  • Model SPR-IDA - Reagent for Preconcentration/ Matrix Elimination Brochure

    SPR-IDAReagent for Preconcentration/ Matrix EliminationSPR-IDA (Suspended Particulate Reagent – Iminodiacetate) is a sample preparation material for preconcentration of trace elements and reduction of high alkali metal (e.g. Na) sample matrix levels. The reagent consists of 10 micron diameter polymer beads that have been chemically derivatized with the iminodiacetate chelating agent. Small ...

  • Atomic Fluorescence Spectrophotometer Brochure

    HPLC-VG-AFS AFS Beijing Beifen-Ruili Analytial Instrument (Group) Co. Ltd. Bldg. A5, No.9 Jiuxianqiao East Rd. Chaoyang District, Beijing 100015, P. R. China Tel: 86 10 84347289, Fax: 86 10 64377039 Email: international@bfrl.com.cn AF-610D2 HPLC-VG-AFS Speciation Analyzer  z Low cost and perfect performance for speciation and total amount analysis of heavy metal elements, ...

  • Direct Determination of Trace Elements in Urine using the aurora M90 ICP-MS

    IntroductionInductively Coupled Plasma Mass Spectrometry offers low detection limits, multi-element capabilities, simplified sample preparation and low sample consumption. It is very useful for the determination of trace and ultra-trace elements in various biological samples.The aurora M90 ICP-MS is equipped with Bruker’s patented 90 degree ion mirror ion optics [1] and Collision Reaction ...

  • AA3003 Determination of Major Components and Trace Contaminants in Assorted Plating Baths by Atomic Absorption Analysis - Application Notes

    SIC: 3471Determination of Major Components andTrace Contaminants in Assorted PlatingBaths by Atomic Absorption AnalysisPrecious metal, non-ferrous, and ferrousplating operations cover almost every facetof modern life: automotive parts, kitchen &bathroom fixtures, electrical parts, electroniccomponents, furniture, tools, plumbing,construction supplies, die castings, jewelry,etc.Good manufacturing ...

  • AA3006 Determination of Major Electrolytes, Minor Minerals, and Trace Heavy Metals in Physiological Fluids by Flame and Graphite Furnace Atomic Absorption Spectroscopy - Application Notes

    SIC: 8071Determination of Major Electrolytes, MinorMinerals, and Trace Heavy Metals inPhysiological Fluids by Flame and GraphiteFurnace Atomic Absorption SpectroscopyAccurate measurements of specific metalsin various biological systems is extremelyimportant. These metals can be classified intoseveral groups: the high level major electrolytes(Na, K, Ca, Mg), which are crucial to normalprimary ...

  • Determination of Trace Metals in > 99.999% Gold using the aurora M90 ICP-MS

    IntroductionThe strong demand for gold in recent times has seen the metal’s market value grow to levels not encountered since the early 1980s. Although the jewelry industry still makes up for the majority of the world’s total demand for gold, one area that has seen significant growth is its use in electronics, particularly within telecommunications, information technology, and safety critical ...

  • Labocon Atomic Fluorescence Spectrophotometer Catalogue

    NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.www.labocon.com2 www.labocon.com2 www.labocon.comATOMIC FLUORESCENCE SPECTROPHOTOMETERATOMIC FLUORESCENCE SPECTROPHOTOMETER LAFS-100 SERIESFeaturesLabocon Atomic Fluorescence Spectrophotometer LAFS-100 Series offer elemental analysis of hydride forming element.The Hydride/vapor ...

  • Premium

    Bench Top Spectrometer - Brochure

    Non-destructive elemental analysis C(6)-Fm(100) from Sub- PPM to 100% concentrations Six customizable filters for fast and accurate determination of trace and minor elements Down to 123eV resolution Robust design, compact geometry Sample tray with 8/16 positions Easy to operate due to the proprietary nEXt™ software package Silicon Drift Detector (SDD) enables extremely high count rate ...

  • EzPrep - Preparative Fraction Collector Brochure

    Atomic Emission DetectorSensitive Universal and Selective Element Detection for Routine and Research AnalysesS I M P LY S M A R T S O L U T I O N S1Se196 198 200 202 204 206Wavelength (nm)4 6 108 1412 1816 2220 24Time (minutes)4 6 108 1412 1816 2220 24Time (minutes)4 6 108 1412 1816 2220 24Time (minutes)Sophisticated Multielement Detection moves from the Research to the Routine LaboratoryThe ...

  • Premium

    Trace Metals Analysis in High Purity Gold Using PlasmaQuant MS Elite - Special Application Note

    1. IntroductIon Within the last decades, the demand and production of gold are continuously growing. The biggest demand is in the manufacturing of jewellery with a share of about 50%. Furthermore, about 10 % of the yearly mined gold is used for manifold applications in the industry. Thanks to its peculiar properties like corrosion, chemical resistance, electrical conductivity and ductility, gold ...

