  • Production of high-accuracy ethanol calibration gas

    Fast and highly accurate analyzer system was needed for ethanol calibration gas standards. Precisive`s OXS-3100-HC configured for ethanol gas was selected due to its sub-ppm repeatability and high stability.

    By MKS Instruments, Inc. based in Andover, MASSACHUSETTS (USA).

  • Premium

    Continuous emissions monitoring for mining & smelting

    OPSIS non-contact monitoring solutions, based on either DOAS or TDL techniques, are very well suited for applications in the mining and smelting Industries, as the flue gas conditions often involve high temperatures and high dust concentrations.

    By Opsis AB based in Furulund, SWEDEN.

  • Premium

    Continuous emissions monitoring for glass manufacturing

    Process control and emissions monitoring in a glass manufacturing plant is a challenge due to high temperature in the flue gas. The OPSIS DOAS system provides the glass industry with an accurate analyser that will operate with a minimum of maintenance. The OPSIS DOAS system is based on a non-contact method that uses an optical path to measure across the duct.

    By Opsis AB based in Furulund, SWEDEN.

  • Premium

    Continuous emissions monitoring for brick plants

    Process control and emissions monitoring in a brick plant is a challenge due to the high concentrations of HF. The HF is generated in the process and gas phase HF can reach 50 mg/m3 or more. To use an extractive system in this environment will demand a lot of maintanence.

    By Opsis AB based in Furulund, SWEDEN.

  • Premium

    Continuous emissions monitoring for cement industry

    Process control and emissions monitoring in cement plants, can be a challenge due to the dusty and corrosive environment. OPSIS provides an accurate system that will operate with high performance and a minimum of maintenance.

    By Opsis AB based in Furulund, SWEDEN.

  • Premium

    Gas analysis & monitoring system for gas generation

    The gas generators for calibration based on the use of “Method of Permeation Tubes.”. The permeation tubes are sealed capsules containing a small amount of the component that is in contact with a permeable membrane stable. The permeation through the membrane produces a vapor of the compound of the component of small quantity, very stable as a stream in time. This permeate stream by mixing with a dilution gas controlled and precise (for example nitrogen) creates a mixture in track at the desired concentration. The flow of the permeate is measured metrically through severe weight loss of the tube thus ensuring a standard high precision.

    By ETG Risorse e Tecnologia based in Montiglio, ITALY.

  • Premium

    Emissions Monitoring for Sulphuric Acid Production

    Opsis offers complete system packages for on-line measurements in sulphuric acid plants. A system may be used in order to increase plant efficiency as well as monitoring the emissions.

    By Opsis AB based in Furulund, SWEDEN.

  • Ambient Monitor Gas Calibration with Ozone Generators

    Environics® Ambient Monitor Calibrator with Ozone Generators facilitate dynamic calibration of ambient air analyzers. These instruments automatically perform zero, precision, span and multi-point calibrations using NO, NO2, SO2, CO, O3, hydrocarbons and other gases of interest. All ozone generators are factory calibrated using a NIST traceable ozone standard. The Series 6100, Series 6103 and Series 9100 all meet or exceed U.S. Environmental Protection Agency requirements.

    By Environics, Inc. based in Tolland, CONNECTICUT (USA).

  • calibration gas

    calibration gas , British specialty gases company, with a local North Africa presence. We can supply you with high quality gas mixtures for a wide range of applications including Environmental Monitoring, Gas Detection, Mud Logging, Laser Cutting, and Laboratory Analysis. Our gas mixtures are used in the Oil, Gas and Petrochemical industries Our main focus is to give our customers gravimetrically produced, high precision calibration gas mixtures conforming to ISO 6142, along with a range of high purity gases and pressure control equipment, used for instrumental analysis and gas detection applications. AG Gases' senior management have many years experience in the European and International markets and now offer this knowledge to benefit Egyptian and North African customers.

    By AG Gases Ltd based in Stoke-on-Trent, UNITED KINGDOM.

  • Premium

    Emissions Monitoring for Cement Plants

    Opsis provides state-of-the-art monitoring equipment, fully meeting the high standards of monitoring performance and reliability that the cement industry requires. The Opsis in situ systems are designed to withstand environments with high particulate levels and high temperatures.

    By Opsis AB based in Furulund, SWEDEN.

  • Premium

    Raw-gas monitoring for scrubber optimizing

    The consumption of scrubbing material in a scrubber is related to the mass flow of acid gases. Hydrogen chloride (HCl) and sulphur dioxide (SO2) are the major acid gases in an incinerator. By measuring the mass flow of SO2 and HCl in the raw gas going into the scrubber, it is possible to calculate the required quantity of scrubbing material.

    By Opsis AB based in Furulund, SWEDEN.

  • Premium

    Measurement of methane and non-methane hydrocarbons for environmental air quality.

    The Model 8900 Methane/Non-Methane Analyzer provides direct measurement of Methane and Non-Methane Hydrocarbons. This instrument is utilized in ambient air monitoring networks around metropolitan areas, fence-line monitoring at industrial plants and hazardous waste sites, and in the production of high purity industrial gases. Methane is a naturally occurring gas generated from the decomposition of biological materials and industrial activity. Since Methane is not considered a pollutant it is the Non-Methane hydrocarbons that are of primary concern.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of C1-C5 hydrocarbons for oil & gas exploration.

    The PetroAlert Model 8900 combines the selectivity of gas chromatography with the sensitivity, broad dynamic range, and hydrocarbon selectivity of a flame ionization detector (FID) providing fast analysis of C1-C5 hydrocarbons required in Mud Logging for Oil & Gas exploration. The PetroAlert Model 8900 uses a dual column configuration with timed backflush to vent which is used to strip off moisture and C6+ hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed sample volume is carried to the pre-cut column. Backflush of the pre-cut column is timed from sample injection so that only C1-C5 hydrocarbons are eluted from the pre-cut column to the analytical column. C6+ hydrocarbons on the pre-cut column are then vented. C1-C5 hydrocarbons are separated on the analytical column and elute to the flame ionization detector (FID) for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Continuous emissions monitoring for mineral wool production

    Process control and emissions monitoring in a mineral wool plant is a challenge due to the presence of phenol and formaldehyde. To use an extractive system in this environment will demand a lot of maintenance. The OPSIS DOAS system is different and provides plants with an accurate analyser that will operate with a minimum of maintenance. The OPSIS DOAS system is based on a non-contact method using an optical measurement path that can operate across the duct.

    By Opsis AB based in Furulund, SWEDEN.

  • Premium

    Urban air quality monitoring

    To measure air quality in the ambient air is a challenge. The monitoring site needs to be representative and not dependant on changes in local traffic. A large number of gaseous components need to be measured with high accuracy and high availability.

    By Opsis AB based in Furulund, SWEDEN.