stack gas probe Downloads

  • Premium

    Stack and Fume Hood Sampling - Brochure

    Stack & Fume Hood Sampling HI-Q28 7386 Trade Street / San Diego, CA 92121 / Phone 858-549-2820 / Fax 858-549-9657 / Order Online @ www.HI-Q.netHI-Q is ready tohelp with your stacksampling requirements:State and Federal nuclear regulatoryagencies require a stack discharge samplingprogram as part of the licensing process. Radionuclidesdischarged to the air in the form of particulate and ...

  • Premium

    Cerex - Model FT5000P - Insitu Probe CEMs, Multi-Gas FTIR Stack Analzyer - Brochure

      The CEREX FT5000P... ...one device for all your in-situ monitoring   FT5000P FTIR MulO-Gas Probe Analyzer CONTACT: 1816 Briarwood Industrial Court, Suite D Atlanta, GA. 30329 678-570-6662 www.cerexms.com sales@cerexms.com Cerex’s FTIR ConOnuous MulOgas Analyzer, engineered specifically for low cost, high performance monitor-ing of in-situ process applicaOons. ...

  • Premium

    Stack and Fume Hood Sampling-II - Brochure

    HI-Q Stack & Fume Hood Sampling7386 Trade Street / San Diego, CA 92121 / Phone 858-549-2820 / Fax 858-549-9657 / Order Online @ www.HI-Q.net 29Ordering InformationHI-Q Environmental Products Company’s product line includes complete sampling systems, consisting of either type of probe, the transport line, sampling pump andflow controller. We recommend, design, and supply complete systems. HI-Q ...

  • Premium

    MultiTrak - Model 670S - Multi-Point Gas Mass Flow Meters for Large Ducts and Stacks - Datasheet

    High-PerformanceMulti-PointMass Flow Meter SystemFor Large Ducts & Stacks? Direct mass flow monitoring eliminates the need for separate temperature and pressure inputs? Accuracy +/- 1 % of reading plus 0.5% of full scale? Patented Dry-Sense™ technology eliminates sensor drift? State-of-the-art calibration facility ensures a highly accurate calibration that matches the application? High ...

  • Gas Sample Probe- Brochure

    © Ankersmid Products, http://www.ankersmidsampling.com, Ankersmid Sampling products manufacturing Neerlandweg 22, 2610 Wilrijk, Belgium Tel.: +32(0)3/820.80.00 Fax: +32(0)3/230.98.58 Stationary Gas Sample Probe Series ASP Version ASP 300, ASP 400, ASP 500 Heated Application The ASP gas sample probes are designed for continuous gas sampling in difficult processes with gases of high ...

  • 275E - Extractive Gas Sample Probe Brochure

    MAN.275E.REVC.03112015Instruction ManualModel 275EExtractive Gas Sample Probe 5200 Convair Drive Carson City, NV 89706 • Phone: 775-883-2500 • Fax: 775-883-6388 • www.universalanalyzers.comPage 2 of 34 Page 3 of 34MAN.275E.REVC.03112015ContentsReceiving and Storage 3Definition of Symbols 4Specifications 5Description and Principle of Operation 6Installation 7Electrical Connections ...

  • Mercury Stack Gas Monitor SM-3 - Brochure

    MERCURY INSTRUMENTSANALYTICAL TECHNOLOGIESSM-3 Mercury Stack Gas Monitor Continuous Emission Monitor (CEM) for Mercury? Detects elemental, ionic and bound mercury? Thermocatalytic principle - no use of reagents? Maintenance-free solid state catalyst? True continuous measurement (no measuring cycle)? 3 ranges selectable? Corrosion protected rugged construction ? Approved by German AuthoritiesThe ...

  • Premium

    Codel - Model GCEM4000 - Multi-Channel In-Situ Flue Gas Analyser - Datasheet

    Environmental Monitoring Solutions www.codel.co.ukCODELDoc i/d : 100019 Issue : A Rev : 1 Date : 02/8/2010 © 2010 CODEL International Ltd. We reserve the right to modify designs without prior noticeMulti-species infrared absorption analyser - Accurate, reliable and low maintenance technologyIn-situ stainless steel probe measurement - No sample lines requiredGas temperature and ...

  • Premium

    LANCOM4 - Portable Flue Gas Monitoring - Brochure

    Portable Flue Gas MonitoringLANCOM 4COLow COHigh COLow/H2comp NO NOx NO2 CO2 H2 S SO2 CX HYwww.lancom4.comMonitoring of up 17 measurement parameters one instrument to meet all requirementsUp to 9 gas measurements in a single instrument User selectableHigh quality colour display Visualise your data with new widescreen displayMultiple Language support Navigate the menu in English, French, ...


    By AMETEK Land

  • Premium

    QuadraTherm - Model 640i/780i - Air/Gas Thermal Insertion Mass Flow Meters - Datasheet

    NEVER before possible. QuadraTherm 640i/780i THERMAL MASS FLOW METER TM From Sierra’s beginning over forty years ago, Founder Dr. John G. Olin was driven by the vision of supplying industrial customers with the world’s most accurate thermal mass flow meter. And, he knew it was a “sensor” game. The development of an industrialized metal-sheathed sensor in the early 80s was Sierra’s ...

