24 products found
Phenomenex, Inc. Products
-
Zebron GC Products
-
Zebron - Model ZB-1 - GC Columns
Low Polarity for a Wide Range of Applications; Rugged, high efficiency, and MS Certified low bleed. Well-suited for true boiling point separations. Excellent resolving power of critical pairs in complex petrochemical samples. Used for “fingerprinting” and routine quality control analyses (e.g., citrus ...
-
Zebron - Model ZB-5 - GC Columns
Low Polarity for a Wide Range of Separations; Versatile column recommended for a wide range of applications. Great column for unknown samples. Resilient to dirty samples – long column ...
-
Zebron - Model ZB-35 - Fused Silica GC Column
Low Bleed, Intermediate Polarity Selectivity for GC/MS; Intermediate polarity column for high molecular weight analysis. Inert to minimize analyte adsorption, improve efficiency, and reproducibility. More rugged (longer column life) than other polar phases. Excellent for trace analysis with bleed-sensitive detectors (MS, FID, ECD, ...
-
Zebron - Model ZB-50 - Fused Silica GC Column
Rugged Performance for High Polarity Selectivity; High polarity column capable of high temperature bakeout to remove contaminants. Inert to minimize analyte adsorption, improve efficiency, and reproducibility. More rugged (longer column life) than other polar phases. Great for toxicology and environmental ...
-
Zebron - Model ZB-1701 - GC Columns
Alternate Selectivity for Mid-Polarity Analyses; Fast run and re-equilibration times for enhanced sample throughput and productivity. Provides alternate selectivity to phenyl phases with similar ...
-
Zebron - Model ZB-1701P - Fused Silica GC Column
Specially tested to ensure response of DDT, Endrin, Endrin Aldehyde, and Endrin Ketone. Guaranteed column for pesticide analysis. Equivalent to USP Phase G46, EPA Method 8081 ...
-
Zebron - Model ZB-1MS - Fused Silica GC Column
Low Bleed Performance for GC/MS: Very low bleed (MS Certified) especially suited to high sensitivity GC/MS. Improved signal-to-noise ratio for better sensitivity and mass spectral integrity. Extremely inert for active compounds such as drugs, pesticides, acids, and ...
-
Zebron - Model ZB-1HT Inferno - High Temperature Fused Silica GC Column
Inferno: Rugged Performance Up to 430 °C: Rugged, high temperature stable (430 °C), polyimide-coated fused silica phase. Robust column performance for high temperature bake outs. True boiling point separation for hydrocarbon distillation methods. Recommended for chemists struggling with high boilers, contaminants, or ...
-
Zebron - Model ZB-1XT SimDist - Metal Column
New Glass Infusion technology provides higher efficiency and greater column-to-column reproducibility. Increased accuracy for high temperature simulated distillation analysis. Up to 70 % more efficiency than other columns. Improved resolution of ...
-
Zebron - Model ZB-5MS - Fused Silica GC Column
Low Bleed Performance for GC/MS; Most popular starting column for method developers. Arylene Matrix Technology (AMT) provides a highly stable arylene phase for enhanced resolution of PAHs and multi-ring aromatic compounds. Low bleed (MS certified) especially suited to high sensitivity work using ...
-
Zebron - Model ZB-5MSi - Fused Silica GC Column
Highly inert for improved peak shape of acidic/basic compounds, drugs of abuse, and pesticides. MS certified low bleed levels provide maximum sensitivity. Industry leading QC specifications ensure column-to-column performance. Traditional bonding chemistry provides the same selectivity as the ZB-5 ...
-
Zebron - Model ZB-5HT Inferno - High Temperature Fused Silica GC Column
Non-metal, high temperature stable (430 °C), MS Certified phase for high boiling compounds. Rugged high temperature, polyimide coated, fused silica tubing. Robust column performance for high temperature bake ...
-
Zebron - Model ZB-XLB - Fused Silica GC Column
Unique low polarity si-arylene column for MS detectors. Provides alternative selectivity to standard 5-type phases. Often used for confirmation of pesticide, PCB, or other environmental sample. Good tool for sample screening to identify unknown ...
