Phenomenex, Inc.

61 products found

Phenomenex, Inc. Products

  • Zebron GC Products

  • Zebron - Model ZB-1 - GC Columns

    Zebron - Model ZB-1 - GC Columns

    Low Polarity for a Wide Range of Applications; Rugged, high efficiency, and MS Certified low bleed. Well-suited for true boiling point separations. Excellent resolving power of critical pairs in complex petrochemical samples. Used for “fingerprinting” and routine quality control analyses (e.g., citrus oils).

  • Zebron - Model ZB-5 - GC Columns

    Zebron - Model ZB-5 - GC Columns

    Low Polarity for a Wide Range of Separations; Versatile column recommended for a wide range of applications. Great column for unknown samples. Resilient to dirty samples – long column life.

  • Zebron - Model ZB-35 - Fused Silica GC Column

    Zebron - Model ZB-35 - Fused Silica GC Column

    Low Bleed, Intermediate Polarity Selectivity for GC/MS; Intermediate polarity column for high molecular weight analysis. Inert to minimize analyte adsorption, improve efficiency, and reproducibility. More rugged (longer column life) than other polar phases. Excellent for trace analysis with bleed-sensitive detectors (MS, FID, ECD, NPD).

  • Zebron - Model ZB-50 - Fused Silica GC Column

    Zebron - Model ZB-50 - Fused Silica GC Column

    Rugged Performance for High Polarity Selectivity; High polarity column capable of high temperature bakeout to remove contaminants. Inert to minimize analyte adsorption, improve efficiency, and reproducibility. More rugged (longer column life) than other polar phases. Great for toxicology and environmental compounds.

  • Zebron - Model ZB-1701 - GC Columns

    Zebron - Model ZB-1701 - GC Columns

    Alternate Selectivity for Mid-Polarity Analyses; Fast run and re-equilibration times for enhanced sample throughput and productivity. Provides alternate selectivity to phenyl phases with similar polarity.

  • Zebron - Model ZB-1MS - Fused Silica GC Column

    Zebron - Model ZB-1MS - Fused Silica GC Column

    Low Bleed Performance for GC/MS: Very low bleed (MS Certified) especially suited to high sensitivity GC/MS. Improved signal-to-noise ratio for better sensitivity and mass spectral integrity. Extremely inert for active compounds such as drugs, pesticides, acids, and bases.

  • Zebron - Model ZB-1HT Inferno - High Temperature Fused Silica GC Column

    Zebron - Model ZB-1HT Inferno - High Temperature Fused Silica GC Column

    Inferno: Rugged Performance Up to 430 °C: Rugged, high temperature stable (430 °C), polyimide-coated fused silica phase. Robust column performance for high temperature bake outs. True boiling point separation for hydrocarbon distillation methods. Recommended for chemists struggling with high boilers, contaminants, or carry-overs.

  • Zebron - Model ZB-1XT SimDist - Metal Column

    Zebron - Model ZB-1XT SimDist - Metal Column

    New Glass Infusion technology provides higher efficiency and greater column-to-column reproducibility. Increased accuracy for high temperature simulated distillation analysis. Up to 70 % more efficiency than other columns. Improved resolution of C50/C52.

  • Zebron - Model ZB-5MS - Fused Silica GC Column

    Zebron - Model ZB-5MS - Fused Silica GC Column

    Low Bleed Performance for GC/MS; Most popular starting column for method developers. Arylene Matrix Technology (AMT) provides a highly stable arylene phase for enhanced resolution of PAHs and multi-ring aromatic compounds. Low bleed (MS certified) especially suited to high sensitivity work using GC/MS.

  • Zebron - Model ZB-5MSi - Fused Silica GC Column

    Zebron - Model ZB-5MSi - Fused Silica GC Column

    Highly inert for improved peak shape of acidic/basic compounds, drugs of abuse, and pesticides. MS certified low bleed levels provide maximum sensitivity. Industry leading QC specifications ensure column-to-column performance. Traditional bonding chemistry provides the same selectivity as the ZB-5 columns.

  • Zebron - Model ZB-XLB - Fused Silica GC Column

    Zebron - Model ZB-XLB - Fused Silica GC Column

    Unique low polarity si-arylene column for MS detectors. Provides alternative selectivity to standard 5-type phases. Often used for confirmation of pesticide, PCB, or other environmental sample. Good tool for sample screening to identify unknown contaminants.

