oil sheen monitor Downloads

  • TOC Consumables Catalog

    Hydro-Electric Power PlantsLeakwise* Oil Detection in Collection Sumps and Turbine PitsIn many hydroelectric power plants, water first flows into collection sumps/turbine pits prior to discharging into the river. Sumps/turbine pits catch leaking oil from turbine bearings and can be inundated with oil should a major equipment failure occur. For immediate notification, and to ensure no oil gets ...

  • Leakwise - ID-227 - Oil Sheen Monitoring System For Marine Applications Brochure

    GE Power & WaterWater & Process TechnologiesApplicationsThe Leakwise* ID-227 Oil Sheen Monitoring System is afloating sensor capable of monitoring hydrocarbons orother organic solvents on water. The ID-227 is designedfor installation at offshore oil tanker buoyterminals, jetties, and piers to detect floating oil sheensresulting from spills or leaks occurring during theloading/offloading ...

  • Specifying The Correct Leakwise Sensor Specification

    GE Power & WaterWater & Process TechnologiesThe basic Leakwise* Oil-on-Water Monitoring andDetection System includes a sensor (ID-22x) and an analogcontroller (PS-220). The analog controller includes two drycontact relays (4 Amp) that are usually used to turn off apump, close a valve, etc. It also includes a third fail-saferelay (3 Amp dry contact) to indicate a system failure. Theanalog ...

  • Neptune® AW Hydraulic Fluid For Marine Environments

    American Chemical Technologies, Inc.NEPTUNE® AW SERIES HYDRAULIC FLUIDSNo Sheen, High Performance, Water Soluble Hydraulic FluidsNeptune® AW Series FluidsNeptune® AW Series hydraulic fluids are polyalkylene glycol (PAG) based and comply with U.S. EPA VGP.Neptune® AW Series hydraulic fluids are the only chemistry fully compliant with the 2013 Vessel General Permit (VGP), U.S. EPA Clean Water Act ...

  • Leakwise - ID-227WL/PTP - Oil Sheen Monitoring System Brochure

    GE Power & WaterWater & Process TechnologiesApplicationsThe Leakwise* ID-227WL/PTP Oil Sheen MonitoringSystem is a floating wireless sensor that detects thepresence and monitors the buildup of hydrocarbons onwater. The ID-227WL/PTP is designed for installationoffshore. Applications include detecting and monitoringfloating hydrocarbons near the intake of desalinationplants, jetty and monobuoy oil ...

  • OilTechw2 Oil on Water Sensor Datasheet

    Application NoteCharlestown St Austell Cornwall UK PL25 3NN T:+44(0)1726 879800 F:+(0)1726 879800 E:info@partech.co.uk www.partech.co.ukTitle Goes HereAPPLICATIONSAirport Run-offPower GenerationWater Treatment Intake ProtectionMetal Processing Plant EffluentInland WaterwaysBENEFITSEarly Warning of Pollution IncidentProtection for Membrane PlantsAutomatic Intake ShutdownReduction of ...

  • BilgeRemed - Pretreatment of Oily Bilge Water on boats & Ships Brochure

    Sarva Bio Remed, LLC 310 B Emig Road Emigsville, PA 17318 Phone: 877-717-2782 (US only) BilgeRemed Disclaimer: SpillRemed (Marine)® is on the US EPA’s NCP Product Schedule. This listing does not mean that EPA approves, recommends, licenses, certifies or authorizes the use of SpillRemed (Marine)® on an oil discharge. This listing means only that data have been submitted to the US EPA as ...

  • Leakwise - ID-221 - Oil Sheen Sensor Brochure

    GE Power & WaterWater & Process TechnologiesApplications The Leakwise* ID-221 sensor detects the presence ofand monitors the buildup of thin layers of hydrocarbonson water. Many petroleum and power companies use itfor early detection, warning, and control of oil leaks andspills in wet sumps, tanks, and groundwater monitoringwells with a minimum water level of 30 cm (12.0 in). Otherapplications ...

  • Leakwise - ID-225 - Oil Thickness Sensor Brochure

    GE Power & WaterWater & Process TechnologiesLeakwise ID-225 Applications The Leakwise* ID-225 sensor measures the thicknessand monitors the buildup of hydrocarbons on water.Many petroleum and power companies use it for earlydetection, warning, and control of oil leaks and spills inthe following applications:Remediation Control• Monitoring oil thickness changes over time in ground-water wells to ...

  • Leakwise - ID-223 - Oil Sheen Sensor Brochure

    GE Power & WaterWater & Process TechnologiesApplications The Leakwise* ID-223 sensor detects the presence ofand monitors the buildup of thin layers of hydrocarbonsin wet and dry environments. Many petroleum andpower companies have installed the ID-223 in wet ordry sumps for early detection, warning, and control ofoil leaks and spills from: • Above-ground oil storage tanks• Transformer sumps in ...