  • Multiresidue pesticide screening by LC-ESI-TOF MS

    Titelmasterformat durchKlicken bearbeiten• Textmasterformate durchKlicken bearbeiten• Zweite Ebene• Dritte Ebene• Vierte Ebene• Fünfte Ebene1Multiresidue pesticide screening by LC-ESI-TOF MSChristian Neusüß, Petra Decker, Matthias Pelzing, Arnd Ingendoh, Andre WetterBruker Daltonik GmbH, Fahrenheitstr. 4, 28359 BremenIntroductionThe usefulness of LC/MS/MS for the unambiguous identification and ...

  • Premium

    PlasmaQuant MS - Special Application Note Brochure

    1. IntroductIon Fresh drinking water is needed for life as well as being a valuable source of vital minerals for health. Water for consumption is sourced from various resources including surface fresh waters, ground water and even seawater. The source often dictates the level of pre-treatment required before it is considered safe for consumption. While groundwater is naturally filtered and may ...

  • Premium

    Monitoring Drinking Water Quality with the PlasmaQuant® MS - Special Application Note

    1. IntroductIon Fresh drinking water is needed for life as well as being a valuable source of vital minerals for health. Water for consumption is sourced from various resources including surface fresh waters, ground water and even seawater. The source often dictates the level of pre-treatment required before it is considered safe for consumption. While groundwater is naturally filtered and may ...

  • AA3011 Evaluation of Mineral Supplements for Content and Purity by Flame/Graphite Furnace AAS - Application Notes

    SIC: 074, 20, 283, 512Evaluation of Mineral Supplementsfor Content and Purity byFlame/Graphite Furnace AASDoctors, dieticians and health officialsrecommend a balanced diet that providesessential minerals for proper nutrition in thehuman body. The accurate analysis of metalsin vitamin/mineral preparations and foodsupplements is very important. These metalscan be classified into several groups - ...

  • Online Analyser for Zinc Brochure

    Continuous Analysis. Reliable Results. COMPOSER Johann G.Albrechtsberger - SEIBOLD Online-Analyser for Zinc Sources Zinc is an essential trace element found in virtually all food and potable water in the form of salts or organic complexes. Natural sources. Zinc species are predominantly determined in the aquatic environment and in soils and sediments. Industry. Zinc is used principally ...

  • Use of the SPR-IDA Reagent for the Determination of Trace Metals in a Coastal Seawater Reference Material Application Note

    14306 Industrial Road Omaha, NE 68144 USA PHONE 402.733.2829 FAX 402.733.5292 WWW CETAC.com Application Note © 2014 Teledyne Technologies, Inc. APPLICATION NOTE: SPR-IDA-001 Use of the SPR-IDA Reagent for the Determination of Trace Metals in a Coastal Seawater Reference Material Dr. Fred Smith, Paula DoeschotThe direct introduction of seawater to an Inductively Cou-pled Plasma Mass ...

  • DFE Rated Filter Element Brochure

    DFE . . . The Evolution in Filter Element Multi-Pass Development Testing Hy-Pro’s Competitive Advantage www.filterelement.com 9 What is DFE (Dynamic Filter Efficiency)? All hydraulic and lube systems have a critical contamination tolerance level that is often defined by, but not limited to, the most sensitive system component such as servo valves or high speed journal bearings. Component ...

  • HyPro - Model DFE - Rated Filter Element Upgrades Brochure

    DFE . . . The Evolution in Filter Element Multi-Pass Development Testing Hy-Pro’s Competitive Advantage www.filterelement.com 9 What is DFE (Dynamic Filter Efficiency)? All hydraulic and lube systems have a critical contamination tolerance level that is often defined by, but not limited to, the most sensitive system component such as servo valves or high speed journal bearings. Component ...

  • Premium

    Analysis of Low Le vel Beryllium in Urine Using the PlasmaQuant MS - Special Application Note

    1. IntroductIon Elemental beryllium is a steel gray appearing alkaline earth metal with properties like brittleness and high rigidity being the lightest among metals. The majority of beryllium is found in minerals and soils rather than in its elemental form. Beryllium is found in about 30 different mineral species like different compounds including aluminium e.g. Beryl (beryllium aluminium ...

  • Principles and performance of the Collision Reaction Interface for the aurora M90

    Bruker’s patented 90 degree ion optics provides unsurpassed efficiency of transfer of ions from the interface to the mass analyzer, which enables the aurora M90 ICP-MS to achieve a sensitivity of more than 1000 million c/s per mg/L of analyte, while maintaining oxide ratios (CeO+/Ce+) below 3%. The aurora M90 ICP-MS is also equipped with Bruker’s unique and patented interference management ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you