ambient air test Downloads

  • Premium

    HORIBA - APDA-371 - Ambient Dust Monitor Brochure

    The APDA-371 automatically measures and records airborne particulate concentration levels (in milligrams or micrograms per cubic meter), using the industry-proven principle of beta ray attenuation. Thousands of this Dust Analyzer units are currently deployed worldwide, making the unit one of the most successful air monitoring platforms in the ...


    By HORIBA Europe GmbH

  • Premium

    Metrohm Dosing Test Brochure

    Calibration of Metrohm dosing and exchange unitsMetrohm Dosing Test02Used every day – and always accurate ...Everyday useYour Metrohm dosing or exchange unit operates reliably day in, day out, or even overnight if so configured. It al ­ways dispenses an exact volume. The cylinder is filled with titrant before the sequence starts again.You base your decisions on the results obtained because you ...


    By Metrohm AG

  • Premium

    Air Sampling Consumables Solutions Brochure

    With over 200 years of history, Casella Measurement is today a reputable leader in the development, manufacture and supply of industrial hygiene, occupational health and environmental monitoring instrumentation. As a global company with offices and distributors worldwide, Casella CEL ensure quality service worldwide. The range of air sampling consumables within this catalogue compliment the ...


    By Casella

  • Ambient Industrial Air Cleaners Brochure

    www.industrial-maid.com 1-877-624-3247 INDUSTRIAL AIR CLEANERS T-SERIESBREATHE EASY WITH PRACTICAL, ENERGY-EFFICIENT AIR FILTRATION SOLUTIONS FROM INDUSTRIAL MAIDThe T-Series Industrial Air Purifiers are designed for fume extraction, welding smoke collection, industrial dust extraction, oil mist filtration and the capture of most airborne nuisance dusts, mist and vapors. These simple ...


    By Industrial Maid LLC

  • Ambient Air Monitoring Systems Brochure

    AMBIENT AIRMonitoring systemsPM10 Hg Nox CoVIsIBIlITyWe have over 35 years expertise in the design, supply, maintenance, engineering and operation of ambient air monitoring systems.Our systems provide high quality air pollution and meteorological data while reducing time spent on maintenance and calibration.Our systems are recognised all over the world because:• We have supplied ...


    By Ecotech Pty Ltd

  • Ambient Air Monitoring Program Support

    800-EPA-AIR1 www.aircomp.comAmbient Air MonitoringProgram SupportAmbient Air Monitoring can helpyou if you are involved in:• Constructing a new major stationary source• Making major modifications to your existingmajor source (e.g., replacing a boiler, addingnew process equipment)• Dispersion studies• An ambient air odor investigationAir ComplianceTesting provides complete, turnkeyon-site ...


    By Air Compliance Testing, Inc.

  • Premium

    AP-370 Series - Air Pollution Monitor Brochure

    Automatic calibration: Troublesome calibration procedures have been reduced to the push of a function key. At the Auto-Interval Calibration (AIC) menu you can set the start time, the start range, and the interval for the automatic calibration. The system clock and calendar then assure that your calibration instructions are executed precisely. To make things even easier, remote auto-calibration ...


    By HORIBA Europe GmbH

  • Premium

    Stack testing according to US EPA methods - application note

    GasmetTM FTIR application note Stack testing according to US EPA methods KEY WORDS • Emissions monitoring • Fourier Transform Infrared (FTIR) • EPA test methods 320, 321 • Hydrogen Chloride (HCl) OVERVIEW US EPA has two stack testing methods for FTIR. Method 320 is a FTIR method for measuring wide range of organic and inorganic pollutants from stack. Method 321 is a specific version for ...


    By Gasmet Technologies Oy

  • Premium

    Stack Testing According to U.S. EPA Methods (Application Note)

    GasmetTM in emissions monitoring – applications: Stack testing according to USEPA methods Stack testing US EPA has two stack testing methods for FTIR (Fourier Transform Infrared) - spectroscopy. Method 320 is an FTIR method for measuring wide range of organic and inorganic pollutants from stack. Method 321 is a specific version for measuring HCl at Portland cement plants. These ...


    By Gasmet Technologies Oy

  • Premium

    Stack testing according to US EPA methods - application note

    GasmetTM FTIR application note Stack testing according to US EPA methods KEY WORDS • Emissions monitoring • Fourier Transform Infrared (FTIR) • EPA test methods 320, 321 • Hydrogen Chloride (HCl) OVERVIEW US EPA has two stack testing methods for FTIR. Method 320 is a FTIR method for measuring wide range of organic and inorganic pollutants from stack. Method 321 is a specific version for ...


