  • Leak Noise Loggers

    Datamatic, Ltd.3600 K Avenue Plano, TX 75074800-880-2878 Toll-free972-234-5000 Phone972-234-1134 Faxwww.datamatic.com© 2008 Datamatic, Ltd. All rights reserved. Due to continuous R&D and enhancements, Datamatic reserves the right to change product or system specificationswithout notice..WE READ YOUPermalog+®Leak Noise Logger A Serious IssueLeaks cost utilities and customers dearly. Wasting ...


    By Datamatic LTD

  • Leak Noise Correlator- Brochure

    Water leak detection productsRadiodetection’s range of advanced water leak detection equipment for infrastructure professionalsWater conservation is a critical part in achieving environmental sustainability and preventing water leaks saves money, time and valuable resources. Radiodetection’s next-generation water leak detectors, noise loggers and correlators are designed to help water industry ...


    By SPX Corporation

  • Phocus - Model 3 - Wireless Noise Logger for Leak Detection Brochure

    Primayertechnology for network management and leakage control Wireless noise logger for leak detectionPhocus3 is an advanced leak noise logger designed for detecting and localising water leakage. Wireless communications allows both ‘lift and shift’ or permanent distribution network operation. On site leakage results may be obtained via the Communications Module with detailed analysis carried ...


    By Primayer Ltd

  • Water Leak Detection Products Brochure

    Water leak detection productsRadiodetection’s range of advanced water leak detection equipment for infrastructure professionalsWater conservation is a critical part in achieving environmental sustainability and preventing water leaks saves money, time and valuable resources. Radiodetection’s next-generation water leak detectors, noise loggers and correlators are designed to help water industry ...

  • RD521 - Noise Logging System Manual

    RD521Noise logging systemOperation Manual l Issue 2 l June 200990/RD521-OPMAN-ENG/02ii RD521 Operation Manual RD521 Operation Manual iiiPrefaceBefore you beginThank you for your interest in Radiodetection’s RD521 water monitoring system.Please read this user manual before attempting to use the RD521 system.Radiodetection products, including this manual, are under continuous development. The ...

  • Water Meters FIREFLY

    Datamatic, Ltd.3600 K Avenue Plano, TX 75074800-880-2878 Toll-free972-234-5000 Phone972-234-1134 Faxwww.datamatic.com© 2008 Datamatic, Ltd. All rights reserved. Deployment FlexibilityThe Water FIREFLY (FF) installs in minutes on virtually ANY water meter and ensures the smoothest possible deployment by giving utilities the option of reading via walk-by, mobile or mesh network collection ...


    By Datamatic LTD

  • Drinking Water Sondes Operations Manual

    6-SERIES DRINKING WATER SYSTEMS 600DW-B Sonde 6920DW Sonde 650 MDS Display/Logger 6500 Process Monitor Environmental Monitoring Systems SAFETY NOTES TECHNICAL SUPPORT AND WARRANTY INFORMATION Contact information for technical support and warranty information on YSI’s Environmental Monitoring Systems products can be found in Section 8, Warranty and ...


    By YSI - a Xylem brand

  • Model NexBeta-ABG - Facility Drinking Water Safety Monitor - Brochure

    FACILITY DRINKING WATER SAFETY MONITOR Model Series - NEX-BETA-ABG PROTECT VULNERABLE – HOSPITALS – SCHOOLS – GOVERNMENT FACILITIES TECHNCIAL ASSOCIATES 7051 Eton Ave., Canoga Park, CA 91303 818-883-7043 (Phone) 818-883-6103 (Fax) tagold@nwc.net WWW.TECH-ASSOCIATES.COM A Division of FEATURES: •DETECTS ALPHA, BETA AND GAMMA RADIATION •AVAILABLE IN ...


    By Technical Associates

  • 6-Series Multiparameter Water Quality Sondes User Manual

    6-Series Multiparameter Water Quality Sondes User Manual 6-Series: 6600 V2 6600EDS V2 6920 V2 6820 V2 600 OMS V2 600XL 600XLM 600LS 600R 600QS SAFETY NOTES TECHNICAL SUPPORT AND WARRANTY INFORMATION Contact information for technical support and warranty information on YSI’s Environmental Monitoring Systems products can be found in Section ...


    By YSI - a Xylem brand

  • Well Watch - Model 660 - Water Level Indicator User Manual

    Eno Scientific Well Watch 660DL Page 1 WELL WATCH 660DLSonic Water Level IndicatorUSER MANUALEno Scientific PO Box 1586Hillsborough, NC 27278USAwww.enoscientific.com910-778-2660Copyright NoticeCopyright © 2014 Eno Scientific, Hillsborough, NC 27278, USA.All rights reserved.Part number: 661-901-6611 Eno Scientific Well Watch 660DL Page 2 WELL WATCH 660DLUSER MANUALTable of ContentsPRODUCT ...


    By Eno Scientific

  • Leakage Locator (Tracer Gas)- Brochure

    Water leak detection products Radiodetection’s range of advanced water leak detection equipment for infrastructure professionals Water conservation is a critical part in achieving environmental sustainability and preventing water leaks saves money, time and valuable resources. Radiodetection’s next-generation water leak detectors, noise loggers and correlators are designed to help water ...