-
Zebron - Model ZB-XLB-HT Inferno - High Temperature Fused Silica GC Column
Non-metal si-arylene GC column stable to 400 ˚C. Good tool for general screening to identify unknown samples. Rugged column performance for high temperature bakeouts. Individually tested for low bleed, MS ...
-
Zebron - Model ZB-MultiResidue-1 - Fused Silica GC Column
Specially designed for the separation of all types of pesticides, herbicides, and insecticides. Well-suited for dual column analysis with Zebron ZB-MultiResidue™-2. Performance exceeds US EPA Method 8081A specifications for chlorinated pesticides. Low activity, decreased breakdown of sensitive pesticides such as DDT. MS Certified phases provide low bleed performance for pesticide confirmation by MS. Chlorinated Pesticides EPA 8081A ...
-
Zebron - Model ZB-MultiResidue -2 - Fused Silica GC Column
Performance that exceeds US EPA Method 8081A specifications. Low activity, decreased breakdown of sensitive pesticides such as DDT. MS Certified phases provide low bleed performance for pesticide confirmation by ...
-
Zebron - Model ZB-624 - Fused Silica GC Column
Popular choice for residual solvent testing (USP Monograph). Widely used to separate volatile organic flavor and fragrance additives and residual solvents in industrial or pharmaceutical products (OVIs). Increased temperature limit speeds run times and re-equilibration. Formulated for low ...
-
Zebron - Model ZB-35HT Inferno - High Temperature Fused Silica GC Column
First non-metal, enhanced durability 35 %-phenyl phase witih 400 °C temperature stability. Great for high molecular weight compounds. Individually tested for low bleed, MS ...
-
Zebron - Model ZB-WAX - Fused Silica GC Column
Bonded, solvent rinsable phase excellent for separating polar complex mixtures. MS certified, low bleed levels. Low activity for amines. Excellent chromatography of polar complex mixtures; widely used for profiling and ...
-
Zebron - Model ZB-WAXplus - Fused Silica GC Column
Enhanced Aqueous Stability: 100 % aqueous stable, excellent for aqueous samples; bonded and solvent rinsable. Extremely inert for actidic compoundss. Enhanced selectivity for low boiling solvents. High retention of alcohols and chlorinated solvents. Increased efficiency at 20 ...
-
Zebron - Model ZB-FFAP - Fused Silica GC Column
High polarity column with excellent thermal and chemical stability. Provides better peak shape for underivatized acids. Especially suited for organic acids, free fatty acids, and alcohols. Bonded, solvent rinsable FFAP phase. Replaces ...
-
Zebron - Model Z-Guard - Fused Silica GC Guard Column
Protect and Extend Column Lifetime. Z-Guard columns are universal GC guard columns, designed for use with virtually any GC capillary column, from virtually any manufacturer: Extend column lifetime by preventing stationary phase damage. Improve separation, peak shapes (especially early elutors), sensitivity, and accuracy of quantitative ...
-
Zebron - Model ZB-SemiVolatiles - Meet EPA 8270D Requirements Out-of-the-Box
Meet EPA Method 8270D Requirements Out-of-the-Box! This new technology delivers improved performance for challenging semi-volatile analyses such as PAHs, phenols, and amines. Improved peak shapes and responses are observed as a result of Enviro-Inertâ„¢ deactivation technology. While typical GC columns are QC tested for general requirements, the ZB-SemiVolatiles GC column is tested using a more stringent mix than the EPA 8270D tuning standard to meet ...
-
Zebron GC Columns - ZB-CLPesticides-1
Guaranteed, direct replacement to Restek Rtx -CLPesticides columns, Resolve multiple chlorinated pesticide classes on one pair with enhanced, fine-tuned selectivity, Meet requirements for 7 EPA methods by GC/ECD (8081, 8082, 8151, 504, 505, 508, and 552), Instantly save on every ZB-CLPesticides column and kit with everyday low ...