  • Zebron - Model ZB-MultiResidue-1 - Fused Silica GC Column

    Zebron - Model ZB-MultiResidue-1 - Fused Silica GC Column

    Specially designed for the separation of all types of pesticides, herbicides, and insecticides. Well-suited for dual column analysis with Zebron ZB-MultiResidue™-2. Performance exceeds US EPA Method 8081A specifications for chlorinated pesticides.   Low activity, decreased breakdown of sensitive pesticides such as DDT. MS Certified phases provide low bleed performance for pesticide confirmation by...

  • Zebron - Model ZB-624 - Fused Silica GC Column

    Zebron - Model ZB-624 - Fused Silica GC Column

    Popular choice for residual solvent testing (USP Monograph). Widely used to separate volatile organic flavor and fragrance additives and residual solvents in industrial or pharmaceutical products (OVIs). Increased temperature limit speeds run times and re-equilibration. Formulated for low bleed.

  • Zebron - Model ZB-WAX - Fused Silica GC Column

    Zebron - Model ZB-WAX - Fused Silica GC Column

    Bonded, solvent rinsable phase excellent for separating polar complex mixtures. MS certified, low bleed levels. Low activity for amines. Excellent chromatography of polar complex mixtures; widely used for profiling and 'fingerprinting'.

  • Zebron - Model ZB-WAXplus - Fused Silica GC Column

    Zebron - Model ZB-WAXplus - Fused Silica GC Column

    Enhanced Aqueous Stability: 100 % aqueous stable, excellent for aqueous samples; bonded and solvent rinsable. Extremely inert for actidic compoundss. Enhanced selectivity for low boiling solvents. High retention of alcohols and chlorinated solvents. Increased efficiency at 20 °C.

  • Zebron - Model ZB-FFAP - Fused Silica GC Column

    Zebron - Model ZB-FFAP - Fused Silica GC Column

    High polarity column with excellent thermal and chemical stability. Provides better peak shape for underivatized acids. Especially suited for organic acids, free fatty acids, and alcohols. Bonded, solvent rinsable FFAP phase. Replaces OV-351.

  • Zebron - Model Z-Guard - Fused Silica GC Guard Column

    Zebron - Model Z-Guard - Fused Silica GC Guard Column

    Protect and Extend Column Lifetime. Z-Guard columns are universal GC guard columns, designed for use with virtually any GC capillary column, from virtually any manufacturer: Extend column lifetime by preventing stationary phase damage. Improve separation, peak shapes (especially early elutors), sensitivity, and accuracy of quantitative results.

  • Zebron - Model ZB-SemiVolatiles - Meet EPA 8270D Requirements Out-of-the-Box

    Zebron - Model ZB-SemiVolatiles - Meet EPA 8270D Requirements Out-of-the-Box

    Meet EPA Method 8270D Requirements Out-of-the-Box! This new technology delivers improved performance for challenging semi-volatile analyses such as PAHs, phenols, and amines. Improved peak shapes and responses are observed as a result of Enviro-Inert™ deactivation technology. While typical GC columns are QC tested for general requirements, the ZB-SemiVolatiles GC column is tested using a more stringent mix than the EPA 8270D tuning standard to...

  • Zebron GC Columns - ZB-CLPesticides-1

    Zebron GC Columns - ZB-CLPesticides-1

    Guaranteed, direct replacement to Restek Rtx -CLPesticides columns, Resolve multiple chlorinated pesticide classes on one pair with enhanced, fine-tuned selectivity, Meet requirements for 7 EPA methods by GC/ECD (8081, 8082, 8151, 504, 505, 508, and 552), Instantly save on every ZB-CLPesticides column and kit with everyday low pricing

  • GC Accessories

  • Zebron PLUS - GC Inlet Liners

    Zebron PLUS - GC Inlet Liners

    Optimized for trace and active compound analysis, Zebron PLUS GC liners undergo a unique chemical deactivation treatment resulting in a remarkably inert GC inlet liner.

  • Cool-Lock - Nut for GC Column Installation

    Cool-Lock - Nut for GC Column Installation

    The Cool-Lock Nut is a unique device (patent pending) that simplifies GC column installation and eliminates the need for wrenches or other tools. The low thermal mass design allows the Cool-Lock Nut to cool rapidly, preventing users from burning their fingers during column changes. Other unique design elements prevent the column from slipping to ensure a more reproducible installation depth for improved method accuracy. Since 80 to 90 percent of all...

  • Easy Seals Inlet Base Seals

    Easy Seals Inlet Base Seals

    Oxygen leaks?  Poor peak shape?  Reduce GC column degradation and breakdown of active compounds such as acids, bases, and pesticides with Phenomenex® Easy Seals™.  Designed with a softer metal alloy than traditional inlet base seals, Easy Seals make proper GC inlet base seal installation easier by reducing the torque required to create a tight seal and minimizing the opportunity for leaks.  Easy Seals do not...

