continuous speciating mercury testing Downloads

  • 915 J Mercury CEM Brochure

    915 J Mercury CEM Real-Time Mercury Measurement Process Monitor 915 J Mercury CEM Real-Time Mercury Measurement Process Monitor your partner for mercury testing your partner for mercury testing With a pedigree of 15 years in mercury instrumentation, hundreds of stack testers, ...

  • ACS Environmental Data Sheet Brochure

    ENVIRONMENTALACS Environmental Testing Ltd was established in 2006 and is a state of the art ISO 17025 accredited analytical laboratory specialising in routine testing of contaminated soils, sludges, aggregates and waters for heavy metals, inorganic and organic determinands.We deliver quality results to Environmental Consultancies, Ground Investigation, Remediation, Quarry, Recycling and Waste ...

  • Premium

    Tekran - Model 3300Xi - HgCEM System - Brochure

    230 Tech Center Drive, Knoxville, TN 37912 USA Ph: +1-865-688-0688 Fax: +1-865-766-8422 ? www.tekran.com ? cemparts@tekran.com WHERE MEASUREMENT BEGINS MERCURY (Hg) FLUE GAS INLET-OUTLET MEASUREMENT NEW Tekran 3300Xi Dual-Probe HgCEM System SYSTEM OVERVIEW The Model 3300Xi Dual-Probe HgCEM System is the next generation of Tekran’s proven HgCEM mercury emission ...

  • Mercury Air Cooled Probe Flyer

    Mercury Air Cooled ProbeAir-Cooled Probes in High TemperatureStack Gas EnvironmentsPart Number DescriptionHGPA-4-HSo 4 Foot ProbeHGPA-6-HSo 6 Foot ProbeHGPA-9-HSo 9 Foot ProbeHGPA-12-HSo 12 Foot ProbeAir-Cooled Mercury ProbesLosing Test Runs & Data Because of Excessive Temperatures? Apex Air-Cooled Sorbent Trap Probes are the Solution.www.apexinst.com800-882-3214 / 919-557-7300Air Cooled ...

  • SOP - Speciation Trap Analysis Procedure Manual

    SPECIATION TRAP ANALYSIS PROCEDURE Subject Mercury Emissions Monitoring Program Speciation Sorbent Trap Analysis Prepared by Analytical Laboratory of Ohio Lumex Company Revised on January 21st, 2013 9263 Ravenna Rd., Suite A-3 Twinsburg, OH, 44087 Toll Free: 888-876-2611 Fax: 330-405-0847 2 CONTENTS ...

  • Premium

    Tekran - Model 3310 - Elemental Mercury (Hg) Calibration Unit - Brochure

    330 Nantucket Boulevard, Toronto, Canada M1P 2P4 lab-air-info@tekran.com Tel:+1-416-449-3084 Fax: +1-416-449-9298 Toll Free: (US and Canada) 1-888-383-5726 (1-888-3-TEKRAN) WHERE MEASUREMENT BEGINS™ - Page 1 of 2 - Model 3310 – Elemental Mercury Calibration Unit Rev 124 Order & technical support : ...

  • XC-6000 MercSampler Sorbent Trap Brochure

    Mercury Emissions MonitoringCompliance Monitoring Solutions for MATSMercurySorbent TrapsOur goal is to provide you with all of your Mercury sampling solu-tions from the sorbent traps to the reporting. You can rely on us to help you meet your sampling deadlines. With the passing of more stringent EPA mercury emission regulations for coal-fired power plants, cement kilns and other combustion ...

  • MCERTS Stack Emissions Monitoring and Consultancy

    MCERTS Stack Emissions Monitoring and ConsultancyAccurate monitoring and characterisation of stack emissions is important for regulatory and process control requirements. NPL provides a professional and competitively priced MCERTS/UKAS-accredited stack monitoring and compliance testing service utilising industry standard techniques.Key operational features of the service include:XX ...

  • Premium

    Relative Accuracy Testing of XRF Mercury Monitor - Technical Literature

    This article was downloaded by: [50.246.240.253]On: 22 September 2014, At: 13:54Publisher: Taylor & FrancisInforma Ltd Registered in England and Wales Registered Number: 1072954 Registered office: MortimerHouse, 37-41 Mortimer Street, London W1T 3JH, UKJournal of the Air & Waste ManagementAssociationPublication details, including instructions for authors and subscription ...

  • XC-6000 Automated MercSampler Monitoring System Brochure

    XC-6000 MercSamplerTMSorbent Trap Monitoring SystemCompliance Monitoring Solutions forMercury & Air Toxics Standards (MATS)40 CFR Part 60 and 63MeRCuRy Current XC-6000 System InstallationsWAN PORT10.10.10.50/REMOTE PAUSEDRY CONTACT ALARMPORTXC-6000 MercSamplerTMApex Instruments, Inc.204 Technology Park Lane, Fuquay-Varina, N.C. 27526, U.S.A.800-882-3214 or 919-557-7300Website: www.apexinst.com / ...

