Only show results available in Connecticut? Ok

flue gas condensation (Flue Gas Cleaning) equipment

  • Premium

    ZETIAN Hygronom - Model HM-200 - Hygronom

    HM-200 hygronom is an intelligent humidity/ oxygen transmitter, which employs microprocessor as the core, and frequency conversion icon oxygen sensor as measuring unit. The installation method adopts heat tracing pipeline installation. It is a self-developed product, of which, core component is from Switzerland.Under effect of air pump, the flue ...

  • Premium

    Multigas Dilution System

    Ideal for mid-high to high concentrations or for sampling locations in hazardous areas. The flue gas is extracted, filtered & diluted with clean / dry air, by an in-stack dilution probe, before being sent to the analyzer. This technique lowers the flue gas dew point, keeping the sample temperature above it and at ambient temperature, in order ...

  • Premium

    Continuous Emission Monitoring System TDLAS+DOAS

    CEMS has four basic parts: the dust monitoring subsystem, gaseous pollutants monitoring subsystem, flue gas parameter monitoring subsystem, system control and data acquisition and processing subsystem. It can monitor SO2, NOx, O2, dust, temperature, pressure, flow rate and other parameters such as HCl, HF, CO, CO2 for specific occasions. After ...

    By HANGZHOU ZETIAN TECHNOLOGY CO., LTD based in Hangzhou, CHINA.

  • Premium

    Continuous Emission Monitoring System

    CEMS has four basic parts: the dust monitoring subsystem, gaseous pollutants monitoring subsystem, flue gas parameter monitoring subsystem, system control and data acquisition and processing subsystem. It can monitor SO2, NOx, O2, dust, temperature, pressure, flow rate and other parameters such as HCl, HF, CO, CO2 for a particular occasion. After ...

    By HANGZHOU ZETIAN TECHNOLOGY CO., LTD based in Hangzhou, CHINA.

  • Premium

    ZETIAN - Model EM-5-HW - Continuous Emission Monitoring System

    CEMS has four basic parts: the dust monitoring subsystem, gaseous pollutants monitoring subsystem, flue gas parameter monitoring subsystem, system control and data acquisition and processing subsystem. It can monitor SO2, NOx, O2, dust, temperature, pressure, flow rate and other parameters such as HCl, HF, CO, CO2 for specific occasions. ...

  • Flue Gas Condensers

    The flue gas condenser supplied by Van Dijk heating has been a success for more than 35 years now. The Van Dijk heating flue gas condenser was introduced back in 1976, making it one of our oldest products. A flue gas condenser makes it possible to cool down flue gases to a temperature below the dew point and, by doing this, utilise the ...

    By van Dijk heating B.V. based in Bunnik, NETHERLANDS. from Greenhouse Energy Saving Equipment Product line

  • Premium

    PCME - Model STACK 181 WS - Particulate Continuous Emission Monitor

    The PCME STACK 181 WS is suitable for measuring particulate emissions from wet scrubbers and other processes where the flue gas falls below dew point (cold stack conditions) or water droplets are present. The extractive instrument takes a representative continuous sample from the stack, heats this well above dew point to evaporate water droplets ...

    By ENVEA based in Poissy, FRANCE. from Particulate CEMS Product line

  • Flue Gas Condensation

    Flue gas condensation is a proven process for maximizing energy output from damp or hydrogen-rich fuels. By burning of biomass, peat, waste or natural gas, flue gas contains a high proportion of water vapor. Water vapor condenses through cooling of flue gas with the return of district heat. The heat energy released during condensation is thereby ...

    By Envibat AB based in Skellefteå, SWEDEN. from Gas Cleaning Product line

  • Premium

    ZETIAN - Model EM-5-CD - Continuous Emission Monitoring System

    CEMS has four basic parts: the dust monitoring subsystem, gaseous pollutants monitoring subsystem, flue gas parameter monitoring subsystem, system control and data acquisition and processing subsystem. It can monitor SO2, NOx, O2, dust, temperature, pressure, flow rate and other parameters such as HCl, HF, CO, CO2 for specific occasions. ...

  • Flue Gas Condensation System

    By using AGRO Flue Gas Condensation, biomass furnaces can be operated with condensing technology. By the energy-efficient utilisation of latent warmth at a return temperature of lower than 45° C, over 100% efficiency can be achieved. The self-cleaning model of the AGRO Flue Gas Condensation is particularly advantageous.