  • M9096 Mini Stack Train- Isokinetic Sampler

    Westech Instrument Services Ltd, Unit 10 Rectory Farm Business Park, Upper Stondon, Bedfordshire, SG16 6LJ. UK Tel: +44 (0) 1462 816966. Fax: +44 (0) 1462 817050. M9096 Mini Stack Train: Isokinetic Sampler In-Stack Manual Method Particulate Sampler for ISO9096, EN13284-1, US EPA Method 17. Lightweight construction with case suitable for easy transportation. Modular Sample Probe & Pitot ...

  • Premium

    IMR 5000 1-12 Cell Continuous Flue-Gas Analyzer Brochure

    Environmental Equipment, Inc. IMR 5000 Page 1 of 10 IMR 5000 Continuous Flue Gas Monitoring System • The IMR 5000 is state-of-the-art continuous flue-gas monitoring system, and is designed for a wide variety of flue-gas monitoring applications. • The IMR 5000 is a stand-alone analyzer that works automatically. The rugged wall mounted enclosure meets NEMA type 4X (IP65) standards. • The ...

  • 270SF - Heated Sample Probe Brochure

    Universal Analyzers Inc.5200 Convair Drive • Carson City, NV 89706 • Phone: (775)883-2500 • Fax: (775)883-6388 • Toll Free: (800)993-9309sales@universalanalyzers.com • www.UniversalAnalyzers.com270 Series Gas Sample ProbeFor Use in Hazardous (Electrically Classified) Areas FM, CSA & ATEX Certifications©UNIVERSAL • U0003-270FLYR •30 SEPT 11GENERAL DESCRIPTION:The Universal Analyzers Model 270 ...

  • Mercury Air Cooled Probe Flyer

    Mercury Air Cooled ProbeAir-Cooled Probes in High TemperatureStack Gas EnvironmentsPart Number DescriptionHGPA-4-HSo 4 Foot ProbeHGPA-6-HSo 6 Foot ProbeHGPA-9-HSo 9 Foot ProbeHGPA-12-HSo 12 Foot ProbeAir-Cooled Mercury ProbesLosing Test Runs & Data Because of Excessive Temperatures? Apex Air-Cooled Sorbent Trap Probes are the Solution.www.apexinst.com800-882-3214 / 919-557-7300Air Cooled ...


    By Apex Instruments, Inc.

  • Model 110 H - Stack Monitoring Analyzer Brochure

    HOT FID VOC/THC RACK MOUNTED MONITOR Mod. 110H For continuous source monitoring, showing a very fast response time. According to EN 12619 and EN 13526 European directives. PCF ELETTRONICA S.R.L. • Fast response analyser • Separation of methane fraction • In built Zero air supply • In built wide screen data logger FID DETECTOR The detector is an heated carbon atom counter. Sample is ...


    By PCF Elettronica S.r.l.

  • Premium

    IMR 1400CO 2x CO-Sensors - Flue-Gas Analyzer For The Professional Brochure

    ?Environmental Equipment, Inc. 3634 Central Ave. · St. Petersburg, Florida 33711 · Phone 727-328-2818 · 800-RING-IMR · FAX 727/328-2826 · E-mail: info@imrusa.com www.imrusa.com THE PRIDE OF THE COMPANY - MADE IN USA - © Copyright 2006 IMR Environmental Equipment, Inc. COMBUSTION GAS ANALYZER IMR 1400 CO IMR 1400 CO The combustion gas analyzer IMR 1400 CO is easy to use, compact and ...

  • Premium

    IMR 1050X 1-3-Cell Hand-Held Flue-Gas Analyzer Brochure

    Environmental Equipment, Inc.     www.imrusa.com 3634 Central Ave. St. Petersburg, Fl 33711 * Phone: 727-328-2818 * 1-800-RING-IMR * Fax: 727-328-2826    Email: info@imrusa.com  Page 1 of 3 IMR 1050X  IMR 1050X ...

  • PACE - Model 1410 Heated Stack Filter Box Brochure

    Heated Filter Box Features ? 316 Stainless Steel Box ? 3” 150lb Flange Connection ? Easy Filter Access ? Standard Design Contact PACE for details at (610) 262-3818 Introduction The PACE Heated Stack Filter Box is constructed of 316 Stainless Steel and designed to be mounted in an outdoor environment on an emissions stack. A stainless steel probe extending halfway into the stack is connected ...


    By PACE Environmental

  • AtexP-Fibre - Safe Contamination Probe Brochure

    Featuring:radiation monitoring systemsA Mirion Technologies DivisionPIM 206S Combination MonitorsPIM 206 SParticulate and Iodine Monitor The PIM 206S monitor forms part of the RAMSYS product line. It has been developed to continuously measure the particulate and iodine volumetric activities in stacks, ventilation ducts or working areas. It integrates all the functions and performances of the ABPM ...


    By Mirion Technologies

  • Premium

    Cerex - Model UV3000P - Insitu DeNOx, DeSOx, Multi - Gas Continuous Emissions Monitor - Brochure

    Continuous Insitu Multi-Component Monitoring ...DeSOx, DeNOx, Ammonia Slip CONTACT: Cerex Monitoring Solutions, LLC. 1816 Briarwood Industrial Ct. Ste D Atlanta, GA. 30329 678-570-6662 www.cerexms.com Ammonia Slip / DeNOx DeSOx / Flue Gas Desulfurization General CEMs UV3000P Insitu DeNOx, DeSOx, Multi-Gas Continuous Emissions Monitor ®Windows is a registered trademark of Microsoft ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you