exposure standard Downloads

  • GEDDS Product Brochure

    Ralph Servaticontact by phone:843.815.2780contact by e-mail:rservati@swtechnologies.comGEDDS: the solution you need when every critical second countsHow comprehensive and e?cient is your system for collecting data and measuring worker's hazardous exposure within the workplace?GEDDS: Exposure level reporting with 14 Years of proven nuclear power plant experienceContact Us Today to Learn more ...

  • Sulfur Dioxide RAM Technical Data Sheet

    Technical Data Sheet: TDS 19 DIFRAM600: RAPID AIR MONITOR – Sulfur dioxide, SO2 Description: A plastic (H.D.P.E.) circular diffusive sampler containing a sorbent for measuring gaseous sulfur dioxide in ambient air. This sampler is designed to provide a considerably higher uptake rate than the passive axial diffusion tube, which allows a higher flexibility of ambient air pollution measuring ...

  • SO2 Rapid Air Monitor Tech Sheet

    TDS19 Ver1 February 2014 Technical Data Sheet: TDS 19 DIFRAM600: RAPID AIR MONITOR – Sulphur dioxide, SO2 Description: A plastic (H.D.P.E.) circular diffusive sampler containing a sorbent for measuring gaseous sulphur dioxide in ambient air. This sampler is designed to provide a considerably higher uptake rate than the passive axial diffusion tube, which allows a higher flexibility of ...

  • Acid gases Technical Data Sheet

    Technical Data Sheet: TDS 3A DIF 900 RTU - ACID GASES This tube is designed for passively monitoring airborne acid gases such as Hydrogen fluoride, Hydrogen chloride, Nitric acid, Hydrogen bromide, Phosphoric acid and Sulfuric acid (HF, HCl, HNO3, HBr, HPO4 and H2SO4). Description: Acrylic tube fitted with green and white thermoplastic rubber caps. The colored cap contains the absorbent. A ...

  • HVManager Data Sheet Brochure

    HVManager™ SoftwareVibration Exposure Assessment and Risk Managementwith the Larson Davis HVM100Larson Davis Toll-Free in USA 888-258-3222 716-926-8243 www.larsondavis.comHighlightsHVManager™ displays and organizes hand/arm and whole body vibration measurementdata that is acquired using the Larson Davis HVM100 Human Vibration Meter. The data isutilized by employers to limit exposure of their ...

  • Anaesthetic Gases Technical Data Sheet

    Technical Data Sheet: TDS 10 DIFMLS5A - NITROUS OXIDE (N2O) and DIFCHR-106 – OTHER ANESTHETIC GASES Workplace monitoring for nitrous oxide and other anesthetic gases has been carried out in hospitals, dentists and other local health authorities for many years. Personal exposure testing has now become an issue amongst staff administering this gas on a regular basis. Diffusive sampling methods for ...

  • VOC RAM Technical Data Sheet

    Technical Data Sheet: TDS 17 DIFRAM-VOC: RAPID AIR MONITOR - VOCs Description: A plastic (H.D.P.E.) circular diffusive sampler containing a sorbent for measuring gaseous volatile organic compounds in ambient air. This sampler is designed to provide a considerably higher uptake rate than the passive axial diffusion tube, and allows a higher flexibility of air pollution monitoring in outdoor and ...

  • Model FM-9-ABNI - Portable PET, Iodine, or Tc-99M DTPA Air Monitor for Gas & Particulates - Brochure

    FEATURES:AIRBORNE CONCENTRATION •INTEGRATED EXPOSURE•HIGH SENSITIVE•REAL TIME ALARM •LINE OPERATED •PORTABLE•STANDARD FM-7/9 MODULES •CAN DRAW AIR FROM HOOD, DUCT, ETC. •QUICK CHANGE FILTER CARTRIDGE •REGULATED AIR FLOW •COMPUTER INTERFACE – USB OR ETHERNET•DATA LOGGER - BUILT-INAPPLICATION:The FM-9- ABNI Air Monitors assure safety against airborne radioactivity contamination by means of constant ...

  • N2O Technical Data Sheet

    Technical Data Sheet: TDS 10 DIFMLS5A - NITROUS OXIDE (N2O) and DIFTXTA – OTHER ANAESTHETIC GASES Nitrous Oxide is widely used as an anaesthetic. The current WEL (workplace exposure limit) for 8 hour time weighted average reference period is 100 parts per million. Workplace monitoring for nitrous oxide has been carried out in hospitals, dentists and ...

  • Premium

    Ethylene Oxide Application Note

    Analyzer The Series 8900 Ethylene Oxide Ana-lyzer combines the selectivity of gas chromatography with the sensitiv-ity of a Photoionization Detector (PID) providing interference free response to Ethylene Oxide (EtO) at levels below 0.05 ppm. This analyti-cal method is referenced in OSHA's "Occupational Exposure to Ethylene Oxide: Final Standard" 29 CFR Part 1910.The system documents exposure ...

