Only show results in Texas? Ok

cooling tower legionella control (Cooling Towers) equipment

  • Premium

    ProMinent SlimFLEX - Model 5a - Controller

    The cooling tower regulator SlimFLEX 5 continuously measures and controls conductivity and controls biocide metering, keeps pipework and heat exchangers clean and prevents legionella.

    By ProMinent GmbH based in Heidelberg, GERMANY. from Measuring, Control and Sensor Technology - Controllers Product line

  • Premium

    Kurita - Model NT - Innovative Biofouling Control Technology

    Biofouling is a major problem for the efficient operation of an open cooling water system. Slime produced by bacteria can very quickly form strong stable biofilm on heat exchanger, pipework and tower fill surfaces with really undesired consequences: Fast development - can be within days. Decrease heat transfer - 1µm of biofilm = 5 ...

    By Kurita based in Tokyo, JAPAN. from Innovations Product line

  • Cooling Tower

    Control of scaling, corrosion and the development of bacteria, particularly Legionella, are the objectives Odyssee Environnement has set for your facility : Our company has established its own treatment strategy : BIOTECHNOLOGY, based on the use of a bio-dispersant which destroys the biofilm (harbouring bacteria, Legionella in particular…).

    By Odyssee Environnement based in Requeil, FRANCE. from Solutions Product line

  • DTK - Model LTK0050F - Universal Rapid Legionella Kit

    The Universal Rapid Legionella Test Kit is a breakthrough in technology for the on-site rapid detection of Legionella pneumophila serogroup 1. This versatile kit can be used for testing cooling towers, hot and cold water systems, showers and more.

    By DTK Water (droptestkits) based in Northamptonshire, UNITED KINGDOM. from Test Kits Product line

  • Legionella - Model IL-CT Series - Cooling Tower UV Disinfection System

    The IL-CT Series is used to disinfect cooling tower waters and is effective at legionella control.   UV light is an excellent technology for cooling tower water disinfection. UV works on all microorganisms but there are chlorine resistant microorganisms. Replace expensive primary biocide equipment with relatively low cost UV and ...

    By Glasco Ultraviolet based in Mahwah, NEW JERSEY (USA).

  • Cannon-Water - Model BD200 - Biomass Dispersant

    Super concentrated: 5.0 - 30 ounces treats 1000 gallons of cooling tower water. Penetrates and lifts biomass, slime and dirt from cooling tower and pipe surfaces. Reduces corrosion by cleaning biofilms that can create localized corrosion cells. Helps deprive organisms of food by preventing nutrient rich biomass from forming and accumulating. ...

    By Cannon Water Technology Inc. based in Granite Bay, CALIFORNIA (USA). from Water Treatment Chemicals - Biocides And Dispersants Product line

  • Biosan - Legionella Laboratory Testing

    Biosan Laboratories specializes in independent Legionella testing for cooling towers, evaporative condensers, spas, fountains and other water sources.  In addition to over 40 years of lab experience in environmental microbiological testing, we are also certified by the Center for Disease Control (CDC) Environmental Legionella ...

    By Biosan Laboratories, Inc. based in Warren, MICHIGAN (USA). from Microbiological Laboratory Testing Product line

  • Ozone Water Treatment System

    SkySEP developed a system using ozone to treat water in cooling systems for buildings and industries. This process disinfects the water and removes the biofilm and scaling accumulated in the pipes of the cooling towers while reducing water consumption by 20-40% depending on the system. Ozone used in our systems is a powerful non-polluting and ...

    By SkySEP based in Sherbrooke, QUEBEC (CANADA).

  • LC series

    The LC series model will disinfect clean, clear quality drinking water, cooling tower water for the control of legionella pneumophila bacteria and also reduces algae growth with some hydrogen peroxide. It will disinfect hydrotherapy, swimming and spa pool water in conjunction with an oxidant residual.

    By UVTA based in Glynde, AUSTRALIA.

  • NORKEM - Securox

    A simpler, safer way for ClO2 on demand. Our innovative Securox makes the use of ClO2 simpler, safer and most importantly, cost effective. Securox has many built in features, that can be adapted to your specific application: ie. cooling towers, food industries, oil industries and more. Securox has been adopted in more and more countries as a state ...

    By NORKEM INC. based in Brampton, ONTARIO (CANADA).

  • DCW Neuthox - Model T10 Series - Standard ECA Unit

    The T10 standard ECA unit is designed for legionella control in cooling towers and smaller water supply systems. It is available in five capacities: production of 15, 30, 50, 75 and 100 liter NEUTHOX® per hour in a concentration of 500 PPM FAC (FAC: Free Active Chlorine). The size of generator you require is dependent on the ...

    By Danish Clean Water A/S based in S√łnderborg, DENMARK.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you