surface sample Downloads
-
Premium
RapidVap - Model 7910001 - N2 Dry Evaporation System - Datasheet
The RapidVap N2 Evaporation Systems offer a more efficient, automatic alternative to Kuderna-Danish and rotary evaporators and may be used with a broad range of aggressive chemicals. In RapidVap N2 Systems, a stream of nitrogen or dry gas is directed downward onto the surface of the sample. Nitrogen blow down reduces the partial pressure directly over the liquid to speed evaporation and help ...
-
Premium
RapidVap - Model 7910000 - N2 Dry Evaporation System - Datasheet
The RapidVap N2 Evaporation Systems offer a more efficient, automatic alternative to Kuderna-Danish and rotary evaporators and may be used with a broad range of aggressive chemicals. In RapidVap N2 Systems, a stream of nitrogen or dry gas is directed downward onto the surface of the sample. Nitrogen blow down reduces the partial pressure directly over the liquid to speed evaporation and help ...
-
Premium
RapidVap Vertex Evaporator - Manual
Congratulations on your purchase of a Labconco RapidVap Vertex Evaporator. Models are available for operation on 115V or 230V. Superior evaporation rates are achieved by the unique blending of several gentle forces on the sample. The vials containing the sample are held at an angle to increase the surface area of the sample thereby increasing the evaporation rate. A precisely controlled amount of ...
-
Premium
Eijkelkamp - Sandbox for pF-Determination - Operating Instructions Manual
This Sandbox (acc. to ISO 11274) (art. no.: 0801) can be used to apply a range of pressures from pF 0 (saturation) to pF 2.0 (-100 hPa). Sand is used to convey the suction from the drainage system to the soil samples. The surface of the sand is flexible, which makes it easier to restore the contact between it, and the samples, after they have been removed for weighing. This quality makes sand a ...
-
Premium
Tekran - Model 2642 - Natural Gas Sampler - Brochure
Tekran and VE Technology have partnered together to improve the quality of Natural Gas sampling and analysis. Proper sample collection requires precision equipment to assure mercury is quantitatively transported between the source pipeline and the sample collection device. The Tekran 2642 Natural Gas Sampler paired with a Tekran 2600-NG provides a complete sampling and analysis solution. Sampling ...
-
Premium
RapidVap - Model 7910013 - N2/48 Dry Evaporation System - Datasheet
RapidVap N2/48 Evaporation Systems use nitrogen blow down, vortex motion and heat to speed evaporation of up to 48 small samples or eight 450 milliliter samples at once. A stream of nitrogen or dry gas is directed downward onto the surface of the sample. Nitrogen blow down reduces the partial pressure directly over the liquid to speed evaporation and help remove the solvent as it evaporates. ...
-
Premium
RapidVap - Model 7910012 - N2/48 Dry Evaporation System - Datasheet
RapidVap N2/48 Evaporation Systems use nitrogen blow down, vortex motion and heat to speed evaporation of up to 48 small samples or eight 450 milliliter samples at once. A stream of nitrogen or dry gas is directed downward onto the surface of the sample. Nitrogen blow down reduces the partial pressure directly over the liquid to speed evaporation and help remove the solvent as it evaporates. ...
-
Krinkle Spills w/ Surface Sampling Report
Object MovedThis document may be found ...
-
Scanning Electrochemical Microscopy System (SECM ) Brochure
The SECM integrates a positioning system, a bipotentiostat, and an ultramicroelectrode tip. The positioning system moves the tip close to the surface of the sample. The bipotentiostat polarizes both the sample and the tip independently and measures both resulting currents. The tip is an ultramicroelectrode with a specific tapered polish and active radius lower than 100 microns. The positioning ...
-
PUC - Model BET - Surface Area Analyser Brochure
The Macsorb surface area analysers determine the specific surface area of samples by the BET method. They are controlled from a desktop computer using the software supplied with the unit. Fully automated handling of samples effectively prevents operator error. The high repeatability of the measurment results confirm the precision of the analyser and allowing users to obtain well-founded data ...
-
Premium
Application - Determination of the total mercury in a filtrate of wash-off samples from contaminated surfaces
Introduction Quantitative determination of the total mercury content in filtrates of wash-off samples from the surfaces of walls, floors, equipment, and other facilities of m anufacturing areas is an effective method for the occupational safety ...
-
Saccharoflex - Model 2020 - Colorimeter Brochure
The SCHMIDT + HAENSCH electronic reflectance-meter for the automatic color grading of crystalline sugar according to the recommendations of ICUMSA, method GS2-11 (1994)and GS2-13 (1994). With this instrument the reflectance factors at 495 nm and 620 nm are measured and the ratio is indicated in terms of color type numbers. The measurement is done by use of Taylor’s law and an integrated ...
-
PHI - Model PHI 710 - Scanning Auger Nanoprobe Brochure
The PHI 710 Scanning Auger Nanoprobe is a unique, high performance Auger Electron Spectroscopy (AES) instrument that provides elemental and chemical state information from sample surfaces and nano-scale features, thin films, and interfaces. Designed as a high performance Auger, the PHI 710 provides the superior Auger imaging performance, spatial resolution, sensitivity, and the spectral energy ...
-
MULTI KAPPA - Magnetic Susceptibility Meter Brochure
Multi Kappa instrument serves for fast field survey allowing both spot measurement and mapping by means of several probes. Together with GF Instruments traditional pocket magnetic susceptibility meters cover wide range of demands for accurate susceptibility measurement on ground surface, outcrops and samples of rock and soil. Original efficient way of temperature stabilizing allows profiling ...
-
Hanon - Model HN200 - Sample Concentrator - Datasheet
Blowing the nitrogen into the surface of the heated samples, so that the dissolvent in the samples can be evaporated and separated quickly, which comes up to the oxygen-free concentration and keeps the higher pureness of samples. The use of sample concentration instead of the commonly used rotary evaporimeter for concentration, can have simultaneous concentration of dozens of samples, which makes ...
-
BioSpot - Condensation Growth Tube Collector Brochure
The BioSpot collector performs much like the human lung, providing high-efficiency, gentle collection into liquid through condensationally enhanced inertial deposition. A laminar-flow condensation growth tube (CGT) encapsulates airborne particles into liquid droplets and gently deposits the droplets onto a liquid surface. The air sample flow is 8 L/min, equal to the average rate at which a person ...
-
P-Class - NanoPhotometer Brochure
to independence of sample surface tension; No issues of column formation with low surface tension ...
By Implen Inc
-
The Investigation of Boron Measurement Utilizing Varian Vista – MPX Simultaneous ICP-OES with Radial Viewing and CETAC Technologies Ultrasonic Nebulizer
The Investigation of Boron Measurement Utilizing Varian Vista – MPX Simultaneous ICP-OES with Radial Viewing and CETAC Technologies Ultrasonic Nebulizer The ICP-OES technique has many advantages over atomic absorption techniques for the determination of boron (B). The detection limits are low while the linear range is quite broad. However, boron will adhere to glass surfaces in the sample ...
-
Scanning Electron Microscope JSM-6510LV Series Brochure
is a program that takes stereo pair SEM images and constructs a three dimensional (3D) image of the ...
By Jeol USA Inc
-
Sani-Check - Model APB - Acid Producing Bacteria Test Kit - Datasheet
Disinfect hands with an alcohol wipe before handling any of the test kit components. Open one Agar Tube and place screw cap side up on a clean, dry surface. Remove sterile Sample Applicator Swab from the envelope (do not touch the swab side). Insert Sample Applicator Swab into the liquid sample for approximately 10 seconds. For solid samples, use the Sample Applicator directly to swab the ...
Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you