fid total hydrocarbon analyzer manufacturer Downloads

  • Model HC5IM FID Total Hydrocarbon and Total VOC Analyzer Brochure

    THC/Total VOCFID Total Hydrocarbon And total VOC Analyzer Model HC51MLow level monitoringof Total VOCs fromfew ppb to 1000 ppmTwo versions available :• THC : Total hydrocarbon• THC / CH4 /nMHC : Total hydrocarbons, methane and non-methaneApplications :• Ambient air monitoring• Monitoring around industrial sources emitting VOCs• CO2 gas purity process control• Continuous emissions monitoring ...


    By Envitech Bohemia s.r.o.

  • Model 3000HM Heated FID - Total Hydrocarbon Analyzer- Brochure

    The analyser uses the well established principle of Flame Ionisation to detect volatile organic compounds in a gas stream. It incorporates all the knowledge and experience of four generations of product development. New features include a 3U high case, a clean air generator for the FID burner and zero calibration gas, and an improved heated sample conditioning module with built in sample pump. A ...

  • How To Select A Total Hydrocarbon Analyzer For Use In An Industrial Application - Application Notes (PDF 31 KB)

    Control Instruments® Corporation Technical Note How to Select a Total Hydrocarbon Analyzer for use in an Industrial ApplicationFIDs are the best sensor choice Several different sensor technologies may be used to detect hydrocarbons, including: catalytic; photo-ionization; infra-red; gas chromatography; and flame ionization. Of these possibilities, flame ionization (FID) is considered the best ...

  • Model 650 FID - Flame Ionization Detector Brochure

    The Model 650 FID is the Only Total Hydrocarbon Analyzer Specifically Designedfor Industrial Monitoring T from Control Instruments is the first continuous total hydrocarbon analyzer that solves he remarkable Model 650 all the sampling, measuring and reporting problems found in industrial applications. Designed and manufactured specifically for industrial use, the Model ...

  • TerraLab - TRL-TOC/IC/TN - Total Carbon and Nitrogen Analyzer (TOC) - Brochure

    TOC and TN ANALYZERSTRL-TOC Model TC/IC/TOC/TN Analyzers are designed for analysis of: > Heterogeneous samples like sludge, wood, soil, solid waste, biomass and foodstuff> Landfill eluates> Large sample size up to 12 mL (equivalent to 9 gr soil)> High carbon and nitrogen content up to 500 mgC and 30 mgN > Liquid samples with high dissolved and/or suspended solids content> Industrial waste water> ...

  • Model 8000M - Paramagnetic O2 Analyzer - Manual

    The analyser uses a well-established dumb -bell paramagnetic sensor that is sensitive and linear, and will remain serviceable for many years. The sensor is heated to prevent condensation and to minimise drift. A new dimension in operation simplicity has been added by the use of a microprocessor controlled LCD dot matrix display and interactive function keys. Automatic fault free startup and a ...

  • Cost Effective Gas & Vapor Monitoring In Pharmaceutical Manufacturing Facilities - Application Notes (PDF 140 KB)

    Control Instruments®CorporationApplication NoteCost Effective Gas & Vapor Monitoring in Pharmaceutical Manufacturing FacilitiesPharmaceutical facilities use a variety of hazardous gases and solvents in their production processes. Whenever these substances are transported, processed or stored, the potential risks are high for hazardous conditions. These substances must be continuously monitored to ...

  • Premium

    Acetaldehyde, Benzene, Toluene, Ethylbenzene & Xylenes in CO2 Application Note

    The BevAlert Model 8900 provides direct measurement of Acetaldehyde, Benzene, Toluene, Ethylbenzene, and Xylenes (ABTEX) in Carbon Dioxide. The instrument is utilized by Specialty Gas Manufacturers and the Food and Beverage Industry to monitor trace volatile organic compounds in CO 2 used in carbonated ...


    By AMETEK MOCON - Baseline

  • Premium

    Gas Chromatography System GC Brochure

    System GC CatalogNatural Gas, Petrochemical and Other Standard Appl icat ions Shimadzu began building Gas Chromatography products in 1955 and remains committed to building the best GC products in the world. Throughout our long history, the customer’s needs have always been central to all our design, manufacturing, and testing processes.As part of this continuing commitment, we developed the ...

  • Premium

    Ecosorb Odor Eliminator Manual

    This manual is provided as a technical guide for the design engineer and the Ecosorb distributor who specifies odor control ...


    By OMI Industries (OMI)

  • Premium

    Derivatization Reagents: For Selective Response and Detection in Complex Matrices

    Derivatization is a commonly used technique to augment chromatography analysis. It requires efficient and effective reagents that can modify the behavior of complex compounds and allow their detection in chromatographic analysis. Since the release of the last Derivatization guide in 2009, several innovative derivatization reagents have been introduced for various detection methods, and many other ...

