gas burner Downloads
-
ecom - Model UNO - Pressure Measurement Analyser Brochure
For Adjustments of Gas Burners/Gas Heatings. Four changeable units: hPa/mbar, mmH2O, psi, mmHg. Ranges: ± 200 hPa, ± 2038 mmH2O, ± 2.9 psi. and ± 150 mmHg. Accuracy: 1%. Power supply: 2 one-way batteries AA 1.5 V (Mignon). Dimensions (H x W x D): approx. 106 x 64 x 28 mm. Weight: approx. 150 gr (with batteries). Scope of delivery: ecom-UNO, batteries, protective ...
By ecom GmbH
-
ecom - Model DP - Pressure Measurement Profi Set Brochure
For pressure measurements at gas burners. For tightness check of gas fittings (± 100 to 150 mbar). Check of gas connection pressure. Measurement of gas adjustment pressure. Adjustement of gas pressure controller. Adjustment of air pressure ...
By ecom GmbH
-
Vertex™ - Model GDHE-75-100 - Power Direct Vent Gallon Gas Water Heater Brochure
The GDHE-75 Vertex™ Power Direct Vent gas water heater offers unprecedented levels of performance to meet your hot water needs.Featuring a 75-gallon (nominal) tank and a 100,000 BTU gas burner, the GDHE-75 Power Direct Vent delivers a thermal efficiency of 96%, a Uniform Energy Factor of 0.86, and a recovery rate of 129 gallons per hour. It carries a 6-year limited warranty, and meets ...
By A.O. Smith
-
Vertex™ - Model GDHE-75-100 - Power Direct Vent Gallon Gas Water Heater Brochure
The GDHE-75 Vertex™ Power Direct Vent gas water heater offers unprecedented levels of performance to meet your hot water needs.Featuring a 75-gallon (nominal) tank and a 100,000 BTU gas burner, the GDHE-75 Power Direct Vent delivers a thermal efficiency of 96%, a Uniform Energy Factor of 0.86, and a recovery rate of 129 gallons per hour. It carries a 6-year limited warranty, and meets ...
By A.O. Smith
-
Vertex™ - Model GDHE-50 - Power Direct Vent Gallon Gas Water Heater Brochure
The GDHE-50 Vertex™ Power Direct Vent gas water heater is designed specifically to generate a constant flow of 4 gallons per minute, resulting in continuous hot water for your home.Featuring a 50-gallon (nominal) tank and a 100,000 BTU gas burner, the GDHE-50 Power Direct Vent delivers a thermal efficiency of 96%, a Uniform Energy Factor of 0.88, and a recovery rate of 129 gallons per ...
By A.O. Smith
-
Vertex™ - Model GPHE-50 - Power Direct Vent Gallon Gas Water Heater Brochure
The GPHE-50 Vertex Power Vent gas water heater is designed specifically to generate a constant flow of 3 gallons per minute, resulting in continuous hot water for your home.Featuring a 50-gallon (nominal) tank and a 76,000 BTU gas burner, the GPHE-50 Power Vent delivers a thermal efficiency of 94%, a Uniform Energy Factor of 0.88, and a recovery rate of 95 gallons per hour. It carries a 6-year ...
By A.O. Smith
-
Polaris® - Model GTP-175 - High Efficiency GTP Brochure
The ProLine XE Polaris GTP 175 High Efficiency power direct vent gas water heater is the high performance answer for today’s hot water needs. It can provide endless hot water* and can be used for a combination of domestic hot water and space heating.Featuring a 50-gallon (nominal) tank and a 175,000 BTU natural gas burner, the Polaris GTP-175 power direct vent delivers a Thermal ...
By A.O. Smith
-
Polaris® - Model GTP-150 - High Efficiency GTP Brochure
The ProLine XE Polaris® GTP 150 High Efficiency power direct vent gas water heater is the high performance answer for today’s hot water needs. It can provide endless hot water* and can be used for a combination of domestic hot water and space heating. Featuring a 50-gallon (nominal) tank and a 150,000 BTU natural gas burner, the Polaris GTP-150 power direct vent delivers a Thermal ...
By A.O. Smith
-
SpillFix Flammability Report
. temperature 1000C) from a gas burner was applied for 2 minutes. On pic 3. it can be seen thatthe 200 mm ...
