reductive dechlorination Downloads

  • Premium

    ABC+ - Anaerobic BioChem+ - Datasheet

    ABC+ (Anaerobic BioChem+) is used to promote both anaerobic biodegradation and reductive dechlorination of halogenated solvents in groundwater. ABC+, composed of ABC® (Anaerobic BioChem) and Zero Valent Iron (ZVI), is a mixture of lactates, fatty acids, and a phosphate ...


    By Carus Corporation

  • Hydrogen Release Compound (HRC) Brochure

    FiguRE 1: HyDROGEn RELEASE COMPOUnD, (HRC) SLOW-RELEASE Of LACTIC ACIDH and OH from H20 hydrate HRC and facilitate the release of Lactic Acid Lactic Acid Molecule HRCHRC - Glycerol Polylactate (GPL)LA LALA LALA LALA LALA LALA LAH HC C CH H HFiguRE 2: SIMPLIfIED HRC STRUCTURELactic Acid Pyruvic Acid Acetic AcidO OOHCCH3 CHH O OOCCH3 COOHCH3 CHCO2 CCICI C CICI CIHCCIH C CICI CI HCCIH C HCI ...


    By REGENESIS

  • KB-1® Sheet

    KB-1® is a naturally occurring, non-pathogenic microbial culture that contains Dehalococcoides (Dhc), the only group of microorganisms documented to promote the complete dechlorination of chlorinated ethenes to non-toxic ethene. Although Dhc are found in the environment, research indicates these microorganisms are not ubiquitous and not all Dhc are capable of complete dechlorination of ...


    By SIREM

  • Premium

    ADVANCEES - Company Profile - Brochure

    Reverse Osmosis Systems: Advancees can provide desalination or high purity water systems capable of producing up to 30 million gallons per day. Feed water sources include seawater, brackish water, tap water or pre-treated wastewater. Membrane Softening: Membrane softening replaces lime softening for drinking water systems. It reduces hardness and TDS to any preferred level, removes ...

  • Chlorinated Solvent Remediation Technologies

    Our solutions guide for Enhanced Reductive Dechlorination ...


    By Tersus Environmental, LLC

  • TSI DC Bioaugmentation CultureTM

    1035 Philadelphia Pike Suite E Wilmington Delaware 19809 302-798-9553 Fax 302-798-9554 www.terrasystems.net TSI DC Bioaugmentation CultureTM TSI DC Bioaugmentation CultureTM is an enriched natural bacteria culture that contains Dehalococcoides species for bioaugmentation. This culture dechlorinates tetrachloroethene (PCE) and trichloroethene (TCE) to the non-toxic product ethene. The ...


    By Terra Systems, Inc. (TSI)

  • HiSOC Presentation (PDF 725 KB)

    TechnologiesinVenturesHiSOC® byAnaerobic Chlorinated Hydrocarbon RemediationHiSOC® Hydrogen inFusion SystemTechnologiesinVenturesHiSOC® byWhat is HiSOC®?• Based on iSOC® Gas inFusion Technology• Hydrogen gas is used to enhance anaerobic reducing conditions• System powered by compressed gas in cylinder• Mass transfer device delivers dissolved hydrogen to treatment zone • No moving parts; Installs ...

  • EOS - Model VOS - Thixotropic (Shear-Thinning) Emulsified Vegetable Oil (EVO) - Datasheet

    EOS VOS is a thixotropic (shear-thinning) emulsified oil formulation of biodegradable oil, water, nutrients, and alkaline buffers designed to mitigate groundwater impacts caused by residual contaminants in the unsaturated (vadose) zone. EOS VOS patented technology uses green chemistry to help microbes breakdown contaminants in soil before they reach groundwater. Once injected, EOS VOS creates a ...


    By EOS Remediation, LLC

  • REGENESIS Remediation Technologies Catalog 2014

    GroundwaterBioaugmentationSOILCHLORINATED SOLVENTSPetroleum HydrocarbonsENHANCED DESORPTIONENHANCED AEROBIC BIODEGRADATIONENHANCED ANAEROBIC BIODEGRADATIONIn-Situ Chemical OxidationWWW.REGENESIS .COMAdvanced Technologies for Contaminated Site RemediationOur Products SupportAdvanced Technologies for Contaminated Site RemediationAdvanced Technologies for Contaminated Site RemediationCONTENTS1 ...


    By Regenesis

  • 3-D Microemulsion Brochure

    Case study #2 A site in Florida was characterized with Pce contamination approaching 225 ug/L A total of 1,080 pounds of 3Dme was applied via 16 direct-push injection points to reduce Pce concen- trations. monitoring results in well mw-103 indicated a Pce reduction of approximately 67% within 75 days of the 3Dme application. Pce concentrations continued to decline by 96% one year ...


