The RJD-150 emergency chlorine scrubber is the next generation in emergency chlorine scrubber technology. It uses a new high ca-pacity, non-hazardous dry adsorbent media to absorb up to 150 lbs (70 kg) of chlorine vapor, at leak rates up to 78 lbs/min as required by the Uniform Fire Code. The RJD-150 system is designed to maintain negative pressure in the chlorination and chlorine storage rooms, ...
The RJD-2000 emergency chlorine scrubber is the next generation in emergency chlorine scrubber technology. It uses a new high capacity, non-hazardous dry adsorbent media to absorb up to 1-Ton of chlorine vapor, at leak rates up to 78 lbs/min as required by the Uniform Fire Code. The RJD-2000 system is designed to maintain negative pressure in the chlorination and chlorine storage rooms, while ...
EMERGENCY KIT "B"CHLORINE INSTITUTEFOR ONE TON CHLORINE CONTAINERSThe Chlorine Institute Emergency Kit "B" is manufactured to the design specifications of the Chlorine Institute.The Emergency Kit "B" contains devices to stop leaks at the valves, fusible plugs, and in the side wall of chlorine one toncontainers which conform to specification DOT 106A500X. Two instruction booklets explaining the ...
FOR 100-150 lb. CHLORINE CYLINDERSThe Chlorine Institute Emergency Kit "A" is manufactured to the design specifications of the ChlorineInstitute. The Emergency Kit "A" contains devices to stop leaks at the valve, fusible plug, and in the side wallsof chlorine 100 & 150 lb. cylinders which conform to specification DOT 3A480. Two instruction bookletsexplaining the application of each device are ...
The EVS-150 emergency chlorine scrubber is a multi-stage wet scrubber system designed to treat chlorine vapors from a bank of 150lb (70kg) chlorine cylinders, at leak rates of 28 lbs/min or more, exceeding the requirement of the Uniform Fire Code. The EVS-150 system is designed to maintain negative pressure in the chlorination and chlorine storage rooms, while limiting the atmospheric release of ...
C-376AM EMERGENCY REPAIR KIT "A" FOR 100/150 LB. CYLINDERS OF ANHYDROUS AMMONIA INTRODUCTION The Chlorine Specialties Emergency Repair Kit "C-376AM" is manufactured for use with the standard US DOT #3A480 Cylinder of 100 or 150 pound capacity. These cylinders have outside diameters between 8¼ and 10¾ inches and overall height from 39½ to 59 inches. All kits are manufactured totally by ...
Safetysorb™ Chlorine Adsorbent Media Description: Safetysorb™ adsorbent media is specifically designed to meet the requirements of a chlorine release emergency. This media remains available for adsorption until the event of an emergency release. When this occurs gaseous chlorine can be evacuated from the affected area and passed through a bed of Safetysorb™. Safetysorb™ will react with the ...
EMERGENCY KIT "C”CHLORINE INSTITUTEFOR CHLORINE TANK CARS AND TANK TRUCKSEMERGENCY KIT "A" FEATURES:Device #6Device #24:: containment device designed to contain leaks in and around the angle valves. Device #6 includestwo gaskets molded of Viton to conform to the bottom of hood 6A.containment device designed to contain leaks in and around the pressure relief device. Device#24 includes a ...
Bulletin 252.12 Bulletin 252.12 Page 1/2 6/1/13 Specification 17961 Sky Park Circle, Ste. A. Irvine, CA. 92614 Emergency Shutoff System Series CR-1Y (Duplex) – Model II for Chlorine Cylinder and Ton Container Automatic Switchover Systems 1. Scope This specification describes the Series CR-1Y Emergency Shutoff System for Chlorine Cylinder and Ton container Valves as manufactured by Halogen ...
M E D I A S P E C I F I C AT I O NChlorosorb® Ultra carbon-based media shallconsist of manufactured, generally spherical,porous pellets measuring 1/8” in diameter.Pellets shall be formed from a combination ofpowdered activated carbon, alumina and otherbinders, suitably impregnated to enhance thecapacity for removal of chlorine.Impregnants shall be applied during pellet for-mation, such that the ...
Bulletin 252.14 Bulletin 252.14 Page 1/2 1/1/05 Specification 17961 Sky Park Circle, Ste. A. Irvine, CA. 92614Emergency Shut Off System Series CR-1Y (Hexacon) - Model II for Chlorine Cylinder and Ton Container Automatic Switchover Systems 1. Scope This specification describes the Series CR-1Y Emergency Shut off System as manufactured by Halogen Valve Systems, Inc. for Chlorine Cylinder and Ton ...
CLEAN WATER PUMPING SERVICESINSTALLATION • SERVICE • REPAIRNational SupportTel: 01630 647200TROUBLE FREE COST EFFECTIVE SERVICEClean Water Pumping ServicesT-T is amongst the UK leaders in the pumping industry, offering a wholly separate comprehensive service for clean water systems, domestic, commercial and industrial. With our dedicated service teams, knowledge and capabilities we can provide ...