics spectrometers and accessories to create real-time monitoring systems for a variety of transmission...

  • Fluorescence/Backscattering Probe

    Fluorescence/Backscattering Probe

    The Front-surface Fluorescence Probe is a process-ready probe for measuring fluorescence from the surface of a liquid, solid, paste or slurry. The probes can be used as part of a process system or combined with Ocean Optics spectrometers and accessories to create a real-time monitoring system for a variety of fluorescence applications.

  • Fiber Optic Oxygen Sensor Probe Options

    Fiber Optic Oxygen Sensor Probe Options

    Fiber Optic Oxygen Sensors are spectrometer-coupled chemical sensors for full spectral analysis of dissolved and gaseous oxygen pressure. Fiber Optic Oxygen Sensors are designed for use with our modular components. First select a Sensor Coating Formulation. Then select a Fiber Optic Probe onto which the sensor coating will be applied. You select these items to create complete systems. All system components are priced separately.

  • Oxygen Sensor Care & Compatibility

    Oxygen Sensor Care & Compatibility

    Your Oxygen Sensor probe is very easy to maintain. It can be left in air indefinitely, but don't leave it exposed to your excitation light source when it is not in use. Dropping the probe could cause the optical fiber to break. Be sure not to over tighten the SMA connections. Clean your probes with 10% hypochlorite detergent and sterilize them with Gamma radiation or sodium hypochlorite (bleach). See below for further details on cleaning and...

  • Single-Point Reflection Stage

    Single-Point Reflection Stage

    The Single-point Reflection Stage is a probe holder for reflection measurements of optical layers and other substrates up to 150 mm in diameter. The Single-point Reflection Stage is a probe holder for reflection measurements of optical layers and other substrates up to 150 mm in diameter. The probe holder accommodates fiber optic probes and other sampling devices up to 6.35 mm in diameter, and slides up and down a stainless steel post for adjustment to...

  • Reflection and Transmission Stage

    Reflection and Transmission Stage

    The Stage-RTL-T is a novel sampling system for analysis of substrate materials such as silicon, metals, glass and plastics. The RTL-T couples to our spectrometers and light sources, and can be configured in a variety of setups, for reflection and transmission measurements. Available for $2715, the Stage-RTL-T consists of a variable rail attached to a base plate, with three devices that attach to the rail with a thumbscrew. From bottom to top, these...