drain stopper Downloads

  • Pipe Stoppers and Bracing Kits- Brochure

    ®®BECKKanal- und SchachtgeräteKanal- und SchachtgeräteSchachtregulierungenSchachtregulierungenSEITÜBER 25 JAHRENDEUTSCHLANDSNR.125BECKKanal- und SchachtgeräteKanal- und SchachtgeräteSchachtregulierungenSchachtregulierungenBlocking, testing orrelocating in pipesand shaftsPipe stoppersPipe test equipmentBracing kit•Other products:Manhole cover lifting equipmentShaft safety gratingsAnti-clatter ...


    By Beck GmbH

  • Pave Drain Combining Paving and Linear Drainage Brochure

    Grey YorkstoneSilver Grey Mid Grey GraniteBuff Silver Grey GraniteColoursPrecise colour and surface texture should be judged from actual materials rather than photographic representations.www.marshalls.co.uk/watermanagementSales Office: 0845 3020400Technical and Design Team: 0845 3020606Email: designteam@marshalls.co.uk Manufacturing Standards: see page 19WMSD05 Paving. . . . . . . . . . . . . . ...


    By Marshalls Water Management

  • Premium

    Supel™ Tox OchraBind Data Sheet

    Supel™ Tox OchraBind cartridges provide cleanup of whole grain and feed samples for the detection of Ochratoxin A prior to use in HPLC, GC, and other analysis ...

  • Premium

    Supel™ Tox FumoniBind Data Sheet

    Supel™ Tox FumoniBind cartridges provide rapid cleanup of whole grains and cereals for the detection of fumonisins (B1 and B2) prior to use in HPLC analysis ...

  • Premium

    Supel™ Tox TrichoBind SPE Cartridge - Data Sheet

    Supel™ Tox TrichoBind cartridges provide cleanup of whole grains, feeds, and other complex matrices for the detection of Type A and B trichothecenes prior to use in HPLC, GC, and other analysis ...

  • Premium

    KjelFlex K-360 Steam Distillation - Technical Datasheet

    Modular distillation unit for a wide range of applications requiring steam distillation. The instrument can be configured to fulfill various requirements and can be upgraded if needs ...


    By BÜCHI Labortechnik AG

  • Premium

    Hydro/ 2 and Hydro/ 3 - Motor Metering Pumps Operating Instructions - Manual

    Metering pumpsHydro/ 2 and Hydro/ 3Operating instructionsP_HY_0004_SWENOriginal Operating Instructions (2006/42/EC)984721 BA HY 017 10/15 ENPlease carefully read these operating instructions before use. · Do not discard.The operator shall be liable for any damage caused by installation or operating errors.The latest version of the operating instructions are available on our homepage.Read the ...

  • Premium

    Original Glass-Ware Brochure

    1OriginalGlasswareSafety, precision and durability you can rely on 2Büchi QualityCriteriaHigh-quality glass:Inert industrial glass (borosilicate 3.3, ISO/DIN 3585), resistant to chemicals, little dulling from con-tact with acids and alkalis.Generous wall thickness:Uniform thick-ness, also at the base, hence fewer breakages.Tension-relieved at 540°C:Highly shock resistant, no internal tensions, ...


    By BÜCHI Labortechnik AG

  • Premium

    BUCHI Original Glassware- Brochure

    1Original GlasswareSafety precision and durability you rely onContentsRotavapor® 5Evaporating Flask 5Vapour Ducts 7Receiving Flask 10Beaker Flask 10Distillation Spider 11Small Components 12Spare parts for Rotavapor® R-210/215 14Spare parts for Rotavapor® R-200/205 16Spare parts for Rotavapor® 18Rotavapor® R–200 / R–205 20Special Assembly 22Syncore® 23Multivapor™ 24Rotavapor® 2520/50/100 liters ...


    By BÜCHI Labortechnik AG

  • Premium

    Extraction Solutions - Brochure

    Total fat determination with an authentic and accelerated Soxhlet. You look for an automated way to determine the total fat content in compliance with standardized methods. We provide a fully compliant, exhaustive extraction solution with excellent reproducibility according to Weibull-Stoldt, i.e. acid hydrolysis followed by Soxhlet ...


    By BÜCHI Labortechnik AG

  • Premium

    Precast Concrete Sludge Storage Tank Specifications

    Precast concrete storage tank with precast concrete roof, beams, columns, posts, and walls; cast-in-place reinforced concrete floor and foundations; access hatches, pressure relief valves, decant chambers, wall castings and waterproofing, separate compartments as specified herein , and as needed for a complete and workable ...