    By SPX Corporation

  • Premium

    TAPI - Model T201 - Chemiluminescence NH3 Analyzer - Manual

    MANUAL ADDENDUM MODEL T201 AMMONIA ANALYZER (For use with the T200 Operators Manual, P/N 06858) TELEDYNE ADVANCED POLLUTION INSTRUMENTATION (TELEDYNE-API) 9480 CARROLL PARK DRIVE SAN DIEGO, CA 92121-5201 TOLL-FREE: 800-324-5190 FAX: 858-657-9816 TEL: 858-657-9800 E-MAIL: api-sales@teledyne.com WEB SITE: www.teledyne-api.com Copyright 2011-2013 07271B DCN6646 Teledyne ...


    By Teledyne API

  • Premium

    TAPI - Model 200EH / 200EM - Manual

    INSTRUCTION MANUAL MODEL 200EH/EM NITROGEN OXIDES ANALYZER © TELEDYNE ADVANCED POLLUTION INSTRUMENTATION 9480 CARROLL PARK DRIVE SAN DIEGO, CA 92121-5201 USA Toll-free Phone: 800-324-5190 Phone: 858-657-9800 Fax: 858-657-9816 Email: api-sales@teledyne.com Website: http://www.teledyne-api.com/ 04521 Rev. C DCN 5731 Copyright 2007-2010 Teledyne Advanced Pollution Instrumentation 14 ...


    By Teledyne API

  • Premium

    TAPI - Model 200E - Manual

    TECHNICAL MANUAL MODEL 200E NITROGEN OXIDE ANALYZER © TELEDYNE ADVANCED POLLUTION INSTRUMENTATION DIVISION (TAPI) 9480 CARROLL PARK DRIVE SAN DIEGO, CALIFORNIA 92121-5201 USA Toll-free Phone: 800-324-5190 Phone: 858-657-9800 Fax: 858-657-9816 Email: api-sales@teledyne.com Website: http://www.teledyne-api.com/ 04410 Rev D Copyright 2007-2010 DCN 5731 Teledyne Advanced Pollution ...


    By Teledyne API

  • CCD - Catalytic Combustion Detector Datasheet

    The Catalytic Combustion Detector responds to all hydrocarbons withthe selectivity of an FID and the sensitivity of a TCD. The entire detector’sdiameter is merely one centimeter. Its sensor element consists of a tiny coilof platinum wire embedded in a catalytic ceramic bead. Each CCD detectorhas a pair of sensor elements. The sensors are housed in high-grade, flame-proof nylon, and ...

  • AquaProbe 2 - Insertion-Type Electromagnetic Probe Flowmeter Data Sheet

    Data sheet DS/AQUAP2–EN Rev. J AquaProbe 2Insertion-type electromagnetic probe flowmeterMaximum performance, minimum hassleNow available for use with CheckMaster, Explorer and MagMaster— an innovative, portable validation resourceExcellent accuracy over wide operating flow range in both forward and reverse flow directions— enables accurate measurement of peak daytime flows and minimal night ...

  • Premium

    TAPI - Model T100 - UV Fluorescence SO2 Analyzer - Manual

    Operation Manual Model T100 UV Fluorescence SO2 Analyzer Also supports operation of: when used in conjunction with: Model T100U Analyzer T100U addendum, PN 06840 Model T100H Analyzer T100H addendum, PN 07265 Model T108 Analyzer T108 addendum, PN 07268 Model T108U Analyzer T100U addendum, PN 06840, and T108 addendum, PN 07268 © TELEDYNE ADVANCED POLLUTION INSTRUMENTATION (TAPI) 9480 ...


    By Teledyne API

  • Premium

    TAPI - Model T101 - UV Fluorescence H2S Analyzer - Manual

    OPERATION MANUAL MODEL T101 UV FLUORESCENCE H2S ANALYZER Also supports operation of: Model T102 Analyzer (when used in conjunction with T102 Addendum, PN 07267) © TELEDYNE ADVANCED POLLUTION INSTRUMENTATION 9480 CARROLL PARK DRIVE SAN DIEGO, CA 92121-5201 USA Toll-free Phone: 800-324-5190 Phone: 858-657-9800 Fax: 858-657-9816 Email: api-sales@teledyne.com Website: ...


    By Teledyne API

  • Premium

    API - Model 101E - Manual

    OPERATION MANUAL Model 101E UV Fluorescence H2S Analyzer Also supports operation of: Model M102E Analyzer (when used in conjunction with M102E Addendum, PN 04988) © TELEDYNE ADVANCED POLLUTION INSTRUMENTATION (TAPI) 9480 CARROLL PARK DRIVE SAN DIEGO, CA 92121-5201 USA Toll-free Phone: 800-324-5190 Phone: 858-657-9800 Fax: 858-657-9816 Email: api-sales@teledyne.com Website: ...


    By Teledyne API

  • Premium

    Penetrologger Manual

    1PENETROLOGGERAll it takes for environmental researchP.O. Box 4, 6987 ZG Giesbeek, the NetherlandsT +31 313 88 02 00F +31 313 88 02 99E info@eijkelkamp.comI www.eijkelkamp.comM1.06.15.SA.E© June 2013OPERATiNG iNsTRucTiONsBrand dataHardware version : 6.00Software version : 6.03PenetroViewer version : 6.08Serial number :2ContentsOn these operating instructions ...