chromatography measurement Downloads

  • Applications Note: Ammonia Monitoring (PDF 952 KB)

    Ultra-Sensitive Ammonia Measurements Measurement and control of ammonia is critical in a variety of industrial applications including power generation, petrochemical processing, and semiconductor manufacturing. In many cases, ammonia measurement at ppb levels is required to achieve optimal process control or safeguard valuable work-in-process material. Ammonia is difficult to measure ...

  • Hitachi LaChrom - Elite - HPLC Control Module - Brochure

    www.dataapex.comCLARITY SOFTWARECONTROLSEXTENSIONSHARDWAREClarity Control Hitachi LaChrom Elite HPLCDirect control of Hitachi HPLC systems using Clarity Chromatography SoftwareThe Clarity Chromatography Station allows for direct control of the Hitachi HPLC systems through USB port.The optional control module includes parameters for the HPLC pumps, column oven, detector , autosampler, etc. ...

  • Analysis of Halogens Technical Note

    6 Wentworth Drive • Hudson, NH 03051 U.S.A. Tel: 603 886 8400 • Fax: 603 886 9141 • www.leemanlabs.com Introduction There are many applications where the ability to measure the halogen elements, at the same time as the metallic elements, is desirable. A few of these include the measurements of Cl and Br in refinery process fluids, the measurement of Cl and Br in waste oils and the ...

  • Pneumatic Focusing Gas Chromatography (PFGC) Flyer

    VOC Technologies phone: 1-503-936-6619 (US) www.VOCTEC.com Pneumatic Focusing Gas Chromatography Continuous, web-based, Air Monitoring ----- The GC-in-a-PC VOCTEC patented* Pneumatic Focusing Gas Chromatograph (PFGC=the GC-in-a-PCTM) Pneumatic focusing gas chromatography (PFGC, patented*) is a continuous, specialized monitor for volatile organic compounds (VOCs), Hazardous ...

  • MixSplitter - Raman Qualitative and Quantitative Analyzer of Powders Brochure

    Detect Additives with MixSplitterinfo@enspectr.com www.enspectr.com• Up to 0.1% contaminant identi?cation• Portable tool for Trace Forensics• Analyses in situ• 20 minutes for analysis• No special skills required• Favorable priceNo more week-time waiting for expensive andcomplicated lab only analyses by meansof chromatography / ?hromatomass-spectrometryReveal hidden properties of mixed ...

  • Percent Benzene in Gasoline

    Benzene is a naturally occurring com-pound in crude oil and a very useful chemical solvent and feedstock. Unfortu-nately, it can be a signi? cant health risk and is therefore environmentally regulated in many common products especially gasoline. Thus strict limits are put on the concentration and accurate measurements are required. The traditional analytical method for measuring benzene is gas ...

  • URG 9000A Ambient Ion Monitor Brochure

    URG 9000 SeriesAmbient Ion MonitorMeasurement CapabilitiesThe 9000 Series Ambient Ion Monitors consist of four configurations. The URG-9000A Ambient Ion Monitor (AIM) provides time-resolved direct measurements of anion particulate Nitrate, Sulfate, Nitrite, Phosphate and Chloride found in PM-2.5. Nitrite and Sulfate aerosols are produced as a result of the interaction of ammonia (NH3), NOx, SO2 ...

  • Percent Aromatics in Gasoline

    The aromatic content of gasoline determines many of its combustion properties. Since it also impacts the environmental characteristics of the fuel it is desirable to have accurate measurements of this parameter. The traditional analytical method for measuring aro-matics is either gas chromatography (GC) or an older method entitled fl uorescent indicator adsorption (FIA), both of which are time ...

  • Clarity Key Parameters Brochure (PDF 67 KB)

    Podohradská 1, CZ 15500 Prague, The Czech RepublicChromatography Softwarefrom Chromatography SpecialistsDataApexClari ty www.dataapex.com | ISO9001 certified Code/Version: D006/EN05-20070510 Tel.: +420 251 013 400 (401 fax) Page 1 of 2 Clarity Chromatography Station – key parameters Description: Chromatography software for data acquisition and data processing SW Package: SW on a CD, HW key ...

  • Clarity EA Brochure (PDF 393 KB)

    Clarity EA ExtensionSoftware module for Elemental AnalysisDetermining the Carbon, Hydrogen, Nitrogen, Oxygen, and Sulphur (CHNS-O) content of unknowns is one of the most basic and essential needs of any chemist.EA Extension provides a simpli?ed version of the Clarity user interface that speeds up the work?ow with elemental analyzers equipped by autosamplers.EA Extension is an optional addition to ...