    By Agro Forst & Energietechnik GmbH based in St. Paul im Lavanttal, AUSTRIA. from Flue Gas Condensation Product line

  • Premium

    PCME - Model QAL 182 WS - Particulate Continuous Emission Monitor

    The PCME QAL 182 WS is suitable for measuring particulate emissions from wet scrubbers and other processes where the flue gas falls below dew point (cold stack conditions) or water droplets are present. The extractive instrument takes a representative continuous sample from the stack, heats this well above dew point to evaporate water droplets and ...

    By ENVEA based in Poissy, FRANCE. from Particulate CEMS Product line

  • Radscan - Flue Gas Condensate System

    Flue gas condensate was traditionally treated with flocculation, precipitation and sand & carbon filter. We did so until 2006 when the last traditional purification plant was installed. Since then we used membrane technology which provides several significant advantages in terms of energy and chemical savings.

    By Radscan Intervex AB based in Västerås, SWEDEN.

  • Radscan - Flue Gas Condensation System

    Flue gas condensation is historically Radscan's strongest business with more than 50 unique projects in the reference list. The basis of the technology is a wet fuel (typically biomass or waste) and a low grade heat recipient (typically district heating). In conventional plants the moisture in the fuel is vaporized prior to combustion of the fuel, ...

    By Radscan Intervex AB based in Västerås, SWEDEN.

  • Synergy - Boiler Flue Gas Condensing Energy Saving Technology

    Generally speaking, efficiency of the fuel and gas boiler can be calculated or verified according to the burning lower heating value. Fuel High Calorific Value = Low Calorific Value + Latent Heat of Vaporization from Flue Gas. High heating value of fuel is used for calculating lower heating value and latent heat of vaporization of flue gas ...

    By Synergy World Limited based in Hong Kong, CHINA. from Energy Saving Product line

  • Radscan - Combining Flue Gas Condensation with Flue Gas Cleaning System

    Combining flue gas condensation with flue gas cleaning seems to be a natural choice. The treatment method is chosen depending on the process and cleaning requirements, but also in consultation with the customer. The cleaning is usually done with scrubbers or fabric filters with activated carbon and lime dosing. Our proprietary Intervex process is ...

    By Radscan Intervex AB based in Västerås, SWEDEN.

  • Premium

    FRP QUENCH

    FRP QUENCH (including Separator casing + Condenser hood ) with these specifications (design temperature: 200 °; length : 12,7 m; Height : 4,8 m ; Width : 4,8 m)GCER had the opportunity to do all the detail engineering, the supply ,manufacture and transport of the “FRP Equipment” for the construction of 1 Line of Flue Gas Treatment ...

    By GCER based in Ksibet, TUNISIA.

  • Dualis - Model EP - GP - Concentric Flue System for Condensing Gas & Oil Boilers

    The Dualis EP-GP provides a concentric flue solution for room-sealed gas or oil fired condensing boiler. . It brings the combustion air in and also evacuates the smoke. It is ideally suited for operating temperature up to 120°C and comes with a 10 year Axa backed guarantee. The Terminal can be either vertical through the roof (Type C3) or ...

    By Poujoulat UK LTD based in Guildford, UNITED KINGDOM. from Concentric Flue System for Domestic Boilers Product line

  • Euro Tech - Model ET3900 - Flue Gas Conditioner for Continuous Emission Monitoring and Stack Sampling

    The heated sample extraction gas conditioner of ET3900 is designed for continuous extraction of gas from a process or exhaust stream; stack testing and process monitoring. The heated probes heat the gas sample and keep it hot to eliminate condensation. ET3900 flue gas pretreatment instrument by heated sampling probe, composition and the rapid ...

    By Euro Tech (Far East) Ltd. based in Wong Chuk Hang, CHINA. from Scientific Equipment Product line

  • Hybrid Percomtherm Direct Contact Water Heater

    The HYBRID PERCOMTHERM is a 'DIRECT-CONTACT', condensing stack economizer which is equipped with an integral, fully modulating burner. Therefore, the HYBRID provides boiler flue gas heat recovery from existing boilers, and provides its own heat source to completely satisfy process hot water demand. Hot water is produced at temperatures as high as ...

    By SOFAME Technologies Inc. based in Montreal, QUEBEC (CANADA).

  • Envitech - Condenser/Absorber

    The Condenser/Absorber sub-cools and scrubs acids from the gas. Reducing the gas volume through condensation of the water vapor significantly lowers energy requirements. Also, heavy metals such as mercury, lead and cadmium are condensed for collection. The Condenser/Absorber condenses out more than eighty percent of the flue gas moisture. The ...

    By Envitech, Inc. based in San Diego, CALIFORNIA (USA).

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you