TCR-Tecora

11 products found

TCR-Tecora Products

  • Industrial Emissions - Sampling Accessories

    Before and/or after the probe, TCR TECORA offers a wide range of sampling accessories following the International standard as required. Special “custom made” solutions are evaluated to solve the problems of a difficult sampling situation.

  • TCR Tecora - Isokinetic Filter Holders

    TCR Tecora - Isokinetic Filter Holders

    Filterholder for membrane diam. 47 mm in stack . A particular supporting system of filtering membrane guarantees an homogenous distribution of the particulate matter and the retention of the membrane itself during the filterholder disassembly.

  • TCR Tecora - Isokinetic Probes for Curves and Nozzle

    TCR Tecora - Isokinetic Probes for Curves and Nozzle

    In-stack filter application curve and interchangeable nozzles according to ISO 9096 and EN 13284. The drawing of this curve is in accordance with the international laws in force regarding isokinetic sampling. It is entirely made of either INOX 316 or titanium and is compatible with all TCR Tecora filter holder and probes equipped with cone shaped male connector with metal to metal joints.

  • TCR Tecora - Model PM10 - Stack Cyclone

    TCR Tecora - Model PM10 - Stack Cyclone

    The PM10 cyclone produced by Tecora allows to measure the fine particulate course in stack emission with aerodynamicdiameter lower than 10 micron. The cyclone has been designed following ISO 9001 standards and meets the specifications reported by USEPA Method 201A. This method concerns the sampling at constant flowrate at actual emission conditions using an in-stack filterholder. The PM10 cyclone can be installed on the Tecora Heated Probe,...

  • TCR Tecora - Outstack Filters

    TCR Tecora - Outstack Filters

    Kit to use the 47mm inox steel or titanium filterholder in the heated box. Using this kit, composed by two adapters, it’ possible to use the filterholder for 47mm flat membranes (see Emission Line 1.104.01) placing it in the heated box of the probe for micropollutants. The front connector fit to the outlet of the probe while the rear connector is equipped with a spherical joint fully compatible with all our glassware kits. The kit is available...

  • TCR Tecora - Instack Filters

    TCR Tecora - Instack Filters

    Inox Filterholder: It is possible to use the filterholders described in Product Data 1.104.02 'Isokinetic Filter Assembly'.

  • TCR Tecora - Model MCS2 - Isokinetic Heated Probe for PCDD/F

    TCR Tecora - Model MCS2 - Isokinetic Heated Probe for PCDD/F

    Condensing and adsorbing device MCS2 for the determination of PCDD/PCDF in compliance to EN 1948 Method. The EN 1948-1 “Filter condenser” method foresee the isokinetic sampling with a heated probe, filterholder and adsorbing trap XAD2/PUF after the condenser.

  • TCR Tecora - Model USEPA MCS2 - Condensing and Adsorbing Device

    TCR Tecora - Model USEPA MCS2 - Condensing and Adsorbing Device

    Condensing and Adsorbing Device EPAMCS2 for the Determination of PCDD/PCDF in Compliance to EPA 23 and EN 1948 Method. The EPA 23 and EN 1948-1 methods foresee the isokinetic sampling line with a heated probe, filterholder and XAD2 adsorbing trap for both gas and condensate.

  • TCR Tecora - Model US-EPA - Isokinetic Heated Probe

    TCR Tecora - Model US-EPA - Isokinetic Heated Probe

    Some EPA methods for compound sampling in gaseous phase are provided for using an impinger train that is placed on the back of the probe. The used configuration needs a sampling in gaseous phase are heated sampling probe with out stack provided for using an impinger train filter in accordance with US EPA 5 that is placed on the back of the Method. The special modularity realization of our probes allows the separation of the different elements for the...

  • TCR Tecora - Isoterm Thermoregulator Units

    TCR Tecora - Isoterm Thermoregulator Units

    The Isoterm thermoregulation devices are available in three different configurations that provide 1, 2 or 4 outputs. Through the electronic PID regulators it is possible to measure and control the heated temperature in a precise and effective way. The connections are unified to allow the widest versatility of use. In the 2 and 3 output models it is possible to insert alarm thresholds that activate a built-in sound and visual signal.

  • TCR Tecora - Model EN Acc - Standards Isokinetic Heated Probe

    TCR Tecora - Model EN Acc - Standards Isokinetic Heated Probe

    Some EN methods for the sampling of compounds in the gas phase involve the use of bubblers, on a derived stream,positioned downstream of the probe. The used configuration involves a heated sampling probe with external filter according to EN 13284 and EN 14385. The special designs of our probes allow to separate the different elements for easier management, and thus providing the ability to reconfigure them for different reference methods.