benzene concentration Downloads

  • Percent Benzene in Gasoline

    Benzene is a naturally occurring com-pound in crude oil and a very useful chemical solvent and feedstock. Unfortu-nately, it can be a signi? cant health risk and is therefore environmentally regulated in many common products especially gasoline. Thus strict limits are put on the concentration and accurate measurements are required. The traditional analytical method for measuring benzene is gas ...

  • Novel Groundwater Remediation Strategy for Petroleum Hydrocarbons in Groundwater - Brochure

    Revised 2013 – 1101 Nowell Road, Raleigh, NC 27607 www.eosremediation.com – (919) 873-2204 Novel Groundwater Remediation Strategy for Petroleum Hydrocabons in Groundwater – A Paradigm Shift Retail Fuel Sales Facility, Indianapolis, Indiana. EOS Remediation, LLC Site Background and Regulatory History A retail fuel sales facility located in Indianapolis, Indiana has been in operation for more ...

  • Premium

    Acetaldehyde, Benzene, Toluene, Ethylbenzene & Xylenes in CO2 Application Note

    Analyzer The BevAlert Model 8900 provides direct measurement of Acetaldehyde, Benzene, Toluene, Ethylbenzene, and Xylenes (ABTEX) in Carbon Dioxide.The instrument is utilized by Specialty Gas Manufacturers and the Food and Beverage Industry to monitor trace volatile organic compounds in CO2 used in carbonated beverages.The BevAlert Model 8900 employs a photoionization detector (PID). The ...

  • Premium

    Vinyl Chloride, Acetaldehyde, Methanol and Benzene in CO2 Application Note

    AnalyzerThe BevAlert Model 8900 provides direct measurement of Vinyl Chlo-ride, Acetaldehyde, Methanol, and Benzene (VCAMB) in Carbon Dioxide.The instrument is utilized by Specialty Gas Manufacturers and the Food and Beverage Industry to monitor trace impurities in CO2 used in carbonated beverages. The BevAlert Model 8900 employs a photoionization detector (PID). The VCAMB in the gas sample are ...

  • Bedford, MA - Naval Weapons Industrial Reserve Plant Brochure

    Phone: 425.396.4266 dfleming@thermalrs.comTRS NWIRP ProjEx 010413 acf 1 Full Scale Remediation of Chlorinated Solvents and BTEX using ERH, Naval Weapons Industrial Reserve Plant, Bedford, Massachusetts This project involved simultaneous remediation of chlorinated solvents and benzene at two separate locations called Site 3 and Site 4 at the Naval Weapons Industrial Reserve Plant ...

  • Syntech Spectras - GC955-603 - 1,3-Butadiene Benzene Analyser Brochure

    The Syntech Spectras GC955 series 600 Butadiene Benzene analyser The Syntech Spectras GC955 series 600 Butadiene-Benzene analyser is built for the measurement of 1,3-butadiene and benzene, in ambient air. In the European regulations measurement of benzene in ambient air is now obligatory. The concentration of benzene varies from under 0.03 to above 100 micrograms per m3. 1,3-Butadiene is a ...

  • FROG-4000 BTEX Analysis

    ™Defiant Technologies Inc. 6814A Academy Parkway West NE Albuquerque, NM 87109-4406 Phone: 505-999-5880 x26 www.defiant-tech.com ajtrujillo@defiant-tech.com Authors: Amanda J. Trujillo, Douglas R. Adkins, Allister B. Hamilton, Patrick R. Lewis Monitoring ground water for volatile organic compounds (VOCs) that result from spills or leaks from industrial processes costs millions of dollars ...

  • Premium

    Acetaldehyde, Methanol and Benzene in CO2 Application Note

    AnalyzerThe BevAlert Model 8900 provides direct measurement of Acetaldehyde, Methanol, and Benzene (AMB) in Car-bon Dioxide.The instrument is utilized by Specialty Gas Manufacturers and the Food and Beverage Industry to monitor trace impurities in CO2 used in carbonated beverages. The BevAlert Model 8900 employs a photoionization detector (PID). The AMB in the gas sample are physi-cally ...

  • Bedford, OH - Brownfields Cleanup for Property Transfer Brochure

    TRS Group, Inc (TRS), as subcontractor to Clayton Group Services, provided Electrical Resistance Heating (ERH) for the guaranteed fixed price remediation of benzene in soil and groundwater for a site involved in a property transfer in Bedford, OH. The site contained very high VOC concentra-tions and free product was encountered during drilling for replacement monitoring wells. The remedial goals ...

  • Premium

    Terpenes analysis in ambient air

    Case Study N°AA5 – Ambient air monitoring – Terpenes – updated: 19.10.15 sales@chromatotec.com www.chromatotec.com Ambient Air Monitoring Applications Low level measurement of VOCs and Terpenes close to the sea and the Landes Forest Context & Challenges It has been established that organic aerosol (OA) makes up for a major fraction of fine particulate matter in all region of the ...

