ground conductivity meter Downloads

  • EM100 & EM102 Installation Instructions

    InstructionsEM 100/102Low FlowElectromagneticFlow MetersInstallationMountingThe EM 100 and EM102 model flow meters may besupported by the piping if the piping is rigid and thereis no vibration. If the piping is subject to vibration it isnot recommended to us the piping as the sole methodof supporting the meter, particularly on the smallersizes. In this case, the flow meter housing may beanchored ...

  • Model 1153 - Digital Conductivity Meter - Manual

    DIGITAL CONDUCTIVITY METER The information contained in the accompanying document is proprietary and confidential, and may not be copied in any manner whatsoever without prior written consent of Emcee Electronics, Inc. The document and the material therein may not be used for any purpose other than that intended by Emcee Electronics, Inc. COPYRIGHT 2005 EMCEE ELECTRONICS, INC. ...

  • GM CMD Dublo

    GM CM-DUBLO ELECTROMAGNETIC CONDUCTIVITY METER FOR DEEP SURVEY Graded depth range (7.5 - 60 m) Manual or continuous measuring modes High temperature stability and noise resistance Smart and rugged design Rechargeable Li-Ion cells (one charging for 1-2 working days) or AA cells Easy control system with graphical screen and large memory Data download via USB port or flash disk Bluetooth ...

  • Model 1152 - Digital Conductivity Meter- Manual

    DIGITAL CONDUCTIVITY METER The information contained in the accompanying document is proprietary and confidential, and may not be copied in any manner whatsoever without prior written consent of Emcee Electronics, Inc. The document and the material therein may not be used for any purpose other than that intended by Emcee Electronics, Inc. COPYRIGHT 2005 EMCEE ELECTRONICS, INC. REVISION DATE: ...

  • Cadillac - Model EMAG - Magnetic Flow Meter Datasheet

    GENERAL INFORMATION Rev 0613 EMAG Series Cadillac® Magnetic Flow Meter CENTRAL STATION STEAM CO.® 15615 SW 74TH AVE., BLDG #150 TIGARD, OR 97224 PHONE: 888-556-3913 FAX: 503-624-6131 @ WWW.CADILLACMETER.COM Cadillac Rev 0613 THE NEW INDUSTRY STANDARD Historically, liquid flows have been measured by mechanical flow meters. However, as with any mechanical system, the meters are subject to wear ...

  • VZOR - MARK-602 - Conductivity Analyzer - Manual

    MAPK-602 CONDUCTIVITY/ SALINITY METER Operation Manual Nizhny Novgorod 2010 ??74 2VZOR Ltd. will be grateful for any proposals and criticisms helping improve the product. If you have any trouble using the instrument please contact us in writing or by phone. Postal address: 603106, Russia, Nizhny Novgorod, POB 253 Telephone: + 7 (831) 229-65-67, ...

    By VZOR

  • Cadillac Meter - Model CMAG - Pumped and Gravity Condensate Meter Datasheet

    Cadillac® Magnetic Flow Meter Central Station Steam Co.® GENERAL INFORMATION 15615 SW 74th Ave., Ste #150 Phone: 888-556-3913 Tigard, OR 97224 Fax: 503-624-6131 www.cadillacmeter.com Rev 1009 CMAG Series Rev 1009 THE NEW INDUSTRY STANDARD Historically, liquid flows have been measured by mechanical flow meters. However, as with any mechanical ...

  • F-1300 Series Inline Turbine Flow Meters Catalog Sheet

    1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699www.onicon.com • sales@onicon.com0227-1 09-09• INLINE FLOW METER •MODEL F-1300 TURBINEFREQUENCY OUTPUTDESCRIPTION ONICON inline turbine fl ow meters are suitable for measuring electrically conductive water-based liquids. The F-1300 model provides a high-resolution frequency output for connection to an ONICON ...

  • EM101 Installation Instructions

    InstructionsEM 101Low FlowElectromagneticFlow MetersInstallationMountingThe EM 101 model has a flow meter unit and aseparate control unit containing a LCD display. Thecontrol unit should be mounted to a secure surfacewith screws or bolts. To gain access to the mountingholes, remove the front cover. The mounting holes aredirectly under the front cover screws. The flow meterunit is supplied with a ...

