Flame Detection Downloads

  • Premium

    JCT - Model JPAG - Pure Air Generator - Datasheet

    Applications: Zero air generator for zero check and calibration of gas analysers. For dilution of calibration gas. For dilution of reaction mixture with zero gas at gas phase titration (GPT). For hydrocarbon-free burner air supply of GC combustion detectors like e.g. flame ionisation detectors ...


    By JCT Analysentechnik GmbH

  • Premium

    JPAG Pure Air Generator Datasheet

    Applications: For zero check and calibration of gas analysers. For dilution of calibration gas. For dilution of reaction mixture with zero gas at gas phase titration (GPT). For hydrocarbon-free burner air supply of GC combustion detectors like e.g. flame ionisation detectors ...


    By JCT Analysentechnik GmbH

  • Premium

    H2PD Hydrogen Generator Datasheet

    Applications: For ultra high purity hydrogen production with electrolytic selective palladium membrane technology. Fuel gas for flame ionisation detectors (FID), nitrogen phosphor detectors (NPD) and flame photometric detectors. For carrier gas applications like gas chromatography (GC) and gas chromatography with mass spectrometry coupling ...


    By JCT Analysentechnik GmbH

  • Premium

    Model 602 and 611 - Flame Detector - Datasheet

    In confined public areas where the risk of fire is ever-present, the need for adequate fire detection is becoming increasingly important if unnecessary loss of life is to be avoided. The CODEL Model 602 & 611 are designed to detect the ultra-violet light emitted by an open flame and to provide the earliest time for alarm and so maximise the time to instigate fire-fighting and evacuation ...


    By Codel International Ltd

  • Premium

    ChromaTHC - Total Hydro Carbons Analysis - Brochure

    Monitoring and analysis of Methane and Non-Methane. Total Hydrocarbons (NMTHC) by flame ionisation ...


    By Chromatotec Group

  • Premium

    CHROMA CO CO / CO2 / CH4 /HCHO Analysis - Brochure

    A gas analyser using flame detection with a catalytic methaniser module to analyse CO/CH4 and CO2 for air or gas monitoring. A 19" inch rack mountable chassis, 5U high. It has the ability to be used as a fully integrated system for automatic sample analysis as well as a transportable unit for use on various sites. Our application flexibility allows the chromaCO start up to meet the customer's ...


    By Chromatotec Group

  • Premium

    Polaris - Model FID - Portable Flame Ionization Detection Analyzer Brochure

    POLARIS FID is an on-site portable TOC Analyser for Stack Emissions in compliance with EN12619, EN13526 and EPA METHOD 25A. It is TÜV Rheinald certified. It is a fully portable instrument because it incorporates everything needed for the ...


    By Pollution Srl

  • Premium

    AEREON - Model CEMs - Sentinel Ultraviolet Flame Monitor - Brochure

    The sentinel pilot monitor was designed and developed in order to satisfy several objectives: remote flame detection, reliability, durability, ease of maintenance, and rapid response time. The result is an extremely reliable, durable and inexpensive pilot monitoring device. The sentinel is used to detect the presence of a pilot flame at distances of up to 550 feet. If the monitor detects the ...


    By AEREON

  • Premium

    PORTAFID - Model M3/M3K - Portable Flame Ionisation Detector Operating Instructions Manual

    Congratulations. You have chosen a quality instrument manufactured by Hermann Sewerin GmbH. Our equipment will provide you with the highest standards of performance, safety and efficiency. They correspond with the national and international guide-lines. Please read and understand the following operating instructions before using the equipment; they will help you to use the instrument quickly and ...


    By Hermann Sewerin GmbH

  • Premium

    PORTAFID - Model M3/M3K - Portable Flame Ionisation Detector Brochure

    The PORTAFID M3 / PORTAFID M3K portable flame ionisation detector is the perfect tool for surveying gas pipes. It is reliable and highly accurate, resistant to interference from moisture and is hydrocarbon specific. The has a 0.1 l fuel gas bottle housed under the detector and the carries a larger 0.4 l fuel bottle in an ergonomic back ...