  • Info Flash 10 DAD 800 detector

    P/N 2053E00X ECOM spol. s r.o. Tel: +420 221 511 310 www: http://www.ecomsro.com/ Americka 3, 120 35 Praha 2, Czech Republic Fax: +420 242 498 212 E-mail: info@ecomsro.cz FLASH 10 DAD 800 DETECTOR is an UV-VIS diode array detector, which allows measuring absorbance of four wavelengths simultaneously in one cell just as measuring of whole spectrum (scan). More wavelengths are used in liquid ...

  • Clarity Hardware CB20 Brochure (PDF 168 KB)

    Podohradská 1, CZ 15500 Prague, The Czech RepublicChromatography Softwarefrom Chromatography SpecialistsDataApexClari ty www.dataapex.com | ISO9001 certified Code/Version: D003/EN02-20070615 Tel.: +420 251 013 400 (401 fax) Page 1 of 2 Clarity Hardware - CB20 card D/A and D/f converter for PCI CB 20 is a control card that enables direct gradient control of HPLC Pumps The CB20 card is designed ...

  • Ammonia RAM Technical Data Sheet

    Technical Data Sheet: TDS 18 DIFRAM400: RAPID AIR MONITOR – Ammonia, NH3 Description: A plastic (H.D.P.E.) circular diffusive sampler containing a sorbent for measuring gaseous Ammonia in ambient air. This sampler is designed to provide a considerably higher uptake rate than the passive axial diffusion tube, which allows a higher flexibility of ambient air pollution measuring in outdoor and ...

  • Ammonia Rapid Air Monitor Tech Sheet

    TDS18 Ver1 April 2013 Technical Data Sheet: TDS 18 DIFRAM400: RAPID AIR MONITOR – Ammonia, NH3 Description: A plastic (H.D.P.E.) circular diffusive sampler containing a sorbent for measuring gaseous Ammonia in ambient air. This sampler is designed to provide a considerably higher uptake rate than the passive axial diffusion tube, which allows a higher flexibility of ambient air pollution ...

  • Ammonia Rapid Air Monitor Technical Data Sheet

    Technical Data Sheet: TDS 18 DIFRAM400: RAPID AIR MONITOR – Ammonia, NH3 Description: A plastic (H.D.P.E.) circular diffusive sampler containing a sorbent for measuring gaseous Ammonia in ambient air. This sampler is designed to provide a considerably higher uptake rate than the passive axial diffusion tube, which allows a higher flexibility of ambient air pollution measuring in outdoor and ...

  • Clarity - - Chromatrography Data System Brochure

    www.dataapex.com e-mail: clarity@dataapex.com...............................................................DESCRIPTIONDataApex Clarity 32bit multi instrument chromatography station for WindowsMulti-detector instrumentsEasy to install and easy to useGraphical user interfaceTools for GLP and 21 CFR Part 11Add on control modulesOn-line user supportExcellent price/performance rate data solution ...

  • DataApex - Clarity Software - Brochure

    www.dataapex.comCLARITY SOFTWARECONTROLSEXTENSIONSHARDWAREClarityChromatography Software from Chromatography SpecialistsClarity is advanced chromatography data station with software modules for data acquisition, data processing, and instrument control.Its wide range of data acquisition interfaces (A/D converters, LAN, USB, RS232) allows connection to virtually any chromatograph.• Easy to install ...

  • Premium

    Determination of Serum Protein Fractions - Application Note

    HIGH PERFORMANCECAPILLARYELECTROPHORESIS SYSTEM CAPEL® series 80 mAU5 6 7 8 9 10 11 12 13 14 min?-Gl ß2-Glß1-Gla2-Gl a1-Gl Alb PreAlb DETERMINATION OF SERUM PROTEIN FRACTIONS INTRODUCTION The method allows determination of relative amounts of albumin and globulins in human serum using capillary electrophoresis methods. MEASUREMENT METHOD Determination of albumin and globulins of the human ...

  • Premium

    VOCs monitoring in water using Purge&Trap instrument

    Case Study N°AA7 – Ambient air monitoring – VOC Purge & trap – updated: 09.10.15 sales@chromatotec.com www.chromatotec.com Ambient Air Monitoring Applications Analysis of VOC compounds in water by Purge & Trap or dynamic headspace Context & Challenges Volatile organic compounds (VOC) can be dissolved in water. Sometimes water is polluted and to study contamination of VOC in ...

  • Clarity Brochure PRINT (PDF 2.828 MB)

    www.dataapex.comCLARITY SOFTWARECONTROLSEXTENSIONSHARDWAREClarityChromatography Softwarefrom Chromatography SpecialistsClarity is advanced chromatography data station with software modulesfor data acquisition, data processing, and instrument control.Its wide range of data acquisition interfaces (A/D converters, LAN, USB, RS232)allows connection to virtually any chromatograph.• Easy to install and ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you