  • Model 122M - Mini Oil/Water Interface Meters Brochure

    Model 122M - Laser Marked PVDF Coaxial Cable Data SheetMini Interface Meter High Quality Groundwater and Surface Water Monitoring InstrumentationMini Interface MeterModel 122M - Laser Marked PVDF Coaxial Cable Solinst Mini Oil/Water Interface Meters give clear and accurate measurements of product level and thickness in wells and tanks. Determination of both light (floating) non-aqueous phase ...

  • Efcon - Electro Magnetic Flowmeters Datasheet

    EFCON® Compact Electro Magnetic Flowmeter (EMF)Efcon® EMF meters have minimum fouling PTFE lining, empty pipe detection, display with actual & total flow, pulse & analog output. Because of the high accuracy EMF meters are commonly used for effluent discharge purposes of water & sewage.BE AWARE For EMF meters the ‘diameter selection’ is most important Select correct EMF meter ‘diameter’ with ...

  • F-3500 Insertion Electromagnetic Flow Meter Manual

    11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax (727) 442-5699www.onicon.com • sales@onicon.comF-3500 ELECTROMAGNETIC FLOW METERInstallation and Operation Guide05-140665-7 / 1832611451 Belcher Road South, Largo, FL 33773 • USA • +1 Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.comF-3500 Insertion Electromagnetic Flow Meter Manual 05/14 - 0665-7 Page 2SAFETY ...

  • 3919/4119/4120 D344 Conductivity Sensor Brochure

    D344 - May 2011Conductivity Sensor 3919/4119/4120Conductivity is a key parameter for in-situ determination of several fundamental physical properties of seawater. For seawater, the ability to conduct electrical current is mostly dependent on temperature and the amount of inorganic dissolved solids. This means that, together with temperature and depth information, a good estimate of the salinity ...

  • WBL300

    WBL SeriesBlowdown and Feed Boiler Conductivity ControllersRevised 4/19/06Part 1. General 1.1 ScopeA. This section describes the requirements for a blowdown and feed conductivity boiler controller with an automatically temperature compensated electrode. B. Under this item, the contractor shall furnish and install the conductivity control equipment and accessories as indicated on the ...

  • WCT310

    WCT310 SeriesBleed, Feed and Dual Biocide Cooling Tower Conductivity ControllersRevised 4-19-06Part 1. General 1.1 ScopeA. This section describes the requirements for a bleed, feed and dual biocide cooling tower conductivity controller with an automatically temperature compensated electrode. B. Under this item, the contractor shall furnish and install the conductivity control ...

  • F-3100 Series Inline Electromagnetic Flow Meter Manual

    11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax (727) 442-5699 www.onicon.com • sales@onicon.comF-3100 SERIESInline Electromagnetic Flow Meter Installation & Basic Operation Guide06-140670-7 / 1695811451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.comF-3100 Flow Meter Manual 06/14 - 0670-7 Page 211451 Belcher ...

  • ModMAG - Model M1000 - Electromagnetic Flow Meter User Manual

    M-Series® M1000Electromagnetic Flow MeterMAG-UM-00379-EN-03 (January 2015) User ManualM-Series® M1000, Electromagnetic Flow MeterPage ii January 2015MAG-UM-00379-EN-03CONTENTSSafety Precautions and Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • WCT300

    WCT300 SeriesBleed and Feed Cooling Tower Conductivity ControllersRevised 4/19/06Part 1. General 1.1 ScopeA. This section describes the requirements for a bleed and feed cooling tower conductivity controller with an automatically temperature compensated electrode. B. Under this item, the contractor shall furnish and install the conductivity control equipment and accessories as ...

  • WDT300

    WDT300 SeriesBleed and Feed Cooling Tower Conductivity ControllersFor Two TowersRevised 4/19/06Part 1. General 1.1 ScopeA. This section describes the requirements for a bleed and feed cooling tower conductivity controller with automatically temperature compensated electrodes that controls two cooling towers. B. Under this item, the contractor shall furnish and install the ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you