contaminated soil sample Downloads

  • X-ray Detectors-XPIN-BT Series

    Portable/ Benchtop XRF¦ RoHS/WEEE¦ Light element analysis¦ Metallurgy¦ Alloy sorting¦ Scienti? c research¦ Nuclear monitoring¦ Quality control¦ Brand protection¦ Coating analysis¦ Plastic additive analysis¦ Soil analysis¦ OSHA compliance¦ Contamination sampling¦ Archeology¦ Art authentication¦ Forensic¦ Mobile crime labsApplicationsThe XPIN® detector is Moxtek’s best performing Si-PIN detector. ...

  • Premium

    Heated Soil Analysis (Heated Golden Gate ATR) - Application Note

    Object MovedThis document may be found ...

  • Membrane Interface Probe

    www.numac.com.au | 1300 131 019 | Melbourne | Sydney | BrisbaneDrilling is just the beginning ...Subsurface SamplingThe Membrane Interface Probe (MIP)Numac’s Subsurface Sampling process uses Membrane Interface Probe (MIP), a rapid, cost-effective method of delineating volatile organic contaminants (for example, BTEX, TCE, DCE) in real time and at depth. MIP effectively locates zones where dense ...

  • Triathler

    All in one Liquid Scintillation Counter,Gamma Counter and LuminometerInstant results whenever and wherever with thiscompact and portable counting systemEasy-to-UseTriathler is a single sample counter which provides fast and accurate results for several life science and environmentalapplications. It can count all radioisotopes including tritium in a variety of sample formats. Due to its very small ...

  • Jamaica Queens, New York Brochure

    TRS NY04 projex 112309 acf.doc 1 Guaranteed Performance Based Remediation of Tetrachloroethene Queens, New York This project involved a guaranteed source area remediation of tetrachloroethene (PCE) at an operating school bus maintenance facility located in Queens, New York. Engineer: Mr. Greg Beyke Project Superintendent: Mr. Paul Bianco Lithology: Clean sand in both the vadose and ...

  • Waukegan, Illinois Brochure

    ERH Remediation of Methylene Chloride in the Vadose Zone Waukegan, Illinois Contaminants Treated: Methylene Chloride Starting Contaminant Levels: 42,000 mg/kg Treatment Volume: 16,000 cubic yds Cleanup Levels Achieved: Exceeded Goals - 99.8% average reduction of MeCl in soil Geology: Glacial till with silty clay Hydrology: Perched groundwater at various depths Remediation Time Period: December ...

  • Specification

    35? Ponomarenko str. room 4 220015 Minsk Republic of Belarus e-mail: info@timet.ru Phone/fax: +375 17 2027665 Phone: +375 17 2513433 Mobile: +375 33 6388963 http://www.timet.ru GAMMA RADIATION MONITOR ??S-01 «SOVETNIK» APPLICATION Portable scintillation gamma radiation monitor, possessing high sensitivity and a big set of the functions intended for in situ measurement of specific ...

    By Timet

  • Southside Chicago - PCE Remediation in Active Alley Brochure

    Under contract to Malcolm Pirnie, TRS Group, Inc. (TRS) designed, installed and operated the ERH remediation sys-tem at this dry cleaner facility in an active alley behind a shopping mall. The goal of the remediation project was to reduce tetrachloroethene (PCE) concentrations in soil to less than 11 milligrams per kilogram (mg/kg). While site soil also contained other chlorinated volatile ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you