    By Hermann Sewerin GmbH

  • FlameVision - Model FV400 - Flame Detector Brochure

    The FlameVision FV400 Flame Detector uses a Triple IR solar blind technology combined with flame detection algorithms to provide high performance sensing capabilities for hydrocarbon fires. This provides a reliable, cost-effective solution in standard flame detection applications where there is a single hazard in the field of view. This includes the ability to reliably sense flames through high ...


    By Tyco Gas & Flame Detection

  • Model EZ - Flame Detection System Brochure

    A truly advanced and user friendly flame detection system engineered for critical safety functions in the Power Generation, Petrochemical, Metallurgy, and Pulp & Paper industries. Dual channel capabilities for IR, UV, or a combination UV and IR flame scanners provide flexibility to our customers. Each channel on the amplifier can store two user defined program files to distinguish unique ...


    By Safe-Fire Inc.

  • Model W - Flame - Fully Integrated Optical Flame Detection System Brochure

    W-Flame is a fully integrated optical flame detection system that is ideal for monitoring single and multiple burner applications in the petrochemical, metallurgical, power generation, and Pulp & Paper industries. It is engineered to accurately detect burner flames at various stages of boiler startup and operation. This reduces the risk of a potentially dangerous condition where unburned fuel ...


    By Safe-Fire Inc.

  • Measuring Total VOC via FTIR Brochure

    The most common, and current standard, method for measuring Total Volatile Organic Compounds (VOC) is the use of a Flamed Ionisation Detector (FID). This gives a representative value of the total carbon content of a gas stream, as the FID cannot tell which specific organic compounds are ...


    By Protea Limited

  • Model SS2 - Fire Sentry Flame Detector Brochure

    These multi-spectrum flame detectors sense radiant energy in the ultraviolet (UV), visible and WideBand InfraredTM (IR) spectrum. The Fire Sentry SS2-AM and Fire Sentry SS2-AML are the ultra-high speed digital Multi-Spectrum optical models of the Fire Sentry SS2 UV/IR Flame Detectors. These detectors feature ultra-high speed responses to explosive fires and are typically used in munitions ...


    By Honeywell Analytics, Inc.

  • Model SS4 - Fire Sentry Flame Detector Brochure

    Electro-optical digital detectors represent leading edge UV and UV/IR technology. The Fire Sentry SS4-A represents the world’s pre-eminent UV/IR technology for Electro-Optical Flame Detectors with tens of thousands successfully operating in a multitude of installations worldwide. This multi-spectrum detector senses radiant energy in the ultraviolet (UV), visible and Wide Band ...


    By Honeywell Analytics, Inc.

  • SMC - Model 3600-LB - UV/IR Flame Detector - Brochure

    Sierra Monitor’s 3600-LB flame detector monitors hydrocarbon-based fuel and gas fires, hydroxyl and hydrogen fires, as well as metal and inorganic ...


    By Sierra Monitor Corporation

  • UV Flame Detector Brochure

    FIREGUARD’S ultra-violet (UV) flame detector delivers protection you can trust-the protection you need! The detector reacts to the UV radiation found in hydrocarbon fires, delivering accurate and reliable fire monitoring. Its smart sensor technology even detects hard to see hydrogen, ammonia and sulphur fires. As an added advantage, the UVS does not react when exposed to incandescent or ...

  • Model 10C & 12B - Single Sensor Control Card Systems Brochure

    Detcon Model Series 10 and 12 gas detection and alarm systems consist of single sensor control cards that can be integrated into one system design to create multi-function monitoring and control of a wide range of field devices. Field devices include gas detection sensors, flame and fire detection devices and process sensors. Each control card is capable of supervising a single field device, ...

  • Measurement Solution for Measuring Total VOC via FTIR - Application Datasheet

    Current Total VOC Measurements The most common, and current standard, method for measuring Total Volatile Organic Compounds (VOC) is the use of a Flamed Ionisation Detector (FID). This gives a representative value of the total carbon content of a gas stream, as the FID cannot tell which specific organic compounds are ...


    By Protea Limited

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you