  • Premium

    BTEX in Ambient Air Application Note

    Analyzer The Series 8900 BTEX Analyzer provides direct measurement of Benzene, Toluene, Ethylbenzene, and Xylenes in ambient air. This instrument is utilized in ambient air networks around metropolitan areas and fence-line monitoring at indus-trial sites.The Series 8900 BTEX Analyzer employs a photoionization detector (PID) as the sensing element. This detector is specific to volatile ...

  • Premium

    Impurities Measurement in Gaseous Carbon Dioxide

    www.chromatotec.com E X P E R T S I N G A S A N A L Y S I S The problem CO2 used in food industries can be produced by two families of processes: natural or chemical The multiple production possibilities are involving different kind of impurities inside CO2 (BTEX, Sulfur compounds…). To help producers to control the quality and purity of Carbon Dioxide, ...

  • Application - Determination of benzene in gasoline

    INFRARED FOURIER SPECTROMETER InfraLUM® FT-08 DETERMINATION OF BENZENE IN GASOLINE GOST 51930-2002 ASTM D 4053-04(2009) EN 238-2004 INTRODUCTION Benzene is formed in gasoline in the process of oil refining and gasoline production. Determination of benzene in gasoline is an important task, because benzene and its products reacting with the products of incomplete combustion of gasoline are ...

  • Synspec - Alpha 400 - Benzene Analyser Brochure

    ALPHA 400 MEASURING PRINCIPLE: Alpha is a compact GC containing all the essential elements: preconcentration sampling unit, backflush valve, separation column in special small oven unit and detector. The detector is a PID. The gas sample is concentrated in a TRAP. The sample is then desorbed and injected over the valve into a column and benzene passes on to the detector. The system is ...

  • Premium

    BTEX in Ambient Air using a High-Sensitivity PID Application Note

    Analyzer The Series 8900 BTEX Analyzer with a high-sensitivity PID provides direct low level measurement of Benzene, Toluene, Ethylbenzene, and Xylene's in ambient air. This instrument is uti-lized in ambient air networks around metropolitan areas and fence-line monitoring at industrial sites.The Series 8900 BTEX Analyzer employs a high-sensitivity photoion-ization detector (PID) as the ...

  • Application - Identification of drugs and medicines

    INFRARED FOURIER SPECTROMETER InfraLUM® FT-08 DETERMINATION OF BENZENE IN GASOLINE GOST 51930-2002 ASTM D 4053-04(2009) EN 238-2004 INTRODUCTION Benzene is formed in gasoline in the process of oil refining and gasoline production. Determination of benzene in gasoline is an important task, because benzene and its products reacting with the products of incomplete combustion of gasoline are ...

  • Premium

    AirmoVOC BTX Benzene / Toluene / Ethylbenzene / Xylenes Analyzer Brochure

    EXPERTS IN GAS ANALYSIS WWW.CHROMATOTEC.COMTSP A21 BTEXUpdated: October 2013Model : A21022 with integrated PCGAS ANALYZER GC 866Applications of the airmoVOC BTEX :Benzene, toluene, ethylbenzene, xylenesEnvironment:Monitoring of urban and non-urban pollutionMonitoring of industrial nuisanceIndustrial:Industrial health and safety monitoringProcess Qulaity ControlOther Applications:Waste ...

  • EPA Air Monitoring Tools and Techniques Datasheet

    Air Monitoring Tools & Techniques Practical Applications for Savvy Air Investigators Outline Optical Remote Sensing (ORS) Tools: 1) Passive Fourier Transform Infrared (FTIR) 2) Ultraviolet Differential Optical Absorption Spectroscopy (UV-DOAS) 3) Open-Path FTIR (OP-FTIR) 4) Tunable Diode Laser (TDL) 5) Cavity Ring-Down Spectroscopy (CRDS) Readily Available Tools & Techniques 1) Photo-Ionization ...

  • Tiger Select Brochure

    Best proven photoionisation (PID) detection• PID independently verified as best performing on the market• Unrivalled sensitivity detects down to ppb levels • Selectively detects benzene with Draeger pre-filter tube• Continuous readings shown as max level reached• In-built humidity resistance with no need to compensate• Anti-contamination design for extended field operationMinimise downtime• Ready ...

  • VOC RAM Technical Data Sheet

    Technical Data Sheet: TDS 17 DIFRAM-VOC: RAPID AIR MONITOR - VOCs Description: A plastic (H.D.P.E.) circular diffusive sampler containing a sorbent for measuring gaseous volatile organic compounds in ambient air. This sampler is designed to provide a considerably higher uptake rate than the passive axial diffusion tube, and allows a higher flexibility of air pollution monitoring in outdoor and ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you