  • Premium

    EGAS 2M Engine Exhaust Gas Analysis System Brochure

    EGAS 2MEGAS 2MMultigas analysis cabinet (control unit)Mobile sample handling systemGRAPHITE 52MMIR 2MTOPAZE 32M Main applications• Engine manufacturers and testing companies in the automotive, heavy duty, aviation, marine, rail transport sectors, etc.• Certification Bodies,• Universities and Research Centres,• General engine and/or vehicle performance test,• Development of clean engines,• ...

  • Premium

    Maxum Edition II Process Gas Chromatograph Brochure

    Process Gas ChromatographsMAXUM edition II4/3Siemens PA 01 · 20124¦ Overview The MAXUM edition II is a universal process gas chromatograph for flexible process applications with a wide variety of analytical possibilities. The MAXUM edition II combines various functional modules with a flexible oven concept and can therefore also optimally solve complex applications.The MAXUM edition II is used in ...

  • NJ DEP SOP tables showing accuracy, method detection limit studies and other performance data

    © 2011 Sitelab Corporation Document No. Sitelab_SOP_Rev6_6-9-11 Page 1 of 18 STANDARD OPERATING PROCEDURES SUPPORTING TABLES Pages 8 to 18 for SOIL, SEDIMENT AND WATER REAL-TIME MEASUREMENT METHOD FOR PETROLEUM HYDROCARBONS BY ULTRAVIOLET FLUORESCENCE NJ DEP Certification No. MA013, Sitelab Corporation Sitelab SOP Revision No. Rev 6.0 Submitted to: New Jersey Department of ...


    By Sitelab Corporation

  • Complete SRI Catalog- Brochure

    PRODUCT CATALOGSRI I n s t r u m e n t sU . S . M A N U F A C T U R E R O F C U S T O M G A S C H R O M AT O G R A P H S Y S T E M S20111TermsMinimum Order US $75.00Currency US dollars, Visa, MasterCard, American Express, Wire Transfer, US bank check.Payment Terms 40% deposit, balance net 30 days.Restocking Charge 25% plus 1% per day after 30 days from invoice date.Shipment FOB ...


    By SRI Instruments Europe GmbH

  • Supelco Ionic Liquid GC Columns Applications

    This presentation shows a variety of application which can be performed using Supelco ionic liquid GC columns.Applications1Supelco Ionic Liquid GC ColumnsChromatograms – Environmental ApplicationsApplications2Supelco Ionic Liquid GC ColumnsPolychlorinated biphenyls (PCBs) were widely used as insulating fluids for transformers and capacitors from the 1930’s into the 1980’s. Their use was stopped ...


    By MilliporeSigma

  • Parker Balston - TOC Gas Generator - Brochure

    11 800 343 4048 www.labgasgenerators.comaerospaceclimate controlelectromechanicalfiltrationfluid & gas handlinghydraulicspneumaticsprocess controlsealing & shieldingAnalytical Gas SystemsProducts for TOC AnalysisBulletin AGS-TOCFINAL TOC.indd 1 10/17/2012 1:40:08 PM21 800 343 4048 www.labgasgenerators.comParker Hannifin CorporationThe Global Leader in Motion and Control TechnologiesWe ...


    By Parker Hannifin Corp

  • Petroleum/Chemicals Application Guide

    Bulletin 858D595 North Harrison RoadBellefonte, PA 16823-0048 USATelephone 800-247-6628 ? 814-359-3441Fax 800-447-3044 ? 814-359-3044email: supelco@sial.comsigma-aldrich.com/supelcosigma-aldrich.com/supelcoColumn: Petrocol DH 50.2, 50m x 0.20mm ID, 0.5µm filmCat. No.: 24133-UOven: 35°C (30 min) to 200°C at 2°C/minCarrier: helium, 20cm/sec (set at 35°C)Det.: FID, 225°CInj.: 225°C0 8 16 24 4032 48 ...


    By MilliporeSigma

  • Improved Resolution: SLB-IL60 Ionic Liquid GC Columns

    Products will be available soon. Visit sigma-aldrich.com/il-gc for updates.Supelco SLB-IL60 Ionic Liquid GC ColumnsImproved ResolutionThe variety of analyte-phase interactions possible with the SLB™-IL60 column can be leveraged to provide improved separations. This is espe-cially true for complex mixtures comprised of compounds with varying functionality. Polyethylene glycol (PEG) columns rate at ...


    By MilliporeSigma

  • Environmental Monitoring Products Catalogue

    .Environmental Monitoring Pricelist Environmental Monitoring Products Updated 01/07/20010 Mint Bridge Road Kendal Cumbria Tel: 01539 727878 Email:sales@environmonitoring.co.uk www.environmonitoring.co.uk Index section 1. Gas Sample Probes 2. M&C Gas sampling probes 3. Heated lines and temperature conrollers 4. Gas conditioner – Millennium, M&C 5. Isokinetic samplers & ...


    By Environmental Monitoring

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you