    By WeDoTanks.com LLC

  • ASP CAMSTOPPER® Brochure

    ASP CAMSTOPPER patent is the property of NORHAM SAS - www.norham.frASP CAMSTOPPER®Products range : Drain StoppersMECHANICAL SEWER PLUGSBENEFITS :The safest stopper ever designed20 times quicker to install and retrieveNon man-entry retrievalLonger lasting durable sealQuality EPDMPLASTIC MOULDING INJECTIONDRAIN STOPPERSThe New Range from 2010"Cam" RangeNORHAM PLASTICS reserves the right to modify. ...


    By Norham Plastics Limited

  • Supel™ Tox OchraBind Data Sheet

    Supel Tox OchraBindCat. No. 55318-UT712122©2012 Sigma-Aldrich Co.SUPELCOBellefonte, PAThis Data Sheet Contains Important Information About The Product.DescriptionSupel™ Tox OchraBind cartridges provide cleanup of whole grain and feed samples for the detection of Ochratoxin A prior to use in HPLC, GC, and other analysis methods.ProcedureI. Sample Extraction (Use methylene chloride resistant ...


    By MilliporeSigma

  • LyoAlfa Brochure

    Av. Font i Sagué, 55Parc Científic i Tecnològic Orbital 4008227 Terrassa (Spain)T +34 937 361 600F +34 937 861 380www.telstar-lifesciences.comLyoAlfa 10/15Laboratory Freeze-dryerACCESSORY UNITS DIMENSIONSChamberDimensions chamber with isolation valve mm Ø 400 x 480Dimensions stoppering chamber with isolation valve mm Ø 400 x 645Product tray dimensions mm Ø 300Clearance between shelves mm 702Total ...


    By Telstar Technologies

  • Type 15 Thermoplastic Diaphragm Valves – Manual

    ASAHI AV VALVES Installation,Operation and Maintenance ManualDiaphragm Valves Type 15Serial No. H – V031 E – 3 Diaphragm Valves Type 15User’s Manual Contents(1) General operating instructions(2) General instructions for transportation,unpacking and storage(3) Name of parts(4) Comparison between workingtemperature and pressure(5) ...


    By Asahi/America, Inc.

  • Standard Hydrant- Brochure

    Figure 3Figure 2Shut O? Valve Leak Check:6.) If no leaks are detected then replace back?ow preventer and proceed to back ?ll hydrant with soil.SEAL, O-RING21O17OOO2Figure 4Remove back?ow preventer at quick disconnect (Figure 2) Operate hydrant at partial ?ow with thumb over outlet until the water pressure forces past thumb. (Figure 3). At this point shut o? hydrant. [ With hydrant full of ...


    By Hoeptner Perfected Products

  • Premium

    Piston Metering Pump Sigma/ 2 Control Type SCKa Operating Instructions - Manual

    A qualified employee is deemed to be a person who is able to assess the tasks assigned to him and recognise possible dangers based on his/her technical training, knowledge and experience, as well as knowledge of pertinent ...

  • Self Closing Hydrant- Brochure

    Figure 3Figure 2Shut O? Valve Leak Check:6.) If no leaks are detected then replace back?ow preventer and proceed to back ?ll hydrant with soil.SEAL, O-RING21O17OOO2Figure 4Remove back?ow preventer at quick disconnect (Figure 2) Operate hydrant at partial ?ow with thumb over outlet until the water pressure forces past thumb. (Figure 3). At this point shut o? hydrant. [ With hydrant full of ...


    By Hoeptner Perfected Products

  • Standard ADA Hydrant- Brochure

    Figure 2 Figure 3SEAL, O-RING21O17OOO2Figure 4GROUNDLEVELBURYDEPTH 27”FROST LINEFigure 11.) 2.)Hydrant canister must be placed below existing frost line. Fig.13.)4.)No ground preparation is required for the Freeze Flow Sanitary Yard Hydrant; therefore it can be placed in any soil condition. Hydrant canister is stainless steel and pipes are all galvanized steel, which meet ASTM specs. It is the ...


    By Hoeptner Perfected Products

  • Roof Hydrant- Brochure

    SUGGESTED INSTALLATION 1ROOF2 ft FLASHING1ftROOFSUPPORT PIPE CLAMPS (2)SUGGESTED INSTALLATION 22 ft FLASHING1ftROOFSUPPORTPIPE CLAMPS (2)ROOF1.) Remove Head, handle and operating rod as one peice.2.) Insert Roof Hydrant through roof opening.3.) Reassemble head making sure handle is in full open position.1.1.) 2.) Hydrant’s stainless steel canister must be securely located below the roof. Two ...


    By Hoeptner Perfected Products

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you