    By Regenesis

  • BOS 100 and BOS 200 - BOS Trap & Treat Brochure

    Graham Bells Vej 23A 8200 Aarhus N Denmark Tlf: +45 87 31 00 60 www.ejlskov.comCase Study - BOS100® Remediation in a former Industrial Facility in StockholmIntroFrom July to December 2011, the BOS 100® technology was implemented to treat groundwater and soil impacted by PCE, TCE and other chlorinated hydrocarbons in a former industrial facility in the northern part of Stockholm. The site has been ...


    By EJLSKOV A/S

  • gPRO LP and EVO Chlorinated Hydrocarbon Remediation (PDF 681 KB)

    gPRO® by inVentures inVenturesgPRO® byTechnologiesChlorinated Hydrocarbon RemediationgPRO® LP Hydrogen inFusion Systemwww.gproinfo.com TechnologiesinVenturesgPRO® byWhat is gPRO® LP• A superior gas delivery system based on inVentures’ Gas inFusion Technology • Mass transfer device delivers high amounts of dissolved hydrogen to treatment zone• gPRO LP system is submerged directly into the body of ...

  • ToxProtect - Model 64 - Automated Monitoring System Brochure

    The ToxProtect64 is an automated monitoring system for the protection of a drinking water supply against accidental or malicious contamination due to harmful substances. The characteristics of such threats are a relatively high concentration of dangerous substances that occurs suddenly. This challenging task requires a number of important criteria to be met. Such a system MUST be sensitive to a ...


    By bbe Moldaenke GmbH

  • BIO FRAC for enhanced Bioremediation

    Frac Rite Environmental Ltd.*BIO-FRACING FOR ENHANCED IN SITU BIOREMEDIATION OF CHLORINATED SOLVENTS IN LOW PERMEABILITY SEDIMENTSFrac Rite Environmental Ltd.Frac Rite Environmental Ltd.*Outline Challenges to in situ bioremediation Environmental soil fracturing – an enabling technologyFracture-enhanced in situ bioremediation of CAHs case studyConclusionsFrac Rite Environmental Ltd.Frac Rite ...

  • KDF Process Media POU Brochure

    Pressure Drop as a Functionof Flow RatePercent Free Chlorine Reduction as aFunction of Flow RateTemperature Effecton Free Chlorine ReductionFor every 25°F raise in temperature there is a 4%raise in the rate of free chlorine reductionHelping Carbon DoWhat Carbon Does BestBy reducing inorganic contaminantsbefore they get to the carbon bed, KDF 55Process Medium protects GAC frombacterial fouling and ...


    By KDF Fluid Treatment, Inc.

  • MF-1000 Series Industrial Steel Tank Media Filter Brochure (PDF 273 KB)

    Why a pressure filter? Pure Aqua pressure filters clarify water by removing sediment, turbidity, iron, unpleasant tastes and odors, suspended particles, and unwanted color, all of which are commonly found in surface water. They can be used in a variety of service conditions including, but not limited to: industrial, municipal, and institutional applications. Filter ...


    By Pure Aqua, Inc.

  • Provect-IR™ Antimethanogenic ISCR Reagent - Technical Data Sheet

    1 Technical Data Sheet www.ProvectusEnvironmental.com • tel: (815) 650-2230 • fax: (815) 650-2232 • email: info@provectusenvironmental.com Provect-IR, Provect-OX, Provect-GS and Provect-CH4 are registered trademarks of Provectus Environmental Products, Inc. v4 – June 16, 2014 • Copyright ©2014 Provectus Environmental Products, Inc. Provect-IR™ Antimethanogenic ISCR Reagent TECHNOLOGY ...

  • Industrial Wastewater Treatment Optimization Brochure

    ALTECH is a leader in applying proven technical knowledge and effective problem-solving for a broad range of industrial clients. Services Optimization of Water and Wastewater Systems Turnkey Treatment Design and Installation Pilot Plant and Full-scale Testing Remote Monitoring and Control Permitting and Approvals Procedure Assessment and Process Streamlining ...


    By Altech Technology Systems

  • US EPA Office ox`f Solid Waste And Emergency Response, 2000 (PDF 2.186 MB)

    United StatesEnvironmental ProtectionAgencySolid Waste and Emergency Response (5102G)EPA 542-R-00-008July 2000 (revised)www.epa.govclu-in.org EPA Engineered Approaches to In Situ Bioremediation of Chlorinated Solvents: Fundamentals and Field ApplicationsEPA 542-R-00-008July 2000 (revised)ENGINEERED APPROACHES TO IN SITU BIOREMEDIATION OF CHLORINATED SOLVENTS:FUNDAMENTALS AND FIELD ...


    By RNAS Remediation Products

  • Premium

    Getting the Most Out of Your Reverse Osmose - Brochure

    Membrane Fouling Considerations The feed water, depending on its source, may contain various concentrations of suspended solids and dissolved matter. Suspended solids may consist of inorganic particles, colloids and biological debris such as microorganisms and algae. Dissolved matter may consists of highly soluble salts, such as chlorides, and sparingly soluble salts, such as carbonates, ...


    By Lenntech Water Treatment

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you