  • Nitric Oxide Technical Data Sheet

    Technical Data Sheet: TDS 2 DIF 150 RTU - NITRIC OXIDE (NO) This tube is designed for passively monitoring gaseous airborne nitric oxide Description: The NO/NO2 diffusion tube system consists of a two-tube pack. 1. A conventional nitrogen dioxide tube containing the absorbent in a closed grey cap. 2. A nitrogen oxide tube ...

  • HVM100 Datasheet (For Industrial Hygiene applications) Brochure

    Industrial Hygiene Vibration MonitorComplete Convenient System for Exposure Limit Compliance TestingHighlightsExposure to high levels of vibration has been shown to cause permanent injury ifleft unchecked and untreated. Determining potential for injury from exposure tovibration should be considered part of a comprehensive ergonomic evaluation andrisk assessment program.Model HVM100 from Larson ...

  • Ammonia Rapid Air Monitor Tech Sheet

    TDS18 Ver1 April 2013 Technical Data Sheet: TDS 18 DIFRAM400: RAPID AIR MONITOR – Ammonia, NH3 Description: A plastic (H.D.P.E.) circular diffusive sampler containing a sorbent for measuring gaseous Ammonia in ambient air. This sampler is designed to provide a considerably higher uptake rate than the passive axial diffusion tube, which allows a higher flexibility of ambient air pollution ...

  • Ammonia RAM Technical Data Sheet

    Technical Data Sheet: TDS 18 DIFRAM400: RAPID AIR MONITOR – Ammonia, NH3 Description: A plastic (H.D.P.E.) circular diffusive sampler containing a sorbent for measuring gaseous Ammonia in ambient air. This sampler is designed to provide a considerably higher uptake rate than the passive axial diffusion tube, which allows a higher flexibility of ambient air pollution measuring in outdoor and ...

  • Nitrogen Dioxide Technical Data Sheet

    Technical Data Sheet: TDS 1 DIF 100 RTU - NITROGEN DIOXIDE (NO2) This tube is designed for passively monitoring gaseous airborne Nitrogen dioxide. Description: Acrylic tube fitted with colored* and white thermoplastic rubber caps. The colored cap contains the absorbent. The concentrations of Nitrite ions and hence NO2 chemically adsorbed are quantitatively determined by UV/ Visible ...

  • Ammonia Rapid Air Monitor Technical Data Sheet

    Technical Data Sheet: TDS 18 DIFRAM400: RAPID AIR MONITOR – Ammonia, NH3 Description: A plastic (H.D.P.E.) circular diffusive sampler containing a sorbent for measuring gaseous Ammonia in ambient air. This sampler is designed to provide a considerably higher uptake rate than the passive axial diffusion tube, which allows a higher flexibility of ambient air pollution measuring in outdoor and ...

  • Inorganic Iodides - Potassium Iodide USP Brochure

    Deepwater Chemicals, Inc. PIS101.24.1.04 Revised 08/04/2006 PRODUCT INFORMATION SHEET POTASSIUM IODIDE USP FORMULA: KI DESCRIPTION: White crystals or granular powder; slightly hygroscopic in moist air. Tends to cake during storage. On long exposure to air becomes yellow due to liberation of iodine. Light and moisture accelerates decomposition. CAS NO.: 7681-11-0 AVAILABLE ...

  • SuperScrim - Model WC Product Specifications

    SuperScrim™ WC Product Specifications Properties Test Method Minimum Average Values 9 mil 12 mil 16 mil 20 mil 24 mil 30 mil Weight D5261 5.4 oz/yd2 5.7 oz/yd2 7.2 oz/yd2 9.6 oz/yd2 11.5 oz/yd2 13.4 oz/yd2 Thickness 9 mil 12 mil 16 mil 20 mil 24 mil 30 mil Grab Tensile (lbs.) D751 MD 200 CD 135 MD 210 CD 176 MD 230 CD 210 MD 330 CD 286 MD 352 CD 300 MD 352 CD 300 Mullen Burst D6241 300 psi 350 ...

  • VOC Technical Data Sheet

    Technical Data Sheet: TDS 8 VOLATILE ORGANIC COMPOUNDS This tube is designed for passive (time weighted average concentrations) and active monitoring of volatile and semi-volatile organic compounds in the range C2 – C28. The tube can be used passively for time weighted average concentrations or pumped (active) for workplace monitoring and comparison to health and safety workplace ...

  • VOC technical data sheet

    Technical Data Sheet: TDS 8 VOLATILE ORGANIC COMPOUNDS This tube is designed for passive (time weighted average concentrations) and active monitoring of volatile and semi-volatile organic compounds in the range C2 – C28. The tube can be used passively for time weighted average concentrations or pumped (active) for workplace monitoring and comparison to health and safety workplace ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you