  • Exhiniting Company Descriptions- Brochure

    Company |Booth|©Company |Booth|©AADA CArbon SolutionS 821http://www.ada-cs.com303-962-1977ADA Carbon Solutions, LLC is a leading manufacturer of powdered activated carbon (PAC) products that are optimized for mercury removal. Our flagship plant in Red River Louisiana is the largest, most automated and environmentally friendly manufacturing facility in North America focused on products for coal ...

  • Ohio Lumex - Mercury Sorbent Trap Brochure

    C U S T O M I Z E D S O R B E N T T R A P S O L U T I O N S T H A T W O R K F O R Y O U R S O U R C E C O N D I T I O N S . UNIQUE TRAP FEATURES ? Exceptionally low mercury background ? Sorption Capacity up to MILLIONS of ng ? Each trap is individually numbered with High Temperature ink ? “Chain of Custody” ...

  • Mercury 2013 Catalog 1-1-13 NP

    www.apexinst.com919-557-7300 or 800-882-3214Fax: 919-557-7110Website: www.apexinst.comContact: info@apexinst.comApex Instruments, Inc.204 Technology Park LaneFuquay-Varina, N.C. 27526, U.S.A.Mercury & Gas saMplinG cataloGSoftwareXC-8UXC-6000EPCDoug Bernhardt Sales / Customer Servicedbernhardt@apexinst.comMERCURY & GAS SAMPLING EQUIPMENTFLOW, PRESSURE & TEMPERATUREMERCURY AND GAS SAMPLING SYSTEMS ...

  • Air Quality SOQ Brochure

    EDGEWATER COMMONS II ¦ 81 TWO BRIDGES ROAD ¦ FAIRFIELD, NJ 07004 ¦ 973-575-2555 ¦ FAX: 973-575-6617 ¦ www.enviroplan.com ¦ STATEMENT OF QUALIFICATIONS Ambient Air Quality and Meteorological Monitoring Services ...

  • Detailed Catalog of Analytical Services - Brochure

                                             714-895-5494                                          www.calscience.com  ORGANICSANALYSIS  METHOD Fumigants - EDB/DBCP - Low Level  SRL 524M-TCP 1,2,3-Trichloropropane - Low Level  SRL 524M-TCP 1,4-Dioxane - Low Level  SRL 524M-TCP 1,4-Dioxane (Isotope Dilution) - Low Level  EPA 8270C/D(M)   N-Nitrosodimethylamine (NDMA) - Low Level  ...

  • Optima 8x00 ICP-OES Spectrometers Brochure

    Optima 8x00 SeriesICP Optical Emission Spectrometers2ENVIRONMENTALEasy to use and engineered for exceptional throughput and detection limits, the Optima™ 8x00 series helps maximize productivity and profitability.• Dual view capability allows measurement of high and low concentrations in the same run for enhanced productivity• Torch cassette—low maintenance, simple operationGEOCHEMICALDesigned ...

  • EPA Air Monitoring Tools and Techniques Datasheet

    Air Monitoring Tools & Techniques Practical Applications for Savvy Air Investigators Outline Optical Remote Sensing (ORS) Tools: 1) Passive Fourier Transform Infrared (FTIR) 2) Ultraviolet Differential Optical Absorption Spectroscopy (UV-DOAS) 3) Open-Path FTIR (OP-FTIR) 4) Tunable Diode Laser (TDL) 5) Cavity Ring-Down Spectroscopy (CRDS) Readily Available Tools & Techniques 1) Photo-Ionization ...

  • Company Profile Brochure

    CCC OOO MMM PPP AAA NNN YYY    PPP RRR OOO FFF III LLL EEE   COMPANY PROFILE PAGE 2 OF 11 1. Who we are 1.1 Company Legal Information TITLE ENVIROMETRICS Ltd Business Consultants and Engineers LEGAL FORM: LIMITED COMPANY YEAR OF ESTABLISHMENT 2002 VAT NO GR 999913919 ADRESS 20 KAREA STR., 11636, ATHENS, GREECE TELEPHONE +30 210 7230592 F?? +30 210 7230047 ...

  • 2014 Program Guide- Brochure

    2 ©Air Policy & Regulations A. Air Policy & RegulationsB. CEMS & ModelingC. Mercury Multi-Pollutant ControlD. Energy Policy & SecurityE. Renewable EnergyF. Operations & Mgmt G. GHG, Carbon Mgmt & CCSH. Alternative Fuel TechnologiesI. Sustainability & WaterJ. Energy Efficiency & Mgmt.CEMS &ModelingMercury Multi-Pollutant ControlEnergy Policy & Security Renewable EnergyOperations & MgmtGHG, ...

  • Premium

    Metrohm - Model 797 VA - Computrace Instrument for Voltammetry Stand for Trace Analysis System - Brochure

    The all-round instrument for voltammetry797 VA Computrace797 VA Computrace in brief02 The 797 VA Computrace is a modern voltammetric meas-uring stand that is connected to a PC via a USB port. The PC software provided controls the measurement, records the measuring data and evaluates it. Due to the well-laid-out program structure operation is very easy. All the methods described in the Metrohm ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you