current flow meter Downloads

  • A.YITE - Model GE-104P - Portable Handheld Flow Current Velocity Meter User Manual

    A.YITE TECHNOLOGY GROUP http://www.ayite.net http://www.ayite1973.com Email: sales@ayite.net GE-104A Portable Current Meter User Manual A.YITE TECHNOLOGY GROUP A.YITE TECHNOLOGY GROUP http://www.ayite.net http://www.ayite1973.com Email: sales@ayite.net GE-104P-A portable current meter GE-104PA ...

  • Premium

    Model C31 - Universal Current Meter - Operating Instructions Manual

    EnglishOperating InstructionsUniversal Current Meter C31We reserve the right to make technical changes34III. Rinse the current meter after every application in clear water and dry it carefully. Store it in the designated wooden box at a dry storage place. In order to avoid corrosion, do not store the current meter in the adjacency of lead batteries.OTT Hydromet GmbHLudwigstrasse 1687437 Kempten ...

  • Insertion Mass Flow Meters (Single Point)- Brochure

    IComplex Technology Made SimpleThe  Kurz WGF  single-point  insertion  flow meter  for wet  gas  environmentsincludes  the  qualities  and  features  found  in  all  Kurz  constant  temperaturethermal flow meters that make them outperform all other currently availablethermal mass flow meters, including:• ...

  • Hydro-Logic - Gauger2 - Analysis Rating Development System Brochure

    Gauger2 benefitsWhat is Gauger2?Gauger2 Current-meter gauging systems Components of Gauger2Gauger2 is a low cost suite of three software packages designed to capture, store and analyse current-meter discharge measurements taken in rivers and other open channels. Eachpackage can be operated independently or as an integratedcurrent-meter gauging and rating analysis system.Gauger2 can also be fully ...

  • Data Sheet KKV Dosing System

    seraKKV - Dosing systemSeybert & Rahierwith automatic monitoringApplicationsera - KKV - Dosing systemswith automatic monitoring consistof single diaphragm pumps – made of high-quality materialsand easy to maintain – combined with an automatic monitoringsystem.Advantages? Leakage-free? Constant dosing accuracy? Safe to run dry? Long service life? Permanent monitoringand automatic adjustmentof the ...

  • Hydro-Logic - Gauger2 - Desktop Current-Meter Gauging Database Brochure

    What is Gauger2?Streamflow gauging systems for riverbank and desktop analysisGauger2 is a low cost suite of three software packages designed to capture, store and analyse current-meter discharge measurements taken in rivers and other open channels. Each package can be operated independently or as an integrated current-meter gauging and rating analysis system.Gauger2 can also be fully integrated ...

  • UFM 800 W + C Datasheet (PDF 753 KB)

    MAR© KROHNE 12/2006 7.02343.22.00UFM 800 W, Cand UFM 800 W Hot TappingUltrasonic flowmeterfor water and wastewater.. .with weld-in sensors for metal pipelines. . .with built-on or built-in sensors for open channelsVariable area flowmetersVortex flowmetersFlow controllersElectromagnetic flowmetersUltrasonic flowmetersMass flowmetersLevel measuring instrumentsCommunications technologyEngineering ...

  • QH SERVIS - Brochure

    QH SERVIS, spol. s r.o. Piv ov arská 274, CZ - 686 01 Uherské Hradi?te tel:+420 572 545 646 fax:+420 572 545 931 e-mail: INFO@QHSERVIS.CZ WWW.QHSERVIS.CZ QH SERVIS We REPAIR SAMPLERS manufactured by EDMUND BÜHLER, EPIC , MONTEC and others. We do warranty and post warranty serv icing of our samplers. We hav e long experience in POST-WARRANTY SERVICING of EPIC, XIAN, XANTOS, ...

  • Universal Current Meter Brochure

    NewModelCM-32Universal Current MeterThe AKIM Universal Current Meter CM-32 is a measuring instrument to determine the flow velocity of water in open canals, rivers, streams, rivulets, pressure pipes, lakes, and the sea. For measuring flow velocities from 0,025 m/sec. to 12 m/sec. High accuracy Low starting speed of 0,025 m/sec. Application of absolutely and anti-corrosive materials. Made of ...

  • ML 840 Manual Brochure

    Microlink 840User ManualManual Code: ML840-1.0Issue Date: October 2011Information in this manual is subject to change without notice. Updates are listed on our website at http://www.microlink.co.uk/techsupp.html© Biodata Limited, 201110 Stocks StreetManchesterM8 8QGUKTel: 0161–834 6688Fax: 0161–833 2198E-mail: sales@microlink.co.ukhttp://www.microlink.co.uk/E-mail: ...

  • Model Nor-Mag Series - Electromagnetic Flow Meters Brochure

    Perfecting MeasurementPerfecting Measurement www.hofferflow.com PREMIER GAS SERIES TURBINE PREMIER GAS SERIES TURBINE FLOWMETERS BY HOFFERFLOWMETERS BY HOFFER HO-PG-100B Think about it... If you could buy a proven gas flowmeter that costs less, has longer life, and better performance than ANY meter on the Market, would you? Turn the page to find out why you should. Benefits: Hoffer ...

  • QTRACE-Discharge Measuring System Brochure

    Product CertificateQTRACE - Discharge Measuring SystemQTRACE Discharge Measurements by the Salt Tracer Dilution Method?Logotronic GmbH Page 1 of 8Product CertificateQTRACE - Discharge Measuring SystemGeneralTwo methods are commonly used for routine discharge measurements on surface water:? Current meters? Dilution gaugingFor dilution gauging we offer our measuring system QTRACE. This system was ...

  • The Differences Between the Willowstick Method and DC Resistivity Brochure

    1 THE DIFFERENCES BETWEEN THE WILLOWSTICK METHOD AND DC RESISTIVITY 2 The Differences between the Willowstick Method and DC Resistivity The Willowstick method is an imaging technology designed for mapping groundwater. It is quite different from DC Resistivity technologies such as Electrical Resistivity Tomography (ERT), High Resolution Resistivity, and Electrical Resistivity Imaging ...

  • Logotronic - QTRACE Brochure

    Product Certificate QTRACE - Discharge Measuring System QTRACE Discharge Measurements by the Salt Tracer Dilution Method ?Logotronic GmbH Page 1 of 8 Product Certificate QTRACE - Discharge Measuring System General Two methods are commonly used for routine discharge measurements on surface water: ? Current meters ? Dilution gauging For dilution gauging we offer our measuring system ...

  • Small Current Meter Brochure

    NewModelThe AKIM MCM-02 Small Current Meter is used for measuring the flow velocity at low water levels, e.g. in: Small Rivers Small canals Streams Lakes and seas Pressure pipes, falajs Natural water courses LaboratoriesSmall Current Meter is used worldwide for its proved quality, precision and reliability in measuring low water levels. It is especially recommended for measure-ments in remote ...

  • Kurz - Model 454FTB-WGF - Single-Point Insertion Flow Meter Technical Specifications Brochure

    IComplex Technology Made SimpleThe  Kurz WGF  single-point  insertion  flow meter  for wet  gas  environmentsincludes  the  qualities  and  features  found  in  all  Kurz  constant  temperaturethermal flow meters that make them outperform all other currently availablethermal mass flow meters, including:• ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you