  • Sample Preparation

  • Strata-X - Polymeric SPE Sorbents

    Strata-X - Polymeric SPE Sorbents

    Unique polymeric selectivities that cover a diverse spectrum of analytes, simplifying the method development process for fast and efficient sample preparation.

  • Strata - Silica-based SPE Sorbents

    Strata - Silica-based SPE Sorbents

    With over 25 chemistries to choose from, Strata Silica SPE products provide a wide range of diversity for customized method developmen.

  • Strata Florisil

    Strata Florisil

    Pesticide residue-grade SPE tubes provides extraction of pesticides from environmental samples. Part of the Strata SPE product line, which embodies quality and performance. Its extensive quality control procedure provides trouble-free solid phase extraction methods. All Strata SPE phases and formats are the result of a sophisticated manufacturing process - eliminating variability. Every product undergoes comprehensive QC testing to ensure reproducible...

  • Size Exclusion Solution

  • Chiral Solutions

  • Lux - Polysaccharide HPLC Chiral Columns

    Lux - Polysaccharide HPLC Chiral Columns

    Optimize your chiral separation with Lux ® polysaccharide HPLC chiral columns. The Lux family of amylose and cellulose chiral selectors provides a variety of complementary selectivities that allow you to screen for the most effective chiral separation under Reversed Phase, Polar Organic, Normal Phase, and SFC conditions.

  • HPLC and UHPLC Columns - Kinetex

  • HPLC and UHPLC Columns - Luna

  • Luna - Model C8(2) Phase - HPLC Columns

    Luna - Model C8(2) Phase - HPLC Columns

    Octyl silane groups bound to the silica surface with non-polar end capping offer moderate hydrophobic selectivity and virtually eliminate silanol interactions.

  • Luna - Model NH2 Phase - HPLC Columns

    Luna - Model NH2 Phase - HPLC Columns

    Amino groups bound to the silica surface serve as a weak anion exchanger and offer polar selectivity under reversed phase and normal phase conditions.

  • Luna - Model PFP(2) Phase - HPLC Columns

    Luna - Model PFP(2) Phase - HPLC Columns

    Pentaflourophenyl groups bound to silica surface for a unique aromatic selectivity due to highly electronegative fluorine atoms on the periphery of the phenyl ring ligand.

  • HPLC and UHPLC Columns - Synergi

  • Synergi - Model Hydro-RP Phase - HPLC Columns

    Synergi - Model Hydro-RP Phase - HPLC Columns

    A polar endcapped C18 phase that provides extreme hydrophobic and slight polar selectivity. Extreme retention of hydrophobic compounds. Slight polar selectivity. Stable in 100 % aqueous mobile phase.

  • Synergi - Model Max-RP Phase - HPLC Columns

    Synergi - Model Max-RP Phase - HPLC Columns

    Densly bonded C12 phase providing an alternative hydrophobic selectivity to traditional C18 columns. Hydrophobic retention similar to a C18 with improved results. Sharper peaks for basic and tailing compounds.

  • Synergi - Model Polar-RP Phase - HPLC Columns

    Synergi - Model Polar-RP Phase - HPLC Columns

    A polar endcapped, ether-linked phenyl phase providing polar and aromatic reversed phase selectivity. Increased retention of highly polar and aromatic compounds. Highly reproducible and stable phenyl phase. Enhanced polar resolution in 100 % buffer mobile phases.

  • HPLC and UHPLC Columns - Gemini

  • Gemini - Model C18 Phase - HPLC Columns

    Gemini - Model C18 Phase - HPLC Columns

    Unique selectivity, high structural integrity and increased loadability make it ideal for preparative and purification applications in pre-packed columns and bulk media.

  • Gemini - Model NX-C18 Phase - HPLC Columns

    Gemini - Model NX-C18 Phase - HPLC Columns

    Rugged Gemin column: Control selectivity of ionziable compounds for optimized methods. Consistent performance in both volatile and non-volaitle buffers. High and low pH methods.

  • Novum - Simplified Liquid Extraction (SLE) Tubes

    Novum - Simplified Liquid Extraction (SLE) Tubes

    Novum Simplified Liquid Extraction (SLE) (patent pending) products are a FASTER, EASIER, and MORE RELIABLE way to perform liquid-liquid extractions.  In 3 easy steps and less than 15 minutes, you can remove unwanted interferences such as salts, proteins, phospholipids and more from a variety of samples without performing extensive method development. Available in several capacities, Novum SLE is an excellent cleanup solution for a wide range of...