exhaust gas dilution sampling probe Downloads

  • Dekati® FPS: Fine Particle Sampler Brochure

    Dekati® FPS-4000Fine ParticleSamplerAutomotive exhaustand combustionaerosol dilutionVersatile samplingsystemReal-time dilutioncondition controlExcellence in Particle MeasurementsDekati® Fine Particle Sampler is a guaranteed solutionfor diluting and conditioning aerosol and gaseous samplesfor measurement instruments. The two stage dilutionsystem features unmatched versatility with ...

  • Premium

    Sierra - Model BG-3 Particulate Partial Flow Sampling System - Datasheet

    TECHNICAL DATA SHEET? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ?Particulate Partial Flow Sampling SystemThe Model BG-3 with TDAC (Transient Dilution Airflow Control) system is a Particulate Partial Flow Sampling System (PPFSS) that provides accurate, repeatable Particulate Matter (PM) measurements for transient and steady-state engine and vehicle testing. More than three years of research, development and ...

  • Premium

    Sierra - Model 628S - Engine Intake Air Flowmeters - Air-Trak - Technical Datasheet

    TECHNICAL DATA SHEETParticulate Partial Flow Sampling SystemThe Model BG-3 with TDAC (Transient Dilution Airflow Control) system is a Particulate Partial Flow Sampling System (PPFSS) that provides accurate, repeatable Particulate Matter (PM) measurements for transient and steady-state engine and vehicle testing. More than three years of research, development and testing at Southwest Research ...

  • CFC Abatement Monitoring Inlet and Outlet Solutions

    APPLICATION DATASHEET: atmosFIRCall us on: +44(0)1270 872 000www.protea.ltd.ukProtea Limited. 101 The Courtyard, Radway Green Venture Park, Radway Green, Crewe, Cheshire, CW2 5PR.in measurement solutionstechnology leadershipProteaAD-141 : May 2015The FTIR analyser is a full-spectrum analytical device that enables the whole Mid-IR spectrum to be detected in a single instrument. atmosFIR can be ...

  • Engine Emission Measurement Solutions Brochure

    Dekati® SolutionsEngine Emissions• After-treatment device and engine development• On-board measurements• Blow-by gas emissions• EURO5b regulatory measurementsExcellence in Particle MeasurementsDekati® SolutionsEngine emissionsParticle emissions from engines vary a lot depending on the type of engine and fuel used. Additional factors including engine load, ECU operation and environmental ...

  • Measurement Solution for CFC Abatement Control via Two Stream FTIR System - Application Datasheet

    APPLICATION DATASHEET: atmosFIRCall us on: +44(0)1270 872 000www.protea.ltd.ukProtea Limited. 101 The Courtyard, Radway Green Venture Park, Radway Green, Crewe, Cheshire, CW2 5PR.in measurement solutionstechnology leadershipProteaAD-141 : May 2015The FTIR analyser is a full-spectrum analytical device that enables the whole Mid-IR spectrum to be detected in a single instrument. atmosFIR can be ...

  • Instrumatic CEMS

    www.instrumatic.comComplies with U.S. EPA requirements, 40 CFR part 60/75Dilution CEM System for Combustion Plants and MARPOL Annex VIinstrumatic a/sTechnical Speci?cationsDimensions (D × W × H) 800 × 600 × 1800 mm Weight Approximately 200kgPower supply 115/230 VAC 50/60 HzAir supply Clean oil-free com pressed air non-con densing, pressure 6–8 bar, consumption 20 ...

  • Premium

    EGAS-FT Turnkey Monitoring System Brochure

    www.environnement-sa.comEngine Exhaust Gas Analysis Systems EGASEXCLUSIVE FEATURES:Sampling: Sampling system (filter and line) heated and thermoregulated (191°C) Sampling achieved by the heated pump, the heated gas is then flushed back into the FTIR cell in ''over flow'' thus allowing a constant and continuous pressure and flow in the cell. Sampling probe with heated filter (2 µm) integrated ...

    By ENVEA

  • Testo - 350 - Portable Emission Analyzer Brochure

    testo 350. For emission testingand combustion analysis.PortableEmissionAnalyzer2The testo 350 is built with rugged cam-lock connections and a simple USB interface.Control Unit Docked or remote operation via Bluetooth (up to 300 feet) or wired (up to 3,000 feet).Analyzer Box Superior rugged construction.Whether you are testing for compliance or troubleshooting and tuning your combustion process, ...

  • Semtech - Model Ecostar Plus - Gaseous and Flow Measurement - Brochure

    SEMTECH® ECOSTARMobile Test Bench(FuLLy 1065 COMPlIANT)Building on over forty years of experience in gas and exhaust flow measurement and as the world’s pre-eminent PEMS equipment supplier, Sensors has developed the all new SEMTECH ECOSTAR product line. This rugged, compact and portable suite of gaseous and particulate measurement devices meets world-wide laboratory grade performance ...