    By Gasmet Technologies Oy

  • Premium

    TAPI - Model 701 - Zero Air System - Manual

    OPERATION MANUAL MODEL 701 ZERO AIR GENERATOR TELEDYNE ADVANCED POLLUTION INSTRUMENTATION DIVISION (TAPI) 9480 CARROLL PARK DRIVE SAN DIEGO, CA 92121-5201 TOLL-FREE: 800-324-5190 FAX: 858-657-9816 TEL: 858-657-9800 E-MAIL: api-sales@teledyne.com WEB SITE: www.teledyne-api.com 01671H DCN6051Copyright 2007 – 2011 Teledyne Advanced Pollution Instrumentation 08 April 2011 01671H ...


    By Teledyne API

  • Ambient - CC2060 - Air-To-Water Heat Exchanger Brochure

    SPECIFICATIONS 1. UL Listed for TYPE 12 environments. 2. CC2060 Rated cooling: 980 Watts mounted to an uninsulated 24” x 24” x 16” Cabinet with 1 GPM of water at 20°C, 40°C ambient air and 60°C cabinet air temperature. ...


    By Noren Products

  • Premium

    HI-Q Air Sampling & Radiation Monitoring Equipment - 2016 Catalog

    For the Health Physics, Environmental & Nuclear IndustriesCatalog “W” 2012-13Flexible solutionsPartnering with VF, a.s. Table of Contents HI-Q2 7386 Trade Street / San Diego, CA 92121 / Phone 858-549-2820 / Fax 858-549-9657 / Order Online @ www.HI-Q.netCustom Engineering & Design Custom Engineering and Design Capabilities ............................................................. ...

  • Premium

    QuadraTherm 640i Air / Gas Thermal Insertion Mass Flow Meters - Datasheet

    From Sierra’s beginning over forty years ago, Founder Dr. John G. Olin was driven by the vision of supplying industrial customers with the world’s most accurate mass flow meter. And, he knew it was a “sensor” ...


    By Sierra Instruments, Inc.

  • Gen II Ambient Air Gas Sensor Assembly OI-6000K- Brochure

    Specifications • Sensor Type: Electro-chemical, Catalytic Bead, PID, or Infrared • Power: +12-35 Volts DC (with battery clips) 110/240 Volts AC (with cord grips and cable) • Current Draw: 1.25 A (max @ 24VDC) • Relays: 5 Amp relays with 4 Amp fuses • Output: 4-20mA (3-wire); RS-485 Modbus • Display: Graphical LCD, ...


    By Otis Instruments, Inc.

  • Model OI-6900 - Ambient Air Gas Sensor Brochure

    OI-6900 Sensor Assembly The Gen II Wire Free OI-6900 ambient air gas sensor assembly is a wireless gas sensor assembly that uses an electro-chemical sensor element to detect a variety of gases. The device comes standard with a 102 x 64 graphical LCD screen, standard three-button interface, custom explosion proof enclosure, non-intrusive magnetic switches, and radio (900MHz or 2.4GHz). The ...


    By Texcel Pty Ltd

  • Outdoor Air Quality Testing- Brochure

    When any proposed development is locatedwithin a designated Local Air QualityManagement Area, the local authority willrequire an Environmental Impact Assessmentas part of the planning application. Anoutdoor air quality evaluation must beincluded in this assessment. Where thedevelopment is small, the EnvironmentalImpact Assessment will focus on the impactof the local environment to occupants of ...

  • Premium

    Eijkelkamp - Model 08.65 - Air Permeameter for Soil Manual

    The air permeameter apparatus measures the permeability or conductance of an (undisturbed) soil sample. Air permeability is the property of the soil pore system allowing air to flow through. Generally the pore sizes and their connectivity determine whether a soil has high or low permeability. Air will flow easily through soil with large pores and good connectivity between them. Small pores with ...


    By Eijkelkamp Soil & Water

  • GC3009 Ambient Air Quality Analysis of Toxic Gases and Priority Pollutants by GC/TCD/FID - Application Notes

    Ambient Air Quality Analysis of Toxic Gasesand PriorityThe EPA regional offices who continuouslymonitor ambient air quality have determinedthat combustion by-products and automobileexhaust make up the largest source of airpollution throughout the U.S., with moresevere conditions existing overseas. Despiteconcerns about the conditions outdoors, airquality in the workplace and homeenvironment ...


    By Buck Scientific Inc

  • Air Quality Test Kit Manual Brochure

    Printed in U.S.A©Copyright Air Systems International, Inc. 2000. All Rights Reserved.AIR SYSTEMS INTERNATIONAL, INC.821 Juniper Crescent, Chesapeake, Va. , 23320Telephone (757) 424-3967Toll Free 1-800-866-8100 Fax No. (757) 424-5348 http://www.airsystems.cce-mail: sales@airsystems.ccOperating ManualModelsAQT-02 & AQT-COO2Manual No. MON004(Rev 2 April 2000)MarthaStampAir Systems International, ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you