-
Model VMH - Safety Shut Off Valves Brochure
Safety shut off valves, slow opening and fast closing with hydraulic or pneumatic actuator.The VMH type valve is a safety shut off valve for gaseous media operated by hydraulic actuator. It is suitable for gas blocking and releasing controls, as required in the main pipe of gas power burners, atmospheric gas boilers, industrial kilns and gas consuming appliances. When the actuator is energized, ...
-
ecom - Model DP - Engine Pressure-Meter Brochure
For pressure measurements at gas engines. Gas pressure control. Differential pressure measurement at air intercoolers. Measurement of flue gas overpressure. Differential pressure measurement at blow-by-filters. Measurement of crankcase pressure. Suitable for pressure measurements at gas heatings / burners. Thermal printer as accessory. Min./Max. function (storage of lowest or highest value). ...
By ecom GmbH
-
Model VRA VLA VTA - Solenoid Valves for Combustion Air Regulation Brochure
The VRA/VLA/VTA types are normally closed solenoid valves for cold combustion air regulation.When the coil is not energized the spring works on the disc, keeping the adjusted minimum passage of air. When powering the coil the valve opens, moving the disc to the maximum open position. When power is switched off the valve moves to the minimum position.This type of device is suitable for high/low ...
-
Dakota - Model II - Fuel Fired Hot Water Pressure Washers Brochure
Sioux's conventional fuel-fired pressure washers are available with electric motors and Liquid Propane, Natural Gas, or Oil fired burners. Dakota II units are also available as self-contained units with an integrated pressure washer/ steam cleaner, water tank and gasoline or diesel engine generator on a heavy duty skid or over the road trailer; these units are excellent for cleaning at remote ...
-
The Design and Installation of the Gas Collection System Brochure
The designer of gas collection plants has the task to fulfill optimally the important criteria: Stability of gas quality, efficiency of collection, economic viability of the plant. The stabilisation of the gas quality helps to solve the problem between the uneven gas production of the landfill on the one side and the steady supply of gas to the utilisation plant, on the other. Only a carefully ...
-
Systronik - Portable Gas Detector - Brochure
The portable gas detector GSP 4 is used to sniff out gas leaks of flammable gases in gas pipes as well as connection pieces and fittings, gas meters, gas burners and gas ...
-
Model LM - Laboratory Muffle Furnace Brochure
APPLICATION Laboratory muffle furnaces for all applications up to 1200 °C. Standard controller Jumo: PID controller with one free programmable heating ramp. Option: Controller SE 40 Li with 25 programs each 25 steps. Temperature increase to Tmax 1340 °C for LM 312, LM 412 and LM 512. (LM 112 up to 1200 °C only). Tilting device for LM 112. Exhaust device, gas flushing, post combustion ...
-
GA series - Direct Propane Gas Heaters Brochure
All GA models with burner relay, ionization flame protection, thermostat connector and hose breakage protection. Clean combustion, easy to maintain. High capacity for low price. Wheels GA 60/85 E available as an accessory. Wheels GA 110 E are standard. Full humidity and dust proof control panel. (Except GA 25 E). Removable exterior cover for service. Gas valves with built-in filter. Twin gas ...
-
Model VMH VMP - Safety Shut off Valves Brochure
Safety shut off valves, slow opening and fast closing with hydraulic or pneumatic actuator.The VMH type valve is a safety shut off valve for gaseous media operated by hydraulic actuator. It is suitable for gas blocking and releasing controls, as required in the main pipe of gas power burners, atmospheric gas boilers, industrial kilns and gas consuming appliances.When the actuator is energized, ...
-
Model S-Series - Hot Water Boilers Brochure
The Sellers immersion fired S-Series hot water boiler is a horizontal, single pass, firetube boiler designed to burn natural gas. The unique burner assembly delivers pre-mixed air and gas through multiple nozzles. The air-gas mixture is ignited as it exits each flame retaining nozzle at high velocity. The resulting flames are long and small in diameter. The flame from each of these nozzles is ...
-
Model M-Series - Hot Water Boiler Brochure
The Sellers immersion fired M-Series hot water boiler is a horizontal, single pass, firetube boiler designed to burn natural gas. The unique burner assembly delivers pre-mixed air and gas through multiple nozzles. The air-gas mixture is ignited as it exits each flame retaining nozzle at high velocity The resulting flames are long and small in diameter. The flame from each of these nozzles is ...
Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you