  • Premium

    EGAS 2M Engine Exhaust Gas Analysis System Brochure

    EGAS 2MEGAS 2MMultigas analysis cabinet (control unit)Mobile sample handling systemGRAPHITE 52MMIR 2MTOPAZE 32M Main applications• Engine manufacturers and testing companies in the automotive, heavy duty, aviation, marine, rail transport sectors, etc.• Certification Bodies,• Universities and Research Centres,• General engine and/or vehicle performance test,• Development of clean engines,• ...

    By ENVEA

  • Testo - Model 340 4 - Portable Gas Combustion Analyzer Brochure

    testo 340 Speed, power & precision in industrial combustion analysis.testo 3402Optimizing the combustion process and increasing fuel effi ciency are necessary to compete in today’s market. The testo 340 is the ideal tool to con? rm proper set-up and to identify emission problems before they get serious.The Ultimate Portable Combustion Tuner• 4-gas ? exibility in a rugged, compact handheld ...

  • Clenbuterol in Equine Plasma – A Study of Superior Ion Source Robustness & High Sensitivity on a New EVOQ™ Model LC Triple Quadrupole Mass Spectrometer

    Application Note #704055Clenbuterol in Equine Plasma – A Study of Superior Ion Source Robustness & High Sensitivity on a New EVOQ™ Model LC Triple Quadrupole Mass SpectrometerBruker Daltonics is continually improving its products and reserves the right to change specifications without notice. © Bruker Daltonics 11-2012, #704055Abstract This application note demonstrates the sustained high ...

  • Gas Detection and Analysis Brochure

    Gas Detection & AnalysisGastec Detector Tube SystemPortable Gas DetectorsFixed Gas Monitoring SystemsService & SupportGAS DETECTION & ANALYSISa1-cbiss have over 20 years experience in the gas detection market. a1-cbiss pride themselves on placing great emphasis on customer service and support, which can only benefit customers. a1-cbiss know the importance of fast delivery times and have ...

  • Environmental Monitoring Products Catalogue

    .Environmental Monitoring Pricelist Environmental Monitoring Products Updated 01/07/20010 Mint Bridge Road Kendal Cumbria Tel: 01539 727878 Email:sales@environmonitoring.co.uk www.environmonitoring.co.uk Index section 1. Gas Sample Probes 2. M&C Gas sampling probes 3. Heated lines and temperature conrollers 4. Gas conditioner – Millennium, M&C 5. Isokinetic samplers & ...

  • Questron Technologies Corporation - Company Brochure

    Sample Prep Technologyfor Scienceand the EnvironmentQuestron Technologies Corp.Chemistry – With PrecisionQuestron Technologies Corp.Nestled in the midst of Canadian manufacturing heartland in the Toronto area in the province of Ontario, Questron is dedicated to the intelligent implementation of microwave technology for science and the environment.Since its first beginnings, Questron has been a ...

  • Enerac - Model 700 - Integrated Emissions System Instruction Manual

    1 INSTRUCTION MANUAL INTEGRATED EMISSIONS SYSTEM MODEL 700MODEL 700MODEL 700MODEL 700 ENERAC, INC 67 BOND ST. WESTBURY,NY. 11590 (800) 695(800) 695(800) 695(800) 695----3637363736373637 FAX (516) 997FAX (516) 997FAX (516) 997FAX (516) 997----2129212921292129 2 3 TABLE OF CONTENTS LIST OF ABBREVIATIONS.......................................... 4 ...

  • Premium

    TOCII - Model CA72TOC - High Temperature Total Organic Carbon (TOC) Analyzer - Technical Datasheet

    TI448C/07/en/10.0971098868Technical InformationTOCII CA72TOCAnalyzer for online-determination of TOC in aqueous media using thermic catalytic combustionApplication• Industrial wastewater monitoring• Control of process wastewater• Monitoring of industrial surface water• Municipal wastewater monitoring• Recording of the carbon load to control the nutrient dosageYour benefits• Optimized for ...

  • Isokinetic 2013 Catalog 1-1-13 NP

    www.apexinst.com919-557-7300 or 800-882-3214Fax: 919-557-7110Website: www.apexinst.comContact: info@apexinst.comApex Instruments, Inc.204 Technology Park LaneFuquay-Varina, N.C. 27526, U.S.A.XC-522XC-5000XC-40IsokInetIc catalogISOKINETIC SOURCE SAMPLING EQUIPMENTFLOW, PRESSURE & TEMPERATUREMERCURY ANd GAS SAMPLING SYSTEMS & EQUIPMENTGAS ANALYSIS EQUIPMENTAPPENdIXINdEX ACCESSORIESMeter ...

  • Aridus Desolvating Sample Introduction System Operator’s Manual

    Aridus Desolvating Sample Introduction System Operator’s Manual Product Warranty Statement SD Acquisition, Inc., DBA CETAC Technologies (“CETAC”), warrants any CETAC unit manufactured or supplied by CETAC for a period beginning on the date of shipment and ending on the sooner to occur of: (a) the date that is twelve (12) months from the date of installation, or (b) the date that is ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you