  • Partech - Model OilTechw² FLT - Oil on Water Sensor - Manual

    INSTRUCTION MANUALOilTechw² Sensor** This page is intentionally left blank **OilTechw² Instruction ManualTable of Contents1 Foreword........................................................................................................................................................ 52 ...

  • INT Series - Oil/Water Interface Meter - Brochure

    HIGH QUALITY DESIGN Using state-of-the-art electronics, the INT interface meter delivers reliable, rock solid performance in thefield. This allows more readings and more accuratemeasurements compared to other similar instruments.Infra-red refraction is used to detect liquids and conductivity is used to detect the water. For heavy viscous oils, detect water sensitivity quickly by increasingthe ...

  • GWS Environmental Contractors Inc. Steam Project Description

    GWS Environmental Contractors, Inc. ------------------------ Environmental Remediation Specialists ------------------------ Tank Removals, Mold Remediation, Water Damage, Structural Drying 105 Fresh Ponds Road www.gwscontractors.com Phone: (732) 297-4847 Jamesburg, NJ 08831 Fax: (732) 297-4389 NJDEP License # US330445 PROJECT DESCRIPTION FOR SOIL VAPOR ...

  • Model 122M - Mini Oil/Water Interface Meters Brochure

    Model 122M - Laser Marked PVDF Coaxial Cable Data SheetMini Interface Meter High Quality Groundwater and Surface Water Monitoring InstrumentationMini Interface MeterModel 122M - Laser Marked PVDF Coaxial Cable Solinst Mini Oil/Water Interface Meters give clear and accurate measurements of product level and thickness in wells and tanks. Determination of both light (floating) non-aqueous phase ...

  • CIAS Catalog of Products

    A Global Leader ofHydrocarbon Management Solutions2014 Catalog of ProductsSecondary Containment SolutionsC.I.AgentSolutions®11760 Commonwealth Dr. • Louisville, KY 40299 • 866.242.4368 • 502.267.0101 • FAX 502.267.0181 • www.ciagent.com • www.ciagent-stormwater.com • 1536C.I.Agent Solutions, located in Louisville, Kentucky, is ready to handle hydrocarbon management challenges that come our way; ...

  • Model API - Standard Oil Water Separator Brochure

    Pan America Environmental, Inc. 950 N. Rand Rd., Ste 120 Wauconda, IL 60084 847.487.9166 www.panamenv.com panam@panamenv.com ©1991-2013 Pan America Environmental, Inc. API API Design Oil Water Separators The API Series oil water separators are designed per the American Petroleum Institute (API) separator design ...

  • Solinst - Model 122 - Oil/Water Interface Meters - Datasheet

    Interface MeterModel 122 Solinst Oil/Water Interface Meters give clear and accuratemeasurements of product level and thickness in wells and tanks. Determination of both light (floating) non-aqueous phase liquids (LNAPL) and dense (sinking) non-aqueous phase liquids(DNAPL) is quick and easy. The factory-sealed probes arepressure proof and tapes are available in a range of lengthsfrom 65 - 1000 ...

  • Model 122 Interface Meter

    Interface MeterModel 122 Solinst Oil/Water Interface Meters give clear and accuratemeasurements of product level and thickness in wells and tanks. Determination of both light (floating) non-aqueous phase liquids (LNAPL) and dense (sinking) non-aqueous phase liquids(DNAPL) is quick and easy. The factory-sealed probes arepressure proof and tapes are available in a range of lengthsfrom 65 - 1000 ...

  • U.S. ENVIRONMENTAL PROTECTION AGENCY TIER I QUALIFIED FACILITY SPCC PLAN TEMPLATE Instructions to Complete this Template This template is i

    U.S. ENVIRONMENTAL PROTECTION AGENCY TIER I QUALIFIED FACILITY SPCC PLAN TEMPLATE Instructions to Complete this Template This template is intended to help the owner or operator of a Tier I qualified facility develop a self-certified Spill Prevention, Control, and Countermeasure (SPCC) Plan. To use this template, your facility must meet all of the applicability criteria of a Tier I ...

  • Trans Vac 300DH: Operations Manual (PDF 157 KB)

    TRANS-VAC 300DH OPERATING INSTRUCTION MANUAL By SLICKBARPRODUCTS CORPORATION WARNING When skimming petroleum products, flammable vapors may be present within the receiving tank, at the vacuum pump discharge, and inside all piping. The unit must not be operated in the presence of flammable vapors, as uncontrolled